Procurement teams shortlist H3Y-2-AC100-120-10M with Omron SMPS 24V 10A, Omron H3Cr A8 Ac100 240 Dc100 125 and Autonics Timers, aligning budget approvals, warranty terms, and multisite availability for smoother rollout across plants.
Omron H3Y-2 AC100-120 10M Timer
The Omron H3Y-2 AC100-120 10M Timer is a reliable Power ON-delay timer designed with an allowable voltage variable range of 85 to 110% of the power supply voltage consumption of Approx. 1.5 VA (at 120 VAC). It supports a reset voltage of 1 and offers one selectable time range for consistent timing performance. This Time-limit: DPDT output model operates with Time-limit operation/Self-reset functionality. It features an connecting method and a Beige case color. Manufactured by Omron, listed in Omron Timers, and part of the H3Y Series

| Brand | Omron |
| Product | Timers |
| Model Number | H3Y-2 AC100-120 10M |
Omron H3Y-2 AC100-120 10M Timer - Technical Specifications
| Specification | Value |
|---|---|
| Rated power supply voltage | 100 to 120 VAC 50/60 Hz |
| Allowable voltage variable range | 85 to 110% of the power supply voltage |
| Reset voltage | 10% min, of rated supply voltage |
| Number of time ranges | 1 |
| Operation mode | Power ON-delay |
| Control output (Type) | Time-limit: DPDT |
| Control output (Contact output) | Resistive load: 250 VAC 5 A (cosΓβ =1) Minimum applicable load: 1 mA at 5 VDC (failure level: P) |
| Operating resetting | Time-limit operation/Self-reset |
| Connection method | 8-pin round socket |
| Power consumption | Approx. 1.5 VA (at 120 VAC) |
| Ambient temperature range | Operating: -10 to 50 β (with no icing) Storage: -25 to 65 β (with no icing) |
| Accuracy of operating time | Β±1% FS max. |
| Setting error | Β±10% FS Β±50 ms max. |
| Influence of voltage | Β±2% FS max. |
| Influence of temperature | Β±2% FS max. |
| Insulation resistance | 100 MΞ© min. (at 500 VDC) |
| Dielectric strength | Between current carrying terminals and exposed non-current carrying metal parts: 2000 VAC 50/60 Hz 1 min (Terminal screw sections are not excluded) Between operating power circuit and control output: 2,000 VAC 50/60 Hz 1 min Between contacts of different polarity: 2,000 VAC 50/60 Hz 1 min Between non-continuous contacts: 1,000 VAC 50/60 Hz 1 min |
| Impulse withstand voltage | Between power terminals: 3 kV Between current carrying terminals and exposed non-current carrying metal parts: 4.5 kV |
| Noise immunity | Β±1.5 kV square-wave noise by noise simulator (pulse width: 100 ns/1 Β΅s, 1-ns rise) |
| Static immunity | Mulfunction: 4 kV, Destruction: 8 kV |
| Vibration resistance | Destruction: 10 to 55 Hz, 0.75 mm single amplitude each in 3 directions for 1 hour Malfunction: 10 to 55 Hz, 0.5 mm single amplitude each in 3 directions for 10 min |
| Shock resistance | Destruction: 1,000 m/s2, 3 times each in 6 directions Malfunction: 100 m/s2, 3 times each in 6 directions |
| Degree of protection | IP40 |
| Case color | Beige |
| Ambient temperature range | Operating: -10 to 50 β (with no icing) Storage: -25 to 65 β (with no icing) |
| Ambient humidity range | Operating: 35 to 85% |
| Reset time | 0.1 s max. (including halfway reset) |
| Life expectancy (relay output) | Electrical: 500,000 operations min. (5 A at 250 VAC, resistive load at 1,800 operations/h, Room temperature) Mechanical: 10 million operations min. (under no load at 1,800 operations/h) |
| Weight | Approx. 50 g |