+91 79955 44066
IndMALL: B2B Marketplace - We Connect Buyers & Sellers for Industrial Products

Omron H5CX-BWSD-N Timer

The Omron H5CX-BWSD-N Timer is a compact industrial timing unit designed to operate within 85 to 110% of rated supply voltage.It features 4 time ranges along with a No-voltage (NPN)/Voltage (PNP) input (selectable) input method. Its 7-segment negative transmissive LCD 6 digit provides clear visibility, while static immunity of 8 kV mulfunction and 15 kV destruction ensures reliable operation. Manufactured by Omron, listed under Omron Timers, this model belongs to the H5CX Series and supports Flush mounting with Screw terminal connections in a Black (Munsell N1.5) case.

BrandOmron
ProductTimers
Model NumberH5CX-BWSD-N

Omron H5CX-BWSD-N Timer - Technical Specifications

SpecificationValue
Rated supply voltage12 to 24 VDC (Ripple 20% max.)
Operating voltage range85 to 110% of rated supply voltage
Connection methodScrew terminal
Mounting methodFlush mounting
Power consumptionApprox. 2.3 W
Time ranges (Number of ranges)4
Time ranges0.01 to 9999.99 s 0.1 to 99999.9 min 0.1 to 99999.9 h 1 s to 99 h 59 min 59 s
Input methodNo-voltage (NPN)/Voltage (PNP) input (selectable)
Output modesA: Signal ON delay F-1: Cumulative
Reset systemPower reset (A mode)/External reset/Manual reset
Timer modeElapsed time (UP)
Display method7-segment negative transmissive LCD 6 digit
Character heightPresent value: 12 mm (Red, green or orange programmable) Set value: 6 mm (green)
Ambient temperature range-10 to 55 ℃ (with no freezing or condensation) When mount timer side by side: -10 to 50 ℃ (with no freezing or condensation)
Ambient humidity (Operating)25 to 85%
Accuracy of operating timePower-ON start: Β±0.01% Β±0.05 s max. (The values are based on the set value.) Signal start: Β±0.005% Β±3 ms max. (The values are based on the set value. The value is applied for a minimum pulse width of 1 ms.)
Setting errorPower-ON start: Β±0.01% Β±0.05 s max. (The values are based on the set value.) Signal start: Β±0.005% Β±3 ms max. (The values are based on the set value. The value is applied for a minimum pulse width of 1 ms.)
Influence of voltagePower-ON start: Β±0.01% Β±0.05 s max. (The values are based on the set value.) Signal start: Β±0.005% Β±3 ms max. (The values are based on the set value. The value is applied for a minimum pulse width of 1 ms.)
Influence of temperaturePower-ON start: Β±0.01% Β±0.05 s max. (The values are based on the set value.) Signal start: Β±0.005% Β±3 ms max. (The values are based on the set value. The value is applied for a minimum pulse width of 1 ms.)
Insulation resistanceBetween current carrying terminals and exposed non-current carrying metal parts: 100 MΞ© min. (at 500 VDC)
Dielectric strengthBetween current carrying metal parts and non-current carrying metal parts: 2000 VAC 50/60 Hz 1 min Between control output, and power supply/input circuit: 1000 VAC 50/60 Hz 1 min Between non-continuous contacts: 1000 VAC 50/60 Hz 1 min
Impulse withstand voltageBetween power terminals: 1.0 kV Between current carrying terminals and exposed non-current carrying metal parts: 1.5 kV
Noise immunityBetween power terminals: Β±480 kV Between input terminals: Β±600 kV square-wave noise by noise simulator, pulse width: 100 ns/1 Β΅s, 1-ns rise
Static immunityMulfunction: 8 kV, Destruction: 15 kV
Vibration resistanceDestruction: 10 to 55 Hz, 0.75 mm single amplitude each in 3 directions for 2 h Malfunction: 10 to 55 Hz 0.35 mm single amplitude each in 3 directions for 10 min
Shock resistanceDestruction: 300 m/s2, 3 times each in 3 axes each directions Malfunction: 100 m/s2, 3 times each in 6 directions
Degree of protectionIEC IP66, UL508 Type 4X (indoors) (when using the Y92S-29 Waterproof Packing and Y92F-30 Flush Mounting Adapter)
Case colorBlack (Munsell N1.5)
Accessory (sold separately)Soft Cover: Y92A-48F1 Hard Cover: Y92A-48 Flush mounting adapter: Y92F-30/Y92F-45/Y92F-38 Waterproof packing: Y92S-29 Replacement Front Panel: Y92P-CXT4S/Y92P-CXT4G/Y92P-CXT4B
Ambient temperature range-10 to 55 ℃ (with no freezing or condensation) When mount timer side by side: -10 to 50 ℃ (with no freezing or condensation)
No-voltage input (Solid state input)Short-circuit (ON) impedance: 1 kΞ© max. (Leakage current (0 Ξ©): Approx. 12 mA) Short-circuit (ON) residual voltage: 3 V max. Open circuit impedance: 100 kΞ© min. (The DC voltage must be 30 VDC max.)
No-voltage input (Contact input)Use contact which can adequately switch 5 mA at 10 V
No-voltage input (Applicable two-wire sensor)Leakage current: 1.5 mA max. Switching capacities: 5 mA min. Residual voltage: 3.0 VDC max. Operating voltage: 10 VDC
Voltage inputHigh level: 4.5 to 30 VDC Low level: 0 to 2 VDC (Input resistance 4.7 kΞ©)
Control output (Solid state output)2 pointTransistor output (NPN open collector) Switching capacities: 30 VDC max., 100 mA max. Residual voltage: 1.5 V (Capacity value 1 V) Leakage current: 0.1 mA max.
Power resetMinimum power-opening time: 0.5 s (except for A-3, b-1, F, ton-1 and toff-1 mode)
Key protect methodKey protect Switch
Memory backup methodEEP-ROM (number of writes: 100,000 operations min., Service life: 10 years min.)
AttachmentFlush mounting adapter, waterproof packing, label for DIP switch settings, terminal covers
WeightMain Unit: Approx. 105 g

Disclaimer: IndMALL serves solely as a platform connecting buyers and vendors. It does not participate in pricing, payment, or delivery of goods.
Buyers are advised to verify all details and deal directly with vendors before finalizing any transaction.