Technical Specifications of DTB4896CVE Delta Outputs DC Current and Pulse Voltage

BrandDelta
Product TypeTemperature Controller
ProductDTB4896CVE

Delta Outputs DC Current and Pulse Voltage DTB4896CVE Technical Specifications:

SpecificationValue
Panel Size (WΓ—H)1/8 DIN W48 Γ— H96mm
Input VoltageAC100 ~ 240V, 50/60Hz; DC24VΒ±10%
Operation Voltage RangeRated voltage: AC 85% ~ 110%; DC 90 ~ 110%
Power Consumption5VA max.
Memory ProtectionEEPROM 4K bit (non-volatile memory (number of writes: 100,000)
Display Method2 line x 4 character 7-segment LED display Process value (PV): Red color, Set point (SV): Green color
Sensor TypeThermocouple: K, J, T, E, N, R, S, B, L, U, TXK 3-wire Platinum RTD: Pt100, JPt100 Analog input: 0 ~ 5V, 0 ~ 10V, 0 ~ 20 m A, 4 ~ 20 m A, 0 ~ 50mV
Control ModePID, ON/OFF, Manual or PID program control (Ramp/Soak control)
Control OutputRelay output: SPDT (SPST: 1/16 DIN and 1/32 DIN size), Max. load 250VAC, 5A resistive load Voltage pulse output: DC 14V, Max. output current 40mA Current output: DC 4 ~ 20m A output (Load resistance: Max. 600) Linear voltage output: 0 ~ 10V
Display Accuracy0 or 1 digit to the right of the decimal point (selectable)
Sampling RateAnalog input: 150 msec/ per scan Thermocouple or Platinum RTD: 400 msec/per scan
RS-485 CommunicationMODBUS ASCII / RTU communication protocol
Vibration Resistance10 to 55Hz, 10m/s2 for 10min, each in X, Y and Z directions
Shock ResistanceMax. 300m/ s2, 3 times in each 3 axes, 6 directions
Ambient Temperature0oC ~ +50oC
Storage Temperature-20oC ~ +65oC
Altitude2,000m or less
Relative Humidity35% ~ 80% (non-condensing)
Panel Protection LevelIP65
1st Output Group SelectionR: Relay output, SPDT (SPST: 1/16 DIN and 1/32 DIN size), 250VAC, 5A V: Voltage pulse output, 14V +10% ~ -20% (Max. 40mA) C: DC current output , 4 ~ 20mA L: Linear voltage output, 0 ~ 10VDC
2nd Output Group SelectionR: Relay output, SPDT (SPST: 1/16 DIN and 1/32 DIN size), 250VAC, 5A V: Voltage pulse output, 14V +10% ~ -20% (Max. 40mA)
EVENT inputs / CT function (optional)None: No EVENT input , No CT (Current transformer) E: EVENT input is provided, No CT (Current transformer) T: CT (Current transformer) is provided, No EVENT input V: Valve control
IndMALL Offers Delta Outputs DC Current and Pulse Voltage, DTB4896CVE at economical Choices. Product Tech Specs of DTB4896CVE includes 1/8 DIN W48 Γ— H96mm, 5VA max., AC100 ~ 240V, 50/60Hz; DC24VΒ±10%, Rated voltage: AC 85% ~ 110%; DC 90 ~ 110%. And It Includes PID, ON/OFF, Manual or PID program control (Ramp/Soak control), 2 line x 4 character 7-segment LED display Process value (PV): Red color, Set point (SV): Green color, EEPROM 4K bit (non-volatile memory (number of writes: 100,000). Now's the Time to Secure a Quote for your requirement of Delta Outputs DC Current and Pulse Voltage. Trust in our superior pricing and more dedicated support over other Distributors.

Disclaimer: IndMALL serves solely as a platform connecting buyers and vendors. It does not participate in pricing, payment, or delivery of goods.
Buyers are advised to verify all details and deal directly with vendors before finalizing any transaction.