Procurement managers rarely finalize H5CZ-L8ED without reviewing Omron Photoelectric Sensor, Omron H3Cr A8 Ac100 240 Dc100 125 and Autonics Timers, ensuring that the chosen component meets budget, compliance, and delivery conditions.
Omron H5CZ-L8ED Timer
The Omron H5CZ-L8ED Timer combines multifunction timing, instant contact output, and flicker/stopwatch modes for advanced control flexibility. It delivers ten selectable timing ranges, high immunity, and strong dielectric protection, ensuring stable performance in harsh automation environments. Its user-friendly LCD display and reliable SPDT output make configuration and monitoring simple. As a trusted industrial timing solution, it is manufactured by Omron, listed under Omron Timers, and forms an essential part of the flexible H5CZ Series lineup.
| Brand | Omron |
| Product Type | Timers |
| Model Number | H5CZ-L8ED |
Omron H5CZ-L8ED Timer - Technical Specifications
| Specification | Value |
|---|---|
| Rated supply voltage | 24 VAC (50/60 Hz) 12 to 24 VDC (Ripple 20% max.) |
| Operating voltage range | 12 to 24 VDC: 90% to 110% of rated supply voltage 24 VAC: 85 to 110% of rated supply voltage |
| Power consumption | Approx. 5.1 VA/Approx. 2.4 W |
| Time rangesοΌNumber of ranges) | 10 |
| Time ranges | 0.001 to 9.999 s 0.01 to 99.99 s 0.1 to 999.9 s 1 to 9999 s 0.1 to 999.9 min 1 to 9999 min 0.1 to 999.9 h 1 to 9999 h 1 s to 99 min 59 s 1 min to 99 h 59 min |
| Output modes | A-2: Power ON delay (β ‘) b: Repeat cycle (β ) E: Interval Z: ON/OFF-duty adjustable flicker toff: Flicker OFF start (β ) ton: Flicker ON start (β ) |
| Control output (Contact outputοΌ | Time-limit contact: SPDT, Instantaneous contact: SPDT Resistive load: 5 A at 250 VAC/30 VDC (cosΟ = 1) Minimum applicable load: 10 mA at 5 VDC (failure level: P Reference value) |
| Reset system | Power reset (depending on output mode)/Automatic reset (depending on output mode)/External reset/Manual reset |
| Timer mode | Elapsed time (UP) and remaining time (DOWN) (selectable) |
| Display method | LCD 4 digit |
| Character height | Present value: 10 mm Set value: 6 mm |
| Ambient temperature (Operating) | -10 to 55 β (with no freezing or condensation) When mount timer side by side: -10 to 50 β (with no freezing or condensation) |
| Ambient temperature (Storage) | -25 to 70 β (with no freezing or condensation) |
| Ambient humidity (Operating) | 25 to 85% |
| Accuracy of operating time | Power-ON start: Β±0.01% Β±0.05 s max. (The values are based on the set value.) Signal start: Β±0.005% Β±0.03 s max. (The values are based on the set value.) |
| Setting error | Power-ON start: Β±0.01% Β±0.05 s max. (The values are based on the set value.) Signal start: Β±0.005% Β±0.03 s max. (The values are based on the set value.) |
| Influence of voltage | Power-ON start: Β±0.01% Β±0.05 s max. (The values are based on the set value.) Signal start: Β±0.005% Β±0.03 s max. (The values are based on the set value.) |
| Influence of temperature | Power-ON start: Β±0.01% Β±0.05 s max. (The values are based on the set value.) Signal start: Β±0.005% Β±0.03 s max. (The values are based on the set value.) |
| Insulation Resistance | Between current carrying terminals and exposed non-current carrying metal parts: 100 MΞ© min. (at 500 VDC) Between non-continuous contacts: 100 MΞ© min. (at 500 VDC) |
| Dieelectric Strength | Between current carrying metal parts and non-current carrying metal parts: 2000 VAC 50/60 Hz 1 min Between control output and power supply: 2000 VAC 50/60 Hz 1 min Between non-continuous contacts: 1000 VAC 50/60 Hz 1 min |
| Impulse with stand voltage | Between power terminals: 1.0 kV Between current carrying terminals and exposed non-current carrying metal parts: 1.5 kV |
| Noise Immunity | Between power terminals: Β±1.5 kV Between input terminals: Β±600 kV square-wave noise by noise simulator, pulse width: 100 ns/1 Β΅s, 1-ns rise |
| Static Immunity | Mulfunction: 8 kV, Destruction: 15 kV |
| Vibration resistance | Destruction: 10 to 55 Hz, 0.75 mm single amplitude each in 3 directions for 2 h Malfunction: 10 to 55 Hz 0.35 mm single amplitude each in 3 directions for 10 min |
| Shock resistance | Destruction: 300 m/s2, 3 times each in 3 axes each directions Malfunction: 100 m/s2, 3 times each in 3 axes each directions |
| Life expectancy | Electrical: 100,000 operations min. (5 A at 250 VAC resistive load at 1800 operations/h, 23 β) Mechanical: 10 million operations min. (under no load at 1,800 operations/h, 23 β) |
| Degree of Protection | IEC IP66, UL508 Type 4X (indoors) (when using the Y92S-29 Waterproof Packing and Y92F-30 Flush Mounting Adapter) |
| Mounting method | Flush mounting / Surface mounting |
| External connection method | 8-pin round socket |
| Case Color | Light gray (Munsell 5Y7/1) |
| Accessory (sold separately) | Soft Cover: Y92A-48F1 Hard Cover: Y92A-48 Flush mounting adapter: Y92F-30 Waterproof packing: Y92S-29 |
| Weight | Main Unit: Approx. 105 g |
IndMALL Automation Dealing offers Omron ON/OFF-Duty Mode Timer, H5CZ-L8ED at unbeatable prices. The Main Technical Parameters of H5CZ-L8ED include 25 to 85%, Light gray (Munsell 5Y7/1), 8-pin round socket, Flush mounting / Surface mounting, 10, Key protect Switch, Present value: 10 mm, Set value: 6 mm & LCD 4 digit. Additionally, it provides Approx. 5.1 VA/Approx. 2.4 W, 12 to 24 VDC: 90% to 110% of rated supply voltage 24 VAC: 85 to 110% of rated supply voltage & 24 VAC (50/60 Hz) 12 to 24 VDC (Ripple 20% max.). Take the First Step with a Quote for your requirement of Omron ON/OFF-Duty Mode Timer. Choose us for unparalleled pricing and support over other Dealers & Distributors.