Omron H7CC-AU Digital Counter

The Omron H7CC-AU Counter provides powerful preset and tachometer performance with dual outputsβ€”a reliable SPDT relay and a fast SPST transistorβ€”for flexible system control. Operating on 100–240 VAC, it features screw-terminal wiring, supports 30 Hz or 10 kHz speeds, and offers multiple UP/DOWN and quadrature input options. With dual reset inputs, a large 6-digit display, and non-volatile memory, it ensures dependable long-term accuracy. Suitable for single, dual, batch, and twin counting functions. Manufactured by Omron and listed under Omron Counter, this model is part of the versatile Omron H7CC Series.

BrandOmron
ProductCounters
Model NumberH7CC-AU

Omron H7CC-AU Digital Counter - Technical Specifications

SpecificationValue
Power consumptionApprox. 6.8 VA
External power supply12 VDC (Β±10%), 100 mA (except for H7CC-A8@ models) Refer to Precautions for Correct Use on page 61 for details
Max. counting speed30 Hz (minimum pulse width: 16.7 ms) or 10 kHz (minimum pulse width: 0.05 ms) (selectable) (ON/OFF ratio 1:1) *Common setting for CP1 and CP2
Counter Input modeIncrement (UP), decrement (DOWN), increment/decrement (UP/DOWN A (command input), UP/DOWN B (individual inputs), or UP/DOWN C (quadrature inputs)), UP/DOWN D (command input), UP/DOWN E (individual inputs), UP/DOWN E (quadrature inputs)
Input signalCP1, CP2, reset 1, and reset 2
Prescaling functionYes (0.001 to 99.999)
Decimal point adjustmentRefer to the separate table for tachometer function ratings
ClassificationPreset counter/ Tachometer
Configurationβ€’ 1-stage preset counter β€’ 2-stage preset counter β€’ Total and preset counter β€’ Batch counter β€’ Dual counter β€’ Twin counter β€’ Tachometer
Power supply voltage100 to 240 VAC
Mounting methodFlush mounting
External connectionsScrew terminals
OutputsContact output (SPDT) + Transistor output (SPST)
Digits6 digits -99999 to 999999 (-5 digits to +6 digits)
Operating voltage fluctuation range85% to 110% of rated supply voltage (12 to 48 VDC: 90% to 110%)
Auto-zero time/Startup time0.01 to 99.99 s
Sensor waiting timeExternal (minimum reset signal width: 1 ms or 20 ms, selectable), manual, and automatic reset (internal according to C, R, P, and Q mode operation)
Control output‒ Contact output: 3 A at 250 VAC/30 VDC, resistive load (cosφ=1), Minimum applied load: 10 mA at 5 VDC (failure level: P, reference value) ‒ Transistor output: NPN open collector, 100 mA at 30 VDC, Residual voltage: 1.5 VDC max. (approx. 1 V), Leakage current: 0.1 mA max.
Display7-segment, negative transmissive LCD Character height Count value: 10 mm (white) Set value: 6 mm (green)
Memory backupNon-volatile memory (overwrites: 100,000 times min.) that can store data for 10 years min.
Storage temperature range-10 to 55Β°C (-10 to 50Β°C if Counter/Tachometers are mounted side by side) (with no icing or condensation)
Operating humidity range25% to 85%
Input modeNo-voltage (NPN) input/voltage (PNP) input (switchable) No-voltage inputs: ON impedance: 1 kΞ© max. (Leakage current: 12 mA at 0 Ξ©) ON residual voltage: 3 V max. OFF impedance: 100 kΞ© min. Voltage input: High (logic) level: 4.5 to 30 VDC Low (logic) level: 0 to 2 VDC (Input resistance: approx. 4.7 kΞ©)
Degree of protectionIEC IP66 for panel surface only and only when Y92S-P6 Waterproof Packing is used
Case colorBlack (N1.5)

Disclaimer: IndMALL serves solely as a platform connecting buyers and vendors. It does not participate in pricing, payment, or delivery of goods.
Buyers are advised to verify all details and deal directly with vendors before finalizing any transaction.