Technical Specifications of Beckhoff EtherCAT Terminal Analog Input EL3214:

BrandBeckhoff
Product TypeEtherCAT Terminal Analog Input
ProductEL3214

EL3214 Beckhoff EtherCAT Terminal Analog Input Technical Specifications

SpecificationValue
Number of inputs4
Ground reference (input)single-ended
Input filter limit frequencytyp. 1 kHz
Measurement error/uncertainty 2<±0.5°C for Pt sensors, 4 x 3-wire connection
Housing - Design formHD (High Density) housing with signal LEDs
Housing - Materialpolycarbonate
Housing - Dimensions (W x H x D)12Â mm x 100Â mm x 68 mm
Housing - Installationon 35 mm DIN rail, conforming to EN 60715 with lock
Housing - Side by side mounting by means ofdouble slot and key connection
Housing - Markinglabeling of the BZxxxx series
Housing - Wiringsolid conductors (s): direct plug-in technique; fine-stranded conductors (st) and ferrule (f): spring actuation by screwdriver
Housing - Connection cross-sections*: 0.08..2.5 mm²,st*: 0.08...2.5 mm²,f*: 0.14..1.5 mm²
Housing - Connection cross-section AWGs*: AWG28..14,st*: AWG28..14,f*: AWG26...16
Housing - Stripping length8…9 mm
Housing - Current load power contactsImax: 10 A
Power supplyvia the E-bus
Conversion timeapprox. 170 ms default setting
Electrical isolation500 V (E-bus/signal voltage)
Current consumption E-bustyp. 140 mA
Special featuresintegrated digital filter, limit value monitoring, variable connection technology
Weightapprox. 60 g
Operating temperature-25…+60°C
Storage temperature-40…+85°C
Relative humidity95%, no condensation
Vibration/shock resistanceconforms to EN 60068-2-6/EN 60068-2-27
EMC immunity/emissionconforms to EN 61000-6-2/EN 61000-6-4
Protect. rating/installation pos.IP20/variable
Approvals/markingsCE, UL, DNVÂ GL
Sensor typesPt100, Pt200, Pt500, Pt1000, Ni100, Ni120, Ni1000, resistance measurement (e.g. potentiometer, 10 Ω…1/4 kΩ), KTY sensors (types see documentation)
Connection method2- or 3-wire (default: 3-wire)
Measuring current< 0.5 mA (load-dependent)
Temperature range-200…+850°C (Pt sensors); -60…+250°C (Ni sensors)
Measuring range-200…+850°C (Pt sensors); -60…+250°C (Ni sensors)