Engineers reviewing design requirements often place {Series} models beside Moxa Ethernet Switch, Moxa Eds 205 and Pressure Gauge Manufacturers In Gujarat, clarifying technical differences that affect long-term reliability.
CN2600 Series: Moxa 8/16-port RS-232/422/485 Terminal Server, Dual-LAN
Technical Specifications of Moxa 8 and 16-port RS-232/422/485 Terminal Servers with Dual-LAN Redundancy CN2600 Series:

| Databits | 5, 6, 7, 8 |
| Stop Bits | 1, 1.5, 2 |
| Input Voltage | -HV models: 110 VDC (88 to 300 VDC), All other models: 100 to 240 VAC, 50/60 Hz |
| Magnetic Isolation Protection | 1.5 kV (built-in) |
Moxa 8 and 16-port RS-232/422/485 Terminal Servers with Dual-LAN Redundancy CN2600 Series Technical Specifications:
| Specification | Value |
|---|---|
| 10/100BaseT(X) Ports (RJ45 connector) | 2 |
| Magnetic Isolation Protection | 1.5 kV (built-in) |
| Configuration Options | CN2610-8/CN2610-16: Serial Console, Telnet Console, Windows Utility, Device Search Utility (DSU), CN2650-8/CN2650-16/CN2600-2AC models: Serial Console, Telnet Console, Windows Utility, Device Search Utility (DSU), Web console (HTTP/HTTPS) |
| Management | ARP, BOOTP, DDNS, DHCP Client, DNS, HTTP, IPv4, SMTP, SNMPv1/v2c/v3, TCP/IP, Telnet, UDP, ICMP, SLIP |
| Authentication | Local database (password only), RADIUS |
| Encryption | HTTPS, AES-128, AES-256, HMAC, RSA-1024, SHA-1 |
| Security Protocols | SNMPv3, SSHv2 |
| Baudrate | 50 bps to 921.6 kbps |
| Data Bits | 5, 6, 7, 8 |
| Stop Bits | 1, 1.5, 2 |
| Parity | None, Even, Odd, Space, Mark |
| Flow Control | None, RTS/CTS, DTR/DSR, XON/XOFF |
| RS-485 Data Direction Control | ADDC® (automatic data direction control) |
| RS-232 | TxD, RxD, RTS, CTS, DTR, DSR, DCD, GND |
| Input Voltage | -HV models: 110 VDC (88 to 300 VDC), All other models: 100 to 240 VAC, 50/60 Hz |
| Operating Temperature | Standard Models: 0 to 55°C (32 to 131°F), CN2650-8-2AC-T/CN2650-16-2AC-T: -40 to 75°C (-40 to 167°F), CN2650I-8-HV-T/CN2650I-16-HV-T: -40 to 85°C (-40 to 185°F) |
| EMC | CN2650I models: EN 55032/35, All other models: EN 55032/24 |
| Safety | - |
Call us for Moxa 8 and 16-port RS-232/422/485 Terminal Servers with Dual-LAN Redundancy CN2600 Series at the best rates. Technical Attributes of CN2600 Series are baud rate range from 50 bps to 921.6 kbps. These sensors accommodate data bits settings of 5, 6, 7, 8 and stop bits of 1, 1.5, 2 ensuring flexibility in communication protocols. Flow control options include None, RTS/CTS, DTR/DSR, XON/XOFF with parity choices of None, Even, Odd, Space, Mark. Operating on an input voltage range of -HV models: 110 VDC (88 to 300 VDC), All other models: 100 to 240 VAC, 50/60 Hz, the sensors are housed in a durable Metal casing designed for industrial environments. Standard models operate in temperatures from Standard Models: 0 to 55°C (32 to 131°F), CN2650-8-2AC-T/CN2650-16-2AC-T: -40 to 75°C (-40 to 167°F), CN2650I-8-HV-T/CN2650I-16-HV-T: -40 to 85°C (-40 to 185°F). These sensors meet EMC standards CN2650I models: EN 55032/35, All other models: EN 55032/24. Unlock Exclusive Pricing with a Quote for your requirement of Moxa 8 and 16-port RS-232/422/485 Terminal Servers with Dual-LAN Redundancy. Trust in our ability to provide more advantageous pricing and dedicated support beyond other other Dealers.