During technical comparisons, KN-2001W appears alongside Autonics Proximity Sensor, Autonics Digital Counter and Autonics Kn 1000B so engineers assess signal types, ingress protection, and ambient tolerances accurately.
Autonics KN-2001W Indicator
The Autonics KN-2001W Indicator offers JPt100Ω, DPt100Ω, DPt50Ω, Cu50Ω, Cu100Ω (5 types) input type, K, J, E, T, R, B, S, N, C (W5), L, U, PLII (12 types), 24VDC power supply. Manufactured by Autonics under the Autonics Indicators category, this model belongs to the Autonics KN Series.

| Brand | Autonics |
| Product Type | Indicators |
| Model Number | KN-2001W |
Autonics KN-2001W Indicator – Technical Specifications
| Specification | Value |
|---|---|
| Power supply_DC power | 24VDC |
| Input type_RTD | JPt100Ω, DPt100Ω, DPt50Ω, Cu50Ω, Cu100Ω (5 types) |
| Input type_TC | K, J, E, T, R, B, S, N, C (W5), L, U, PLII (12 types) |
| Input type_Analog | · Voltage: ±1.0000V, ±50.00mV, ±200.0mV, 1.000-10.000V (4 types)· Current: 4.00-20.00mA, 0.00-20.00mA (2 types) |
| Display accuracy | ±0.2% F.S. ±1-digit (25℃±5℃)±0.3% F.S. ±1-digit ( 10℃ to 20℃, 30℃ to 50℃)In case of thermocouple and below -100˚C input, [ ±0.4%F.S. ] ±1-digit※TC-T, TC-U is min. ±2.0℃ |
| Environment_Ambient temperature | -10 to 50℃, storage: -20 to 60℃ |
| Environment_Ambient humidity | 35 to 85% RH, storage: 35 to 85% RH |
| Weight | Approx. 332g (approx. 200g) |
Obtain a Quote for Autonics 1-channel Digital Indicators KN-2001W at economical prices. Specifications Overview for KN-2001W reveals Supporting RTD inputs like JPt100Ω, DPt100Ω, DPt50Ω, Cu50Ω, Cu100Ω (5 types), and thermocouple (TC) inputs including K, J, E, T, R, B, S, N, C (W5), L, U, PLII (12 types), these controllers ensure versatile temperature measurement. Analog inputs range from · Voltage: ±1.0000V, ±50.00mV, ±200.0mV, 1.000-10.000V (4 types)· Current: 4.00-20.00mA, 0.00-20.00mA (2 types). Display accuracy is ±0.2% F.S. ±1-digit (25℃±5℃)±0.3% F.S. ±1-digit ( 10℃ to 20℃, 30℃ to 50℃)In case of thermocouple and below -100˚C input, [ ±0.4%F.S. ] ±1-digit※TC-T, TC-U is min. ±2.0℃ has an accuracy. Operating conditions include an ambient temperature range of -10 to 50℃, storage: -20 to 60℃ and humidity between 35 to 85% RH, storage: 35 to 85% RH. With a weight of Approx. 332g (approx. 200g), these controllers ensure reliable performance. Take the First Step with a Quote for your requirement of 1-channel Digital Indicators. Our commitment to better pricing and exceptional support sets us apart from other Competitors.