H5CX-L8E-N - Omron ICD 4 Digit SPDT Timer

Technical Specifications of H5CX-L8E-N Omron ICD 4 Digit SPDT Timer

BrandOmron
Product TypeTimers
ProductH5CX-L8E-N

Omron ICD 4 Digit SPDT Timer H5CX-L8E-N Technical Specifications:

SpecificationValue
Rated supply voltage100 to 240 VAC (50/60 Hz)
Operating voltage range85 to 110% of rated supply voltage
Power consumptionApprox. 6.2 VA
Time ranges(Number of ranges10
Time ranges0.001 to 9.999 s 0.01 to 99.99 s 0.1 to 999.9 s 1 to 9999 s 0.1 to 999.9 min 1 to 9999 min 0.1 to 999.9 h 1 to 9999 h 1 s to 99 min 59 s 1 min to 99 h 59 min
Input method-
No-voltage input (Solid state input)-
No-voltage input (Applicable two-wire sensor)-
Voltage input-
Output modesA-2: Power ON delay (β…‘) b: Repeat cycle (β… ) E: Interval Z: ON/OFF-duty adjustable flicker toff: Flicker OFF start (β… ) ton: Flicker ON start (β… )
Control output (Solid state output)Time-limit contact: SPDT, Instantaneous contact: SPDT Resistive load: 5 A at 250 VAC/30 VDC (cosφ = 1) Minimum applicable load: 10 mA at 5 VDC (failure level: P Reference value)
Reset systemPower reset (depending on output mode)/Automatic reset (depending on output mode)/External reset/Manual reset
Power resetMinimum power-opening time: 0.5 s (except for A-3, b-1, F, ton-1 and toff-1 mode)
Timer modeElapsed time (UP) and remaining time (DOWN) (selectable)
Display method7-segment negative transmissive LCD 4 digit
Character heightPresent value: 12 mm (Red, green or orange programmable) Set value: 6 mm (green)
Key protect methodKey protect Switch
Memory backup methodEEP-ROM (number of writes: 100,000 operations min., Service life: 10 years min.)
Ambient temperature (Operating)-10 to 55 ℃ (with no freezing or condensation) When mount timer side by side: -10 to 50 ℃ (with no freezing or condensation)
Ambient temperature (Storage)-25 to 70 ℃ (with no freezing or condensation)
Ambient humidity (Operating)25 to 85%
Accuracy of operating timePower-ON start: Β±0.01% Β±0.05 s max. (The values are based on the set value.) Signal start: Β±0.005% Β±3 ms max. (The values are based on the set value. The value is applied for a minimum pulse width of 1 ms.)
Setting errorPower-ON start: Β±0.01% Β±0.05 s max. (The values are based on the set value.) Signal start: Β±0.005% Β±3 ms max. (The values are based on the set value. The value is applied for a minimum pulse width of 1 ms.)
Influence of voltagePower-ON start: Β±0.01% Β±0.05 s max. (The values are based on the set value.) Signal start: Β±0.005% Β±3 ms max. (The values are based on the set value. The value is applied for a minimum pulse width of 1 ms.)
Influence of temperaturePower-ON start: Β±0.01% Β±0.05 s max. (The values are based on the set value.) Signal start: Β±0.005% Β±3 ms max. (The values are based on the set value. The value is applied for a minimum pulse width of 1 ms.)
Insulation resistanceBetween current carrying terminals and exposed non-current carrying metal parts: 100 MΞ© min. (at 500 VDC) Between non-continuous contacts: 100 MΞ© min. (at 500 VDC)
Dielectric strengthBetween current carrying metal parts and non-current carrying metal parts: 2000 VAC 50/60 Hz 1 min Between control output, and power supply/input circuit: 1000 VAC 50/60 Hz 1 min Between non-continuous contacts: 1000 VAC 50/60 Hz 1 min
Impulse withstand voltageBetween power terminals: 5 kV Between current carrying terminals and exposed non-current carrying metal parts: 5 kV
Noise immunityBetween power terminals: Β±1.5 kV square-wave noise by noise simulator, pulse width: 100 ns/1 Β΅s, 1-ns rise
Static immunityMulfunction: 8 kV, Destruction: 15 kV
Vibration resistanceDestruction: 10 to 55 Hz, 0.75 mm single amplitude each in 3 directions for 2 h Malfunction: 10 to 55 Hz 0.35 mm single amplitude each in 3 directions for 10 min
Shock resistanceDestruction: 300 m/s2, 3 times each in 3 axes each directions Malfunction: 100 m/s2, 3 times each in 6 directions
Life expectancyElectrical: 100,000 operations min. (5 A at 250 VAC resistive load at 1800 operations/h, 23 ℃) Mechanical: 10 million operations min. (under no load at 1,800 operations/h, 23 ℃)
Degree of protectionIEC IP66, UL508 Type 4X (indoors) (when using the Y92S-29 Waterproof Packing and Y92F-30 Flush Mounting Adapter)
Mounting methodFlush mounting / Surface mounting
External connection method8-pin round socket
Case colorBlack (Munsell N1.5)
Attachment-
Accessory (sold separately)Soft Cover: Y92A-48F1 Hard Cover: Y92A-48 Flush mounting adapter: Y92F-30/Y92F-45/Y92F-38 Waterproof packing: Y92S-29 Replacement Front Panel: Y92P-CXT4S/Y92P-CXT4G/Y92P-CXT4B
WeightMain Unit: Approx. 115 g
Mail Us for your needs in Omron ICD 4 Digit SPDT Timer, H5CX-L8E-N with budget-friendly prices. The Main Technical Parameters of H5CX-L8E-N include 100 to 240 VAC (50/60 Hz), 85 to 110% of rated supply voltage, Approx. 6.2 VA, 10, 7-segment negative transmissive LCD 4 digit, -, - & Key protect Switch. Additionally, it provides Black (Munsell N1.5), Flush mounting / Surface mounting & 8-pin round socket. Customize Your Experience with a Quote for your requirement of Omron ICD 4 Digit SPDT Timer. Experience the difference with our competitive pricing and superior support over other Suppliers.