Omron H3DK-G AC/DC24-240 Timer

The Omron H3DK-G AC/DC24-240 Timer is designed for precise timing control with an allowable voltage variable range of 85 to 110% of the power supply voltage. The model supports a reset voltage within 10% max. of rated supply voltage and offers 2 selectable time ranges for flexible operation and a Terminal blocks connections. Manufactured by Omron, listed under Omron Timers, and part of the H3DK Series.

BrandOmron
ProductTimers
Model NumberH3DK-G AC/DC24-240

Omron H3DK-G AC/DC24-240 Timer - Technical Specifications

SpecificationValue
Rated power supply voltage24 to 240 VAC 50/60 Hz 24 to 240 VDC Ripple 20% max.
Allowable voltage variable range85 to 110% of the power supply voltage
Reset voltage10% max. of rated supply voltage
Number of time ranges2
Operation modeStar-delta
Control output (Type)Time-limit: SPDT (Start operation circuit) SPDT (Delta operation circuit)
Control output (Contact output)Resistive load: 250 VAC 5 A (cosφ=1)/5 A at 30 VDC/0.5 A max. at 125 VDC Minimum applicable load: 10 mA at 5 VDC (failure level: P Reference value)
Operating resettingTime-limit operation/Self-reset
Connection methodTerminal blocks
Power consumptionApprox. 6.6 VA (at 240 VAC)
Ambient temperature rangeOperating: -20 to 55 ℃ (with no icing) Storage: -40 to 70 ℃ (with no icing)
Accuracy of operating timeΒ±1% FS max
Setting errorΒ±10% FS Β±0.05 s max.
Influence of voltageΒ±0.5% FS max.
Influence of temperatureΒ±2% FS max.
Insulation resistance100 MΞ© min. (at 500 VDC)
Dielectric strengthBetween current carrying metal parts and non-current carrying metal parts: 2,000 VAC 50/60 Hz 1 min Between control output terminals and operating circuit: 2,000 VAC 50/60 Hz 1 min Between non-continuous contacts: 1,000 VAC 50/60 Hz 1 min
Impulse withstand voltageBetween power terminals: 5 kV Between current carrying terminals and exposed non-current carrying metal parts: 5 kV
Noise immunityΒ±1.5 kV square-wave noise by noise simulator (pulse width: 100 ns/1 Β΅s, 1-ns rise)
Static immunityMulfunction: 4 kV, Destruction: 8 kV
Vibration resistanceDestruction: 10 to 55 Hz, 0.75 mm single amplitude each in 3 directions for 2 h Malfunction: 10 to 55 Hz, 0.5 mm single amplitude each in 3 directions for 10 min
Shock resistanceDestruction: 1,000 m/s2, 3 times each in 6 directions Malfunction: 100 m/s2, 3 times each in 6 directions
Degree of protectionIP30 (Terminal Block: IP20)
Ambient temperature rangeOperating: -20 to 55 ℃ (with no icing) Storage: -40 to 70 ℃ (with no icing)
Ambient humidity rangeOperating: 25 to 85%
Life expectancy (relay output)Electrical: 100,000 operations min. (5 A at 250 VAC, resistive load at 360 operations/h) Mechanical: 10 million operations min. (under no load at 1,800 operations/h)
Star-delta transfer timeselectable from 0.05 s, 0.1 s, 0.25 s and 0.5 s
AccessoriesUser label
WeightApprox. 120 g