+91 79955 44066
IndMALL: B2B Marketplace - We Connect Buyers & Sellers for Industrial Products

EL3204-0162 - Beckhoff EtherCAT Terminal Analog Input

Technical Specifications of Beckhoff EtherCAT Terminal Analog Input EL3204-0162:

BrandBeckhoff
Product TypeEtherCAT Terminal Analog Input
ProductEL3204-0162

EL3204-0162 Beckhoff EtherCAT Terminal Analog Input Technical Specifications

SpecificationValue
Number of inputs2 x Pt100, 2 x -10…+10 V
Measurement error/uncertainty> 130 kΩ
Input filter limit frequencytyp. 1 kHz
Dielectric strengthmax. 30 V
Measurement error/uncertainty 2RTD measurement: < ±0.5°C for Pt sensors, voltage measurement: < ±0.3% (relative to full scale value)
Housing - Design formcompact terminal housing with signal LEDs
Housing - Materialpolycarbonate
Housing - Dimensions (W x H x D)12Â mm x 100Â mm x 68 mm
Housing - Installationon 35 mm DIN rail, conforming to EN 60715 with lock
Housing - Side by side mounting by means ofdouble slot and key connection
Housing - Markinglabeling of the BZxxxx series
Housing - Wiringsolid conductor (s), flexible conductor (st) and ferrule (f): spring actuation by screwdriver
Housing - Connection cross-sections*: 0.08..2.5 mm²,st*: 0.08...2.5 mm²,f*: 0.14..1.5 mm²
Housing - Connection cross-section AWGs*: AWG28..14,st*: AWG28..14,f*: AWG26...16
Housing - Stripping length8…9 mm
Housing - Current load power contactsImax: 10 A
Power supplyvia the E-bus
Conversion timeRTD measurement: 85 ms default setting, 2…800 ms configurable, voltage measurement: 0.625 ms default setting, configurable, multiplex
Electrical isolation500 V (E-bus/signal voltage)
Current consumption E-bustyp. 130 mA
Special featuresintegrated digital filter, limit value monitoring
Weightapprox. 60 g
Operating temperature0...55°C
Storage temperature-25....+85°C
Relative humidity95%, no condensation
Vibration/shock resistanceconforms to EN 60068-2-6/EN 60068-2-27
EMC immunity/emissionconforms to EN 61000-6-2/EN 61000-6-4
Protect. rating/installation pos.IP20/variable
Approvals/markingsCE, UL
Pluggable wiringfor all ESxxxx terminals
Sensor typesPt100, Pt200, Pt500, Pt1000, Ni100, Ni120, Ni1000, resistance measurement (e.g. potentiometer, 10 Ω…1/4 kΩ), KTY sensors (types see documentation)
Connection method2-wire
Measuring current< 0.5 mA (load-dependent)
Temperature range-200…+850°C (Pt sensors); -60…+250°C (Ni sensors)

Disclaimer: IndMALL serves solely as a platform connecting buyers and vendors. It does not participate in pricing, payment, or delivery of goods.
Buyers are advised to verify all details and deal directly with vendors before finalizing any transaction.