DRL-48V120W1ENA - Delta 120W 48V DIN Rail Power Supply
Technical Specifications of Delta DRL-48V120W1ENA 120W 48V DIN Rail Power Supply

| Brand | Delta |
| Product Type | SMPS |
| Product | DRL-48V120W1ENA |
Delta 120W 48V DIN Rail Power Supply DRL-48V120W1ENA Technical Specifications:
| Specification | Value |
|---|---|
| Output Current | 2.5A |
| Output Voltage | 48V |
| Output Voltage Adjustment Range | 43.2-52.8Vdc |
| Output Power | 120W |
| Output Voltage Range | 43.2-52.8Vdc |
| Line Regulation | ± 0.5% @ 115Vac & 230Vac |
| Load Regulation | ± 0.5% |
| PARD | < 200mVpp @ 0°C to +70°C < 600mVpp @ -30°C to 0°C |
| Start-up Time | 500ms typ. @ 115Vac & 230Vac |
| Hold-up Time | 10ms typ. @ 115Vac (100% load) 16ms typ. @ 230Vac (100% load) |
| Dynamic Response (Overshoot & Undershoot O/P Voltage) | ± 10% @ 115Vac & 230Vac input, 10-100% load (Slew Rate: 2.5A/μS, 50% duty cycle @ 5Hz & 10KHz) |
| Start-up with Capacitive Loads | 3,000µF Max |
| Rise Time | 30ms typ. @ 115Vac & 230Vac |
| Nominal Input Voltage | 100-240Vac |
| Input Voltage Range | 90-264Vac |
| Nominal Input Frequency | 50-60Hz |
| Input Frequency Range | 47-63Hz |
| Input Current | 2.1A typ. @ 115Vac, 1.3A typ. @ 230Vac |
| Efficiency at 100% load | 89.5% typ.@ 230Vac |
| Inrush Current | 35A typ. @ 230Vac |
| Leakage Current | < 0.5mA @ 240Vac |
| Case Chassis / Cover | Aluminum / SGCC |
| Indicator | Green LED (DC OK) |
| Cooling System | Convection |
| Input Terminal | 3 Pins (Rated 300V/30A) |
| Output Terminal | 4 Pins (Rated 300V/20A) |
| Noise Sound Pressure Level (SPL) | < 25dBA |
| Mounting Rail | Standard TS35 DIN Rail in accordance with EN 60715 |
| Unit Weight | 0.45 kg (0.99 lb) |
| Vibration (Operating) | IEC 60068-2-6, Sine Wave: 10Hz to 500Hz @ 19.6 m/s² (2G peak); 10 min per cycle, 60 min for X direction |
| Shock Test (Operating) | IEC 60068-2-27, Half Sine Wave: 10G for duration of 11ms; 1 time in X axis |
| Operating Temperature | -30°C to +70°C (-40°C Cold Start) |
| Storage Temperature | -40°C to +85°C |
| Power De-rating | > 40°C de-rate power by 1.67 % / °C @115Vac > 50°C de-rate power by 2.5 % / °C @230Vac |
| Operating Humidity | 20 to 90% RH (Non-Condensing) |
| Shock Test (Non-Operating) | IEC 60068-2-27, Half Sine Wave: 50G for duration of 11ms; 3 times per direction, 9 times in total |
| Vibration (Non-Operating) | IEC 60068-2-6, Random: 5Hz to 500Hz (2.09G); 20 min per axis for all X, Y, Z direction |
| Operating Altitude | 0 to 5,000 Meters (16,400 ft.) |
| Pollution Degree | 2 |
| Over Voltage Category | II (Compliance to EN 62477-1 OVC III with 2000 meters altitude) |
Ask for the Pricing of Delta 120W 48V DIN Rail Power Supply DRL-48V120W1ENA at unbeatable prices. Detailed Specifications of DRL-48V120W1ENA features 2.5A Output Current, 48V Output Voltage, 120W Output Power at competitive prices. It operates with a nominal input voltage of 100-240Vac and supports an input voltage range of 90-264Vac. The power supply covers a nominal input frequency of 50-60Hz, with a broader input frequency range of 47-63Hz. With an input current of 2.1A typ. @ 115Vac, 1.3A typ. @ 230Vac, it ensures efficient performance. The unit features a Green LED (DC OK) indicator, aiding in quick status checks. Both input and output terminals have 3 Pins (Rated 300V/30A) and 4 Pins (Rated 300V/20A) for secure connections. Designed for extreme environments, it Operating Temperature from -30°C to +70°C (-40°C Cold Start) and has a storage temperature of -40°C to +85°C. Now's the Time to Secure a Quote for your requirement of 120W 48V DIN Rail Power Supply. We're committed to offering more favorable pricing and more responsive support than other Traders.