DRL-48V120W1ENA - Delta 120W 48V DIN Rail Power Supply

Technical Specifications of Delta DRL-48V120W1ENA 120W 48V DIN Rail Power Supply

BrandDelta
Product TypeSMPS
ProductDRL-48V120W1ENA

Delta 120W 48V DIN Rail Power Supply DRL-48V120W1ENA Technical Specifications:

SpecificationValue
Output Current2.5A
Output Voltage48V
Output Voltage Adjustment Range43.2-52.8Vdc
Output Power120W
Output Voltage Range43.2-52.8Vdc
Line Regulation± 0.5% @ 115Vac & 230Vac
Load Regulation± 0.5%
PARD< 200mVpp @ 0°C to +70°C < 600mVpp @ -30°C to 0°C
Start-up Time500ms typ. @ 115Vac & 230Vac
Hold-up Time10ms typ. @ 115Vac (100% load) 16ms typ. @ 230Vac (100% load)
Dynamic Response (Overshoot & Undershoot O/P Voltage)± 10% @ 115Vac & 230Vac input, 10-100% load (Slew Rate: 2.5A/μS, 50% duty cycle @ 5Hz & 10KHz)
Start-up with Capacitive Loads3,000µF Max
Rise Time30ms typ. @ 115Vac & 230Vac
Nominal Input Voltage100-240Vac
Input Voltage Range90-264Vac
Nominal Input Frequency50-60Hz
Input Frequency Range47-63Hz
Input Current2.1A typ. @ 115Vac, 1.3A typ. @ 230Vac
Efficiency at 100% load89.5% typ.@ 230Vac
Inrush Current35A typ. @ 230Vac
Leakage Current< 0.5mA @ 240Vac
Case Chassis / CoverAluminum / SGCC
IndicatorGreen LED (DC OK)
Cooling SystemConvection
Input Terminal3 Pins (Rated 300V/30A)
Output Terminal4 Pins (Rated 300V/20A)
Noise Sound Pressure Level (SPL)< 25dBA
Mounting RailStandard TS35 DIN Rail in accordance with EN 60715
Unit Weight0.45 kg (0.99 lb)
Vibration (Operating)IEC 60068-2-6, Sine Wave: 10Hz to 500Hz @ 19.6 m/s² (2G peak); 10 min per cycle, 60 min for X direction
Shock Test (Operating)IEC 60068-2-27, Half Sine Wave: 10G for duration of 11ms; 1 time in X axis
Operating Temperature-30°C to +70°C (-40°C Cold Start)
Storage Temperature-40°C to +85°C
Power De-rating> 40°C de-rate power by 1.67 % / °C @115Vac > 50°C de-rate power by 2.5 % / °C @230Vac
Operating Humidity20 to 90% RH (Non-Condensing)
Shock Test (Non-Operating)IEC 60068-2-27, Half Sine Wave: 50G for duration of 11ms; 3 times per direction, 9 times in total
Vibration (Non-Operating)IEC 60068-2-6, Random: 5Hz to 500Hz (2.09G); 20 min per axis for all X, Y, Z direction
Operating Altitude0 to 5,000 Meters (16,400 ft.)
Pollution Degree2
Over Voltage CategoryII (Compliance to EN 62477-1 OVC III with 2000 meters altitude)
Ask for the Pricing of Delta 120W 48V DIN Rail Power Supply DRL-48V120W1ENA at unbeatable prices. Detailed Specifications of DRL-48V120W1ENA features 2.5A Output Current, 48V Output Voltage, 120W Output Power at competitive prices. It operates with a nominal input voltage of 100-240Vac and supports an input voltage range of 90-264Vac. The power supply covers a nominal input frequency of 50-60Hz, with a broader input frequency range of 47-63Hz. With an input current of 2.1A typ. @ 115Vac, 1.3A typ. @ 230Vac, it ensures efficient performance. The unit features a Green LED (DC OK) indicator, aiding in quick status checks. Both input and output terminals have 3 Pins (Rated 300V/30A) and 4 Pins (Rated 300V/20A) for secure connections. Designed for extreme environments, it Operating Temperature from -30°C to +70°C (-40°C Cold Start) and has a storage temperature of -40°C to +85°C. Now's the Time to Secure a Quote for your requirement of 120W 48V DIN Rail Power Supply. We're committed to offering more favorable pricing and more responsive support than other Traders.