Omron G3PW-A245EC-C-FLK Solid-state Relay
Omron G3PW-A245EC-C-FLK is a single-phase power controller with a 45 A rated operational current and constant-current control. Its rated operational voltage is 100 to 240 V, while the specified operating range is 85 to 264 V. The model accepts a 1 to 5 V control input and uses push-in and screw terminals. Heater burnout detection and Serial RS-485 communication are listed, along with a 1600 A²s permissible I²t value and an 11 kW heater load capacity. Operating temperature is specified from -15°C to 55°C. The G3PW-A245EC-C-FLK controller is part of the power switching and SSR range from Omron control equipment.

| Brand | Omron |
| Product | Solid State Relay |
| Model Number | G3PW-A245EC-C-FLK |
Omron G3PW-A245EC-C-FLK Solid-state Relay - Technical Specifications
| Specification | Value |
|---|---|
| Application | Power control |
| Number Of Phases | 1 |
| Terminal Type | Push-in, Screw |
| Features | Constant current |
| Rated Operational Voltage Ac | 100-240 V |
| Operating Voltage Range Ac | 85-264 V |
| Rated Operation Current Ie At Ac 1 | 45 A |
| Permissible I T Value | 1600 A²s |
| Applicable Heater Capacity Ac1 Resistive Load | 11 kW |
| Supply Voltage Dc | 1-5 V |
| Maximum Operating Temperature | 55 °C |
| Minimum Operating Temperature | -15 °C |
| Functions | Heater burnout detection |
| Communication Port S | Serial RS-485 |
The Omron G3PW-A245EC-C-FLK Solid State Relay is a single-phase power controller rated for 45 A and specified with constant-current control. Its rated operational voltage is 100 to 240 V and its operating range extends from 85 to 264 V. A 1 to 5 V control input is listed, along with push-in and screw terminals. The supplied row includes heater burnout detection and Serial RS-485 communication. Permissible I²t is specified as 1600 A²s, while the applicable heater load capacity is 11 kW. The operating-temperature range is -15°C to 55°C. These structured values define the higher-current G3PW-A245EC-C-FLK configuration without relying on the promotional claims present in the source prose.
Compared with the 20 A EC models in the same family, this row increases rated operational current to 45 A, permissible I²t to 1600 A²s, and heater capacity to 11 kW while retaining the 100 to 240 V rated voltage, 85 to 264 V operating range, 1 to 5 V control input, constant-current control, heater burnout detection, and Serial RS-485 fields. Its listed terminal arrangement remains push-in and screw. For a higher-current G3PW entry that keeps the 1600 A²s permissible I²t value but raises rated operational current and heater capacity, compare G3PW-A260EC-C-FLK.