Technical Specifications of Delta DRL-12V120W1EN 10A 12V DIN Rail Power Supply

BrandDelta
Product TypeSMPS
ProductDRL-12V120W1EN

Delta 10A 12V DIN Rail Power Supply DRL-12V120W1EN Technical Specifications:

SpecificationValue
Output Current10A
Output Voltage12V
Output Voltage Adjustment Range10.8-13.2Vdc
Output Power120W
Output Voltage Range10.8-13.2Vdc
Line RegulationΒ± 0.5% @ 115Vac & 230Vac
Load RegulationΒ± 1.0%
PARD< 120mVpp @ 0Β°C to +70Β°C < 360mVpp @ -30Β°C to 0Β°C
Start-up Time500ms typ. @ 115Vac & 230Vac
Hold-up Time10ms typ. @ 115Vac (100% load) 16ms typ. @ 230Vac (100% load)
Dynamic Response (Overshoot & Undershoot O/P Voltage)Β± 10% @ 115Vac & 230Vac input, 10-100% load (Slew Rate: 2.5A/ΞΌS, 50% duty cycle @ 5Hz & 10KHz)
Start-up with Capacitive Loads8,000Β΅F Max
Rise Time30ms typ. @ 115Vac & 230Vac
Nominal Input Voltage100-240Vac
Input Voltage Range90-264Vac
Nominal Input Frequency50-60Hz
Input Frequency Range47-63Hz
Input Current2.1A typ. @ 115Vac, 1.3A typ. @ 230Vac
Efficiency at 100% load86% typ.@ 230Vac
Inrush Current35A typ. @ 230Vac
Leakage Current< 0.5mA @ 240Vac
Case Chassis / CoverAluminum / SGCC
IndicatorGreen LED (DC OK)
Cooling SystemConvection
Input Terminal3 Pins (Rated 300V/30A)
Output Terminal4 Pins (Rated 300V/20A)
Noise Sound Pressure Level (SPL)< 25dBA
Mounting RailStandard TS35 DIN Rail in accordance with EN 60715
Unit Weight0.45 kg (0.99 lb)
Vibration (Operating)IEC 60068-2-6, Sine Wave: 10Hz to 500Hz @ 19.6 m/sΒ² (2G peak); 10 min per cycle, 60 min for X direction
Shock Test (Operating)IEC 60068-2-27, Half Sine Wave: 10G for duration of 11ms; 1 time in X axis
Operating Temperature-30Β°C to +70Β°C (-40Β°C Cold Start)
Storage Temperature-40Β°C to +85Β°C
Power De-rating> 40Β°C de-rate power by 1.67 % / Β°C @115Vac > 50Β°C de-rate power by 2.5 % / Β°C @230Vac
Operating Humidity20 to 90% RH (Non-Condensing)
Shock Test (Non-Operating)IEC 60068-2-27, Half Sine Wave: 50G for duration of 11ms; 3 times per direction, 9 times in total
Vibration (Non-Operating)IEC 60068-2-6, Random: 5Hz to 500Hz (2.09G); 20 min per axis for all X, Y, Z direction
Operating Altitude0 to 5,000 Meters (16,400 ft.)
Pollution Degree2
Over Voltage CategoryII (Compliance to EN 62477-1 OVC III with 2000 meters altitude)
IndMALL Automation Dealing offers Delta 10A 12V DIN Rail Power Supply DRL-12V120W1EN at unbeatable prices. The Main Technical Parameters of DRL-12V120W1EN are 10A Output Current, 12V Output Voltage, 120W Output Power at competitive prices. It operates with a nominal input voltage of 100-240Vac and supports an input voltage range of 90-264Vac. The power supply covers a nominal input frequency of 50-60Hz, with a broader input frequency range of 47-63Hz. With an input current of 2.1A typ. @ 115Vac, 1.3A typ. @ 230Vac, it ensures efficient performance. The unit features a Green LED (DC OK) indicator, aiding in quick status checks. Both input and output terminals have 3 Pins (Rated 300V/30A) and 4 Pins (Rated 300V/20A) for secure connections. Designed for extreme environments, it Operating Temperature from -30Β°C to +70Β°C (-40Β°C Cold Start) and has a storage temperature of -40Β°C to +85Β°C. Take the First Step with a Quote for your requirement of 10A 12V DIN Rail Power Supply. Choose us for unparalleled pricing and support over other Dealers & Distributors.

Disclaimer: IndMALL serves solely as a platform connecting buyers and vendors. It does not participate in pricing, payment, or delivery of goods.
Buyers are advised to verify all details and deal directly with vendors before finalizing any transaction.