Many procurement teams check DT320CA-R211 against Masibus Temperature Controller, Delta VFD and Rs 485 Controller before signing purchase orders, verifying quality, compliance, and after-sales support availability.
DT320CA-R211 - Delta 80 ~ 260VAC, Event Input2
Technical Specifications of DT320CA-R211 Delta 80 ~ 260VAC, Event Input2
| Brand | Delta |
| Product Type | Temperature Controller |
| Product | DT320CA-R211 |
Delta 80 ~ 260VAC, Event Input2 DT320CA-R211 Technical Specifications:
| Specification | Value |
|---|---|
| Panel Size (W×H) | 4848 1/16 DIN W48 × H48mm |
| Input Voltage | 80 ~ 260Vac 50/60Hz; 24Vac 50/60Hz ±10%; 24 Vdc ±10% |
| Power Consumption | 8VA max. |
| Display Method | LCD display. Process value (PV): Yellow color, Set point (SV): Green color |
| Alarm Output Type | Relay output: Max. load 250Vac, 3A resistive load |
| Display Accuracy | 0 or 1 digit to the right of the decimal point (selectable) |
| Sampling Rate | Analog input: 0.1 sec/ per scan; Thermocouple or Platinum RTD: 0.1 sec/per scan |
| Control Mode | PID, PID program control (Ramp/Soak control), FUZZY, Self-tuning, Manual and On/FF |
| Sensor Type | Thermocouple: K, J, T, E, N, R, S, B, L, U, TXK (Thermal couple measuring location are not intended to be directly connected to the MAINS supply.) 3-wire Platinum RTD: Pt100, JPt100 Resistance: Cu50, Ni120 Analog input: 0 ~ 5Vdc, 0 ~ 10Vdc, 0 ~ 20mA, 4 ~ 20mA, 0 ~ 50mVdc |
| Control Output | Relay output: Max. load 250Vac, 5A resistive load Voltage pulse output: 12Vdc, Max. output current 40mA Current output: DC 4 ~ 20m A output (Load resistance: Max. 500Ω) Analog voltage output: 0 ~ 10Vdc |
| Vibration Resistance | 10 to 55Hz, 10m/s2 for 10min, each in X, Y and Z directions |
| Shock Resistance | Max. 300m/ s2 , 3 times in each 3 axes, 6 directions |
| Ambient Temperature | 0°C ~ +50°C |
| Storage Temperature | -20°C ~ +65°C |
| Altitude | Max. 2000m |
| Relative Humidity | 35% ~ 80% RH(non-condensing) |
| Panel protection level | IP66 |
Get A Quote for Delta 80 ~ 260VAC, Event Input2, DT320CA-R211 at the best price. Here are the brief Technical Specifications of DT320CA-R211: Analog input: 0.1 sec/ per scan; Thermocouple or Platinum RTD: 0.1 sec/per scan, 0 or 1 digit to the right of the decimal point (selectable), Relay output: Max. load 250Vac, 3A resistive load
, LCD display. Process value (PV): Yellow color, Set point (SV): Green color . And it offers 8VA max., 80 ~ 260Vac 50/60Hz; 24Vac 50/60Hz ±10%; 24 Vdc ±10%, 4848 1/16 DIN W48 × H48mm. It's Time to get a Quote for your requirement of Delta 80 ~ 260VAC, Event Input2. We guarantee unmatched pricing and unparalleled support compared to other Distributors.