Technical Specifications of Delta DRL-24V75W1AZR 75W 24V DIN Rail Power Supply

| Brand | Delta |
| Product Type | SMPS |
| Product | DRL-24V75W1AZR |
Delta 75W 24V DIN Rail Power Supply DRL-24V75W1AZR Technical Specifications:
| Specification | Value |
|---|---|
| Output Current | 3.125A |
| Output Voltage | 24V |
| Output Power | 75W |
| Output Voltage Adjustment Range | 21.6-26Vdc |
| Line Regulation | < 0.5% (@ 85-264Vac, 100% load) |
| Load Regulation | < 1% (0-100% load) |
| PARD | < 120mVpp @ > -10°C to +70°C < 360mVpp @ ≤ -10°C to -30°C |
| Start-up Time | 1200ms typ. @ 115Vac (100% load) 1000ms typ. @ 230Vac (100% load) |
| Hold-up Time | 16ms typ. @ 115Vac (100% load) 60ms typ. @ 230Vac (100% load) |
| Dynamic Response (Overshoot & Undershoot O/P Voltage) | ± 10% @ 115Vac & 230Vac input, 0-50%, 50-100% load (Slew Rate: 2.5A/μS, 50% duty cycle @ 100Hz & 1KHz) |
| Start-up with Capacitive Loads | 5,000µF Max |
| Rise Time | 30ms typ. @ nominal input (100% load) |
| Nominal Input Voltage | 100-240Vac |
| Input Voltage Range | 85-264Vac |
| Nominal Input Frequency | 50-60Hz |
| Input Frequency Range | 47-63Hz |
| DC Input Voltage Range | 120-375 Vdc |
| Input Current | 1.4A typ. @ 115Vac, 0.9A typ. @ 230Vac |
| Efficiency at 100% load | 89% typ. @ 230Vac |
| Inrush Current | 50A typ. @ 230Vac |
| Leakage Current | < 1mA @ 240Vac |
| Case Chassis / Cover | Plastic |
| Indicator | Green LED (DC OK) |
| Cooling System | Convection |
| Unit Weight | 0.22 kg (0.49 lb) |
| Vibration (Operating) | IEC 60068-2-6, Sine Wave: 10Hz to 500Hz @ 19.6m/s² (2G peak); displacement of 0.35mm; 10 min per cycle, 60 min for X direction |
| Shock Test (Operating) | IEC 60068-2-27, Half Sine Wave: 10G for duration of 11ms; 1 time in X axis |
| Operating Temperature | -20°C to +70°C (-30°C Cold Start) |
| Storage Temperature | -40°C to +85°C |
| Power De-rating | -10°C to -20°C de-rate power by 1% / °C > 40°C de-rate power by 1.67% / °C @ 115Vac > 50°C de-rate power by 2.5% / °C @ 230Vac Input Voltage: < 100Vac de-rate power by 1.33% / Vac |
| Operating Humidity | 5 to 95% RH (Non-Condensing) |
| Shock Test (Non-Operating) | IEC 60068-2-27, Half Sine Wave: 50G for duration of 11ms; 3 times per direction, 9 times in total |
| Vibration (Non-Operating) | IEC 60068-2-6, Random: 5Hz to 500Hz; 2.09Grms; 20 min per axis for all X, Y, Z directions |
| Operating Altitude | 0 to 5,000 Meters (16,400 ft.) |
| Pollution Degree | 2 |
| Over Voltage Category | II |
Get A Quote for Delta 75W 24V DIN Rail Power Supply DRL-24V75W1AZR at the best price. Here are the brief Technical Specifications of DRL-24V75W1AZR are 3.125A Output Current, 24V Output Voltage, 75W Output Power at competitive prices. It operates with a nominal input voltage of 100-240Vac and supports an input voltage range of 85-264Vac. The power supply covers a nominal input frequency of 50-60Hz, with a broader input frequency range of 47-63Hz. With an input current of 1.4A typ. @ 115Vac, 0.9A typ. @ 230Vac, it ensures efficient performance. The unit features a Green LED (DC OK) indicator, aiding in quick status checks for secure connections. Designed for extreme environments, it Operating Temperature from -20°C to +70°C (-30°C Cold Start) and has a storage temperature of -40°C to +85°C. It's Time to get a Quote for your requirement of 75W 24V DIN Rail Power Supply. We guarantee unmatched pricing and unparalleled support compared to other Distributors.