+91 79955 44066
IndMALL: B2B Marketplace - We Connect Buyers & Sellers for Industrial Products

Baumer FlexTop 2212 Temperature Measurement

The Baumer FlexTop 2212 Temperature Measurement offers a 0 … 60 s, 4 … 20 mA , 2-wire, 20 … 4 mA , 2-wire, and power supply. Manufactured by Baumer under the Baumer Temperature Measurement category, this model belongs to the VS Series.

BrandBaumer
Product TypeTemperature Measurement
Model NumberFlexTop 2212

Baumer FlexTop 2212 Temperature Measurement – Technical Specifications

SpecificationValue
Degree of protection (EN 60529)IP 55
Humidity< 98 % RH , condensing
Damping0 … 60 s
Output signal4 … 20 mA , 2-wire, 20 … 4 mA , 2-wire
Accuracy< 0.025 % FSR
Temperature drift± 0.01 %/K , max.
Load resistanceRs ≤ (V DC - 7 V)/0.023 A
Resolution14 bit
Up/Down scaling limits23 mA / 3.5 mA
Ripple immunity< 1 % FSR (1 Vrms, 50Hz...1kHz)
Effect of variations in supply voltage0.001 %/V
EMCEN 61326-1, DNV GL - Class A, EN 50121-3-2:2016
NamurNE21
Explosion protectionATEX II 1 G Ex ia IIC T6...T4, ATEX II 3 G Ex ec IIC T6...T5 Gc, IECEx Ex ia IIC T6...T4, IECEx Ex ec IIC T6...T5 Gc
CharacteristicLinear or customised with max. 30 points
Step response time, T90< 450 ms
Ask for the Pricing of Baumer Temperature Measurement FlexTop 2212 at unbeatable prices. Detailed Specifications of FlexTop 2212, feature transmitter is rated IP 55 for protection and operates efficiently in humidity levels below < 98 % RH , condensing. It meets 14 bit Resolution. Built to withstand industrial conditions, it endures Up/Down scaling limits of 23 mA / 3.5 mA, with a Ripple immunity < 1 % FSR (1 Vrms, 50Hz...1kHz) standards. The damping is 0 … 60 s, providing precise control. The output signal is an 4 … 20 mA , 2-wire, 20 … 4 mA , 2-wire configuration, ensuring stable and accurate transmission. With an accuracy of < 0.025 % FSR and temperature drift of ± 0.01 %/K , max., it maintains exceptional precision. The load resistance follows Rs ≤ (V DC - 7 V)/0.023 A for optimal operation. Now's the Time to Secure a Quote for your requirement of Temperature Measurement. We're committed to offering more favorable pricing and more responsive support than other Traders.

Disclaimer: IndMALL serves solely as a platform connecting buyers and vendors. It does not participate in pricing, payment, or delivery of goods.
Buyers are advised to verify all details and deal directly with vendors before finalizing any transaction.