| Directing opening force | Min. 80N |
| Directing opening distance | Min. 10mm |
| Locking pullout strength | Min. 1,300N |
| Operating speed | 0.05 to 1m/s |
| Operating frequency | Max. 20/min |
| Life cycle_Mechanical | Min. 1,000,000 operations (20/min) |
| Indicator | Solenoid status or contact status (orange, depending on connection) |
| Vibration_Malfunction | 0.35mm single amplitude at frequency of 10 to 55Hzin each X,Y,Z direction for 10 min |
| Shock | 1,000m/s² (approx. 100G) in each X, Y, Z direction for 3 times |
| Shock_Malfunction | 80m/s² (approx. 8G) in each X, Y, Z direction for 3 times |
| Environment_Ambient temperature | -10 to 55℃, storage: -25 to 65℃ |
| Environment_Ambient humidity | 35 to 85% RH, storage: 35 to 85% RH |
| Protection structure | IP67(IEC standerd, except head) |
| Material | Head: zinc or PA, case: PA |
| Rated load voltage & current | Resistive load: 6 A/250 VAC~, 0.6 A/250 VDC@(=)Inductive load (IEC): AC-15 3 A/240 VAC~, DC-13 0.27 A/250 VDC@(=)Inductive load (UL): A300, Q300 |
| Dielectric strength_Between the terminals of same polarity | 2.5kV |
| Dielectric strength_Between the terminals of different polarity | 4 kV |
| Dielectric strength_Between each terminal and non-live part | 6 kV |
| Insulation resistance | 100MΩ or more (500VDC megger basis) |
| Contact resistance | ≤ 100 mΩ |
| Life cycle_Electrical | ≥ 100,000 operations (250 VAC~/6 A) |
| Conditional short circuit current | 100A |
| Rated voltage | 24 VDC@(=), class 2 |
| Current consumption | Supplying power: 0.26ANormal: max. 0.2A (approx. 3 seconds after supplying power) |
| Insulation class | Class E |
| Weight | ≈ 400 g (≈ 490 g) |