+91 79955 44066
IndMALL: B2B Marketplace - We Connect Buyers & Sellers for Industrial Products

Omron H3FA-SBU DC5/6 Solid-state Timer

The Omron H3FA-SBU DC5/6 Timer is a dependable Solid-state Timer featuring four timing ranges to meet essential automation timing requirements. It operates in both One shot output and Signal OFF delay modes, enabling flexible and accurate timing responses. With a reliable Transistor output and quick 10 ms max. reset time, it ensures rapid recovery within control circuits. Its PCB terminal connection supports direct board mounting for compact designs. Manufactured by Omron, listed under Omron Timers, and belonging to the H3FA Series.

BrandOmron
ProductTimers
Model NumberH3FA-SBU DC5/6

Omron H3FA-SBU DC5/6 Solid-state Timer - Technical Specifications

SpecificationValue
Rated power supply voltage5/6 VDC Ripple 3% max.
Allowable voltage variable rangefor 5 VDC: 90 to 110% of the power supply voltage/for 6 VDC: 85 to 110% of the power supply voltage
Number of time ranges4
Operation modeOne shot output, Signal OFF delay
Control output (Type)Transistor output
Control output (Contact output)150 mA max. at 30 VDC, ON residual voltage: 1.0 V max.
Operating resettingInstantaneous operation, time-limit resetting/external resetting
Connection methodPCB terminal
Power consumptionApprox. 80 mW
Ambient temperature rangeOperating: -10 to 55 ℃ (with no icing) Storage: -25 to 65 ℃ (with no icing)
Accuracy of operating time±0.5% FS max.
Setting error0 to +30% FS max. (at 20 ℃, rated voltage)
Influence of voltage±2% FS max.
Influence of temperature±5% FS max.
Insulation resistance100 MΩ min. (at 500 VDC)
Dielectric strengthBetween control output terminals and operating circuit: 1,500 VAC 50/60 Hz 1 min Between non-continuous contacts: 1,000 VAC 50/60 Hz 1 min
Vibration resistanceDestruction: 10 to 55 Hz, 0.375 mm single amplitude each in 3 directions for 2 h Malfunction: 10 to 55 Hz, 0.25 mm single amplitude each in 3 directions for 10 min
Shock resistanceDestruction: 1,000 m/s2, 3 times each in 6 directions Malfunction: 100 m/s2, 3 times each in 6 directions
Ambient temperature rangeOperating: -10 to 55 ℃ (with no icing) Storage: -25 to 65 ℃ (with no icing)
Ambient humidity rangeOperating: 35 to 85%
Reset time10 ms max.
Life expectancy (relay output)-
WeightApprox. 10 g

Disclaimer: IndMALL serves solely as a platform connecting buyers and vendors. It does not participate in pricing, payment, or delivery of goods.
Buyers are advised to verify all details and deal directly with vendors before finalizing any transaction.