Delta DRP-24V100W1NN 3.8A 91W DIN Rail Power Supply
Delta DRP-24V100W1NN is a 3.8A 91W DIN Rail Power Supply engineered for industrial automation, control panels, and embedded electronics that require stable DC output. Supporting a nominal input voltage of 100-240Vac with a wide input range of 85-264Vac, this unit ensures reliable operation in diverse industrial conditions. Its DIN Rail mounting provides a clean and organized installation in control cabinets. Manufactured by Delta industrial automation, this model is part of the Delta power supply solutions category and belongs to the Delta DIN Rail CliQ II Series, delivering dependable 24V DC power for automation systems, embedded devices, and industrial control panels.

| Brand | Delta |
| Product Type | SMPS |
| Product | DRP-24V100W1NN |
Delta 3.8A 91W DIN Rail Power Supply DRP-24V100W1NN Technical Specifications:
| Specification | Value |
|---|---|
| Output Current | 3.8A |
| Output Voltage | 24V |
| Output Voltage Adjustment Range | 22-24Vdc |
| Output Power | 91W |
| Line Regulation | < 0.5% (@ 85-264Vac input, 100% load) |
| Load Regulation | < 1.0% at -25°C to +25°C < 2.0% at +25°C to +50°C (@ 85-264Vac input, 0-100% load) |
| PARD | < 150mVpp |
| Start-up Time | < 2,000ms @ nominal input (100% load) |
| Hold-up Time | > 20ms @ 115Vac, > 30ms @ 230Vac (100% load) |
| Dynamic Response (Overshoot & Undershoot O/P Voltage) | ± 5% @ 85-264Vac input, 0-100% load (Slew Rate: 0.1A/μs, 50% duty cycle @ 5Hz to 1kHz) |
| Start-up with Capacitive Loads | 8,000μF Max |
| Rise Time | < 100ms @ nominal input (100% load) |
| Nominal Input Voltage | 100-240Vac |
| Input Voltage Range | 85-264Vac |
| Nominal Input Frequency | 50-60Hz |
| Input Frequency Range | 47-63Hz |
| DC Input Voltage Range | 120-375Vdc |
| Input Current | < 1.00A @ 115Vac, < 0.53A @ 230Vac |
| Efficiency at 100% load | > 88.0% @ 115Vac, > 89.0% @ 230Vac |
| Inrush Current | < 30A @ 115Vac, < 60A @ 230Vac |
| Power Factor at 100% load | > 0.99 @ 115Vac, > 0.94 @ 230Vac |
| Leakage Current | < 0.5mA @ 240Vac |
| Power Dissipation | 0% load: < 0.7W @ 115Vac, < 0.8W @ 230Vac 100% load: < 12.4W @ 115Vac, < 11.2W @ 230Vac |
| Case Chassis / Cover | Aluminium |
| Indicator | Green LED (DC OK) |
| Cooling System | Convection |
| Input Terminal | 3 Pins (Rated 600V/35A) |
| Output Terminal | 4 Pins (Rated 300V/28A) |
| Noise Sound Pressure Level (SPL) | < 40dBA |
| Mounting Rail | Standard TS35 DIN Rail in accordance with EN 60715 |
| Wire | Input / Output: AWG 18-12 |
| Unit Weight | 0.60 kg (1.32 lb) |
| Operating Temperature | -25°C to +80°C (Cold Start at -40°C) |
| Storage Temperature | -40°C to +85°C |
| Power De-rating | Vertical: > 50°C de-rate power by 2.5% / °C, > 70°C de-rate power by 4% / °C Horizontal: > 40°C de-rate power by 2.5% / °C |
| Operating Humidity | 5 to 95% RH (Non-Condensing) |
| Shock Test (Non-Operating) | IEC 60068-2-27, 30G (300m/S²) for a duration of 18ms, 1 times per direction, 2 times in total |
| Vibration (Non-Operating) | IEC 60068-2-6, 10Hz to 500Hz @ 30m/S² (3G peak); 60 min per axis for all X, Y, Z direction |
| Operating Altitude | 0 to 2,500 Meters (8,200 ft) |
| Pollution Degree | 2 |
| Bump Test (Operating) | IEC 60068-2-29, Half Sine Wave: 10G for a duration of 11ms, 1,000 times per direction, 6,000 times in total |
| Over Voltage Category | III According to IEC/EN 62477-1 / EN 60204-1 (clearance and creepage distances) and IEC 62103 (safety part) |
The Delta DRP-24V100W1NN 3.8A 91W DIN Rail Power Supply is ideal for industrial control cabinets, factory automation panels, and embedded systems requiring stable 24V DC power. With a 3.8A current rating and 91W power capacity, it delivers reliable output for multiple devices while maintaining operational efficiency. Its wide input voltage compatibility ensures consistent performance even under varying industrial power conditions.
Equipped with secure input and output terminals, this DIN Rail unit allows rapid and reliable connections. The Green LED DC OK indicator provides quick visual confirmation of operational status, simplifying monitoring and maintenance. Its compact form factor allows neat installation in control cabinets while providing industrial-grade durability. The operating temperature ranges from -25°C to +80°C with cold start capability at -40°C, and storage temperatures from -40°C to +85°C ensure the unit withstands harsh environments.
Engineers, system integrators, and industrial operators seeking dependable 3.8A 91W DIN Rail solutions will benefit from the Delta DRP-24V100W1NN’s consistent performance, energy efficiency, and industrial reliability. IndMALL provides competitive pricing, instant quotes, and responsive support, offering superior value over other suppliers. Its robust design, compact size, and dependable operation make it ideal for automation systems, embedded electronics, and control panels, improving productivity, minimizing downtime, and ensuring long-term reliability in industrial setups.