Omron H5CX-BWSD-N Timer
The Omron H5CX-BWSD-N Timer is a compact industrial timing unit designed to operate within 85 to 110% of rated supply voltage.It features 4 time ranges along with a No-voltage (NPN)/Voltage (PNP) input (selectable) input method. Its 7-segment negative transmissive LCD 6 digit provides clear visibility, while static immunity of 8 kV mulfunction and 15 kV destruction ensures reliable operation. Manufactured by Omron, listed under Omron Timers, this model belongs to the H5CX Series and supports Flush mounting with Screw terminal connections in a Black (Munsell N1.5) case.

| Brand | Omron |
| Product | Timers |
| Model Number | H5CX-BWSD-N |
Omron H5CX-BWSD-N Timer - Technical Specifications
| Specification | Value |
|---|---|
| Rated supply voltage | 12 to 24 VDC (Ripple 20% max.) |
| Operating voltage range | 85 to 110% of rated supply voltage |
| Connection method | Screw terminal |
| Mounting method | Flush mounting |
| Power consumption | Approx. 2.3 W |
| Time ranges (Number of ranges) | 4 |
| Time ranges | 0.01 to 9999.99 s 0.1 to 99999.9 min 0.1 to 99999.9 h 1 s to 99 h 59 min 59 s |
| Input method | No-voltage (NPN)/Voltage (PNP) input (selectable) |
| Output modes | A: Signal ON delay F-1: Cumulative |
| Reset system | Power reset (A mode)/External reset/Manual reset |
| Timer mode | Elapsed time (UP) |
| Display method | 7-segment negative transmissive LCD 6 digit |
| Character height | Present value: 12 mm (Red, green or orange programmable) Set value: 6 mm (green) |
| Ambient temperature range | -10 to 55 β (with no freezing or condensation) When mount timer side by side: -10 to 50 β (with no freezing or condensation) |
| Ambient humidity (Operating) | 25 to 85% |
| Accuracy of operating time | Power-ON start: Β±0.01% Β±0.05 s max. (The values are based on the set value.) Signal start: Β±0.005% Β±3 ms max. (The values are based on the set value. The value is applied for a minimum pulse width of 1 ms.) |
| Setting error | Power-ON start: Β±0.01% Β±0.05 s max. (The values are based on the set value.) Signal start: Β±0.005% Β±3 ms max. (The values are based on the set value. The value is applied for a minimum pulse width of 1 ms.) |
| Influence of voltage | Power-ON start: Β±0.01% Β±0.05 s max. (The values are based on the set value.) Signal start: Β±0.005% Β±3 ms max. (The values are based on the set value. The value is applied for a minimum pulse width of 1 ms.) |
| Influence of temperature | Power-ON start: Β±0.01% Β±0.05 s max. (The values are based on the set value.) Signal start: Β±0.005% Β±3 ms max. (The values are based on the set value. The value is applied for a minimum pulse width of 1 ms.) |
| Insulation resistance | Between current carrying terminals and exposed non-current carrying metal parts: 100 MΞ© min. (at 500 VDC) |
| Dielectric strength | Between current carrying metal parts and non-current carrying metal parts: 2000 VAC 50/60 Hz 1 min Between control output, and power supply/input circuit: 1000 VAC 50/60 Hz 1 min Between non-continuous contacts: 1000 VAC 50/60 Hz 1 min |
| Impulse withstand voltage | Between power terminals: 1.0 kV Between current carrying terminals and exposed non-current carrying metal parts: 1.5 kV |
| Noise immunity | Between power terminals: Β±480 kV Between input terminals: Β±600 kV square-wave noise by noise simulator, pulse width: 100 ns/1 Β΅s, 1-ns rise |
| Static immunity | Mulfunction: 8 kV, Destruction: 15 kV |
| Vibration resistance | Destruction: 10 to 55 Hz, 0.75 mm single amplitude each in 3 directions for 2 h Malfunction: 10 to 55 Hz 0.35 mm single amplitude each in 3 directions for 10 min |
| Shock resistance | Destruction: 300 m/s2, 3 times each in 3 axes each directions Malfunction: 100 m/s2, 3 times each in 6 directions |
| Degree of protection | IEC IP66, UL508 Type 4X (indoors) (when using the Y92S-29 Waterproof Packing and Y92F-30 Flush Mounting Adapter) |
| Case color | Black (Munsell N1.5) |
| Accessory (sold separately) | Soft Cover: Y92A-48F1 Hard Cover: Y92A-48 Flush mounting adapter: Y92F-30/Y92F-45/Y92F-38 Waterproof packing: Y92S-29 Replacement Front Panel: Y92P-CXT4S/Y92P-CXT4G/Y92P-CXT4B |
| Ambient temperature range | -10 to 55 β (with no freezing or condensation) When mount timer side by side: -10 to 50 β (with no freezing or condensation) |
| No-voltage input (Solid state input) | Short-circuit (ON) impedance: 1 kΞ© max. (Leakage current (0 Ξ©): Approx. 12 mA) Short-circuit (ON) residual voltage: 3 V max. Open circuit impedance: 100 kΞ© min. (The DC voltage must be 30 VDC max.) |
| No-voltage input (Contact input) | Use contact which can adequately switch 5 mA at 10 V |
| No-voltage input (Applicable two-wire sensor) | Leakage current: 1.5 mA max. Switching capacities: 5 mA min. Residual voltage: 3.0 VDC max. Operating voltage: 10 VDC |
| Voltage input | High level: 4.5 to 30 VDC Low level: 0 to 2 VDC (Input resistance 4.7 kΞ©) |
| Control output (Solid state output) | 2 pointTransistor output (NPN open collector) Switching capacities: 30 VDC max., 100 mA max. Residual voltage: 1.5 V (Capacity value 1 V) Leakage current: 0.1 mA max. |
| Power reset | Minimum power-opening time: 0.5 s (except for A-3, b-1, F, ton-1 and toff-1 mode) |
| Key protect method | Key protect Switch |
| Memory backup method | EEP-ROM (number of writes: 100,000 operations min., Service life: 10 years min.) |
| Attachment | Flush mounting adapter, waterproof packing, label for DIP switch settings, terminal covers |
| Weight | Main Unit: Approx. 105 g |