Delta DRP024V480W3BN 24V 20A DIN Rail Power Supply
Delta DRP024V480W3BN is a 20Amp 24V DIN Rail Power Supply designed for industrial automation, high-power control panels, and systems requiring dependable 24V DC output. Supporting a nominal input voltage of 3 x 400–500Vac with a wide input range of 3 x 320–600Vac, this unit delivers stable voltage for PLCs, relays, sensors, and other industrial devices. Its DIN rail mounting ensures structured and space-efficient installation in industrial enclosures. Manufactured by Delta Industrial Automation, this model is part of the Delta Power Supply Solutions category, and belongs to the Delta DIN Rail CliQ II Series, providing reliable 480W DC power for automation and process control applications.

| Brand | Delta |
| Product Type | SMPS |
| Product | DRP024V480W3BN |
Delta 20Amp DIN Rail Power Supply DRP024V480W3BN Technical Specifications:
| Specification | Value |
|---|---|
| Output Current | 20A |
| Output Voltage | 24V |
| Output Voltage Adjustment Range | 24-28 Vdc |
| Output Power | 480W |
| Line Regulation | < 0.5% (@ 3 x 320-600Vac input, 100% load) |
| Load Regulation | < 1.0% (@ 3 x 320-600Vac input, 0-100% load) |
| PARD | < 150mVpp |
| Start-up Time | < 1,000ms @ nominal input (100% load) |
| Hold-up Time | > 20ms @ 3 x 400Vac & 3 x 500Vac (100% load) |
| Dynamic Response (Overshoot & Undershoot O/P Voltage) | ± 5% @ 3 x 320-600Vac input, 10-90% load (Slew Rate: 0.1A/μs, 50% duty cycle @ 5Hz to 1KHz) |
| Start-up with Capacitive Loads | 10,000µF Max |
| Rise Time | < 100ms @ nominal input (100% load) |
| Nominal Input Voltage | 3 x 400-500Vac |
| Input Voltage Range | 3 x 320-600Vac |
| Nominal Input Frequency | 50-60Hz |
| Input Frequency Range | 47-63Hz |
| DC Input Voltage Range | 450-800Vdc |
| Input Current | < 1.00A @ 3 x 400Vac < 0.75A @ 3 x 500Vac |
| Efficiency at 100% load | > 91.0% @ 3 x 400Vac & 3 x 500Vac |
| Inrush Current | < 50A @ 3 x 400Vac & 3 x 500Vac |
| Power Factor at 100% load | > 0.95 @ 3 x 400Vac, > 0.94 @ 3 x 500Vac |
| Leakage Current | < 3.5mA @ 3 x 600Vac |
| Power Dissipation | 0% load: < 5.0W @ 3 x 400Vac & 3 x 500Vac 100% load: < 47.0W @ 3 x 400Vac & 3 x 500Vac |
| Case Chassis / Cover | Aluminium |
| Indicator | Green LED (DC OK) |
| Cooling System | Convection |
| Input Terminal | 4 Pins (Rated 600V/35A) |
| Output Terminal | 4 Pins (Rated 300V/30A) |
| Noise Sound Pressure Level (SPL) | < 40dBA |
| Mounting Rail | Standard TS35 DIN Rail in accordance with EN 60715 |
| Wire | Input: AWG 18-8 Output: AWG 12-10 |
| Unit Weight | 1.35 kg (2.98 lb) |
| Operating Temperature | -25°C to +80°C (Cold Start at -40°C) |
| Storage Temperature | -40°C to +85°C |
| Power De-rating | Vertical: > 50°C de-rate power by 2.5% / °C, > 70°C de-rate power by 5% / °C |
| Operating Humidity | 5 to 95% RH (Non-Condensing) |
| Shock Test (Non-Operating) | IEC 60068-2-27, 30G (300m/S for a duration of 18ms, 3 times per direction, 6 times in total |
| Vibration (Non-Operating) | IEC 60068-2-6, 10Hz to 500Hz @ 30m/S² (3G peak); 60 min per axis for all X, Y, Z direction |
| Operating Altitude | 0 to 2,500 Meters (8,200 ft.) for ITE application 0 to 2,000 Meters (6,560 ft.) for Industrial application |
| Pollution Degree | 2 |
| Bump Test (Operating) | IEC 60068-2-29, Half Sine Wave: 10G for a duration of 11ms, 1,000 times per direction, 6,000 times in total |
| Over Voltage Category | III According to IEC/EN 62477-1 / EN 60204-1 (clearance and creepage distances) and IEC 62103 (safety part) |
The Delta DRP024V480W3BN 480W 24V DIN Rail Power Supply is engineered for high-demand industrial applications that require a stable 24V DC output at 20A. Built for continuous operation, it delivers precise line and load regulation, low ripple, and efficient performance across full load conditions. With input and output terminals rated at 600V/35A and 300V/30A, it ensures secure connections for industrial-grade devices. Its compact DIN rail form factor allows organized installation in control panels, optimizing space and accessibility. The unit operates efficiently across a wide temperature range of -25°C to +80°C and can be safely stored from -40°C to +85°C, making it suitable for harsh environments. Its convection cooling system ensures silent operation, and three-phase input capability supports stable performance even under high-power industrial conditions. Ideal for powering PLCs, relays, sensors, motors, and other critical control circuits, it provides dependable DC output for process automation. IndMALL offers competitive pricing, instant quotations, and responsive support, giving superior value and service compared to other suppliers. The Delta DRP024V480W3BN combines industrial-grade reliability, robust construction, and energy-efficient design, making it a trusted solution for DIN rail-mounted automation and control systems, improving uptime, productivity, and long-term operational stability.