Technical Specifications of Delta DRL-48V480W1ENA 480W 48V DIN Rail Power Supply

BrandDelta
Product TypeSMPS
ProductDRL-48V480W1ENA

Delta 480W 48V DIN Rail Power Supply DRL-48V480W1ENA Technical Specifications:

SpecificationValue
Output Current10A
Output Voltage48V
Output Voltage Adjustment Range48-55 Vdc
Output Power480W
Output Voltage Range-
Line Regulation± 0.5% @ 115 Vac & 230 Vac
Load Regulation± 0.5%
PARD< 200 mVpp @ 0°C to +70°C < 600 mVpp @ 30°C to 0°C
Start-up Time500 ms typ. @ 115 Vac & 230 Vac (24 V) 800 ms typ. @ 115 Vac & 230 Vac (48 V)
Hold-up Time25 ms typ. @ 115 Vac & 230 Vac (100% load)
Dynamic Response (Overshoot & Undershoot O/P Voltage)± 10% @ 115 Vac & 230 Vac input, 10-100% load (Slew Rate: 2.5 A/μS, 50% duty cycle @ 5 Hz & 10 kHz)
Start-up with Capacitive Loads3,000 µF Max
Rise Time30 ms typ. @ 115 Vac & 230Vac
Nominal Input Voltage100-240 Vac
Input Voltage Range90-264 Vac
Nominal Input Frequency50-60 Hz
Input Frequency Range47-63Hz
Input Current4.7 A typ. @ 115 Vac, 2.4 A typ. @ 230 Vac
Efficiency at 100% load93.5% typ. @ 230 Vac
Inrush Current40 A typ. @ 230 Vac
Leakage Current< 1.5 mA @ 240 Vac
Case Chassis / CoverAluminum
IndicatorGreen LED DC OK
Cooling SystemConvection
Input Terminal3 Pins (Rated 600 V / 30 A)
Output Terminal4 Pins (Rated 600 V / 30 A)
Noise Sound Pressure Level (SPL)<25 dBA
Mounting RailStandard TS35 DIN Rail in accordance with EN 60715
Unit Weight0.87 kg (1.92 lb)
Vibration (Operating)IEC 60068-2-6, Sine Wave: 10 Hz to 500 Hz; 3 G peak; 60 min per axis for all X, Y, Z directions
Shock Test (Operating)IEC 60068-2-27, Half Sine Wave: 10 G for duration of 11 ms; 1 time in X axis
Operating Temperature-30°C to +70°C (-40°C Cold Start)
Storage Temperature-40°C to +85°C
Power De-ratingTemperature: > 40°C de-rate power by 1.67 % / °C @ 115 Vac > 50°C de-rate power by 2.5 % / °C @ 230 Vac Input Voltage < 100Vac de-rate power by 1% / Vac
Operating Humidity20 to 90% RH (Non-Condensing)
Shock Test (Non-Operating)IEC 60068-2-27, Half Sine Wave: 50 G for duration of 11 ms; 3 times per direction, 9 times in total
Vibration (Non-Operating)IEC 60068-2-6, Random: 5 Hz to 500 Hz (2.09 G); 20 min per axis for all X, Y, Z direction
Operating Altitude0 to 5,000 Meters (16,400 ft.)
Pollution Degree2
Over Voltage CategoryII (Compliance to EN 62477-1 OVC III with 2000 meters altitude)
Power Factor at 100% load> 0.96 @ 115 Vac & > 0.93 @ 230 Vac
Input Power (Standby Mode)0.75 W max @ 115 Vac & 230 Vac
WireInput: AWG 14-12 Output: AWG 14-12
Talk to Our Engineer for Delta 480W 48V DIN Rail Power Supply DRL-48V480W1ENA with exclusive offers. Core System Specifications of DRL-48V480W1ENA are 10A Output Current, 48V Output Voltage, 480W Output Power at competitive prices. It operates with a nominal input voltage of 100-240 Vac and supports an input voltage range of 90-264 Vac. The power supply covers a nominal input frequency of 50-60 Hz, with a broader input frequency range of 47-63Hz. With an input current of 4.7 A typ. @ 115 Vac, 2.4 A typ. @ 230 Vac, it ensures efficient performance. The unit features a Green LED DC OK indicator, aiding in quick status checks. Both input and output terminals have 3 Pins (Rated 600 V / 30 A) and 4 Pins (Rated 600 V / 30 A) for secure connections. Designed for extreme environments, it Operating Temperature from -30°C to +70°C (-40°C Cold Start) and has a storage temperature of -40°C to +85°C. Don't Miss Out on a Quote for your requirement of 480W 48V DIN Rail Power Supply. Count on us for more economical pricing and more reliable support than other Dealers & Distributors.