+91 79955 44066
IndMALL: B2B Marketplace - We Connect Buyers & Sellers for Industrial Products

Sick RLY3-OSSD200 Safety Relay

RLY3-OSSD200 1085344 Sick Dual Channel Safety Relay Technical Specifications

BrandSick
Product TypeSafety Relay
ProductRLY3-OSSD200

Sick RLY3-OSSD200 Safety Relay – Technical Specifications

SpecificationValue
Compatible sensor typesSafety sensors with OSSDs
Safety integrity levelSIL 3 (IEC 61508)
CategoryCategory 4 (ISO 13849-1)
Performance levelPL e (ISO 13849-1)
TM (mission time)20 years (ISO 13849-1)
Sensor monitoringSequence monitoring
Restart interlockβœ”
ResetAutomatic, Manual
External device monitoring (EDM)βœ”
Connection typeFront connector with spring terminals
Inputs2 safety inputs, 1 input for reset pushbutton or external device monitoring (EDM)
Outputs2 enabling current paths (safe), 2 application diagnostic outputs (not safe), 1 test pulse output (not safe)
Display elementsLEDs
Configuration methodHard wired
Supply voltage VS24 V DC (16.8 V ... 30 V)
Residual ripple≀ 2.4 V
Power consumption≀ 2.5 W (DC)
Input voltage HIGH24 V DC (11 V ... 30 V)
Input voltage LOW0 V DC (–3 V ... 5 V)
Input current4 mA ... 6 mA
Test pulse width≀ 1 ms
Test pulse rate≀ 10 Hz
Response time10 ms
Type of outputN/O contacts, positively guided
Contact materialSilver alloy, gold flashed
Switching voltage10 V AC ... 230 V AC, 10 V DC ... 230 V DC
Switching current10 mA ... 6 A
Total current12 A
Overvoltage categoryIII (EN 60664-1)
Rated impulse withstand voltage Uimp6 kV (EN 60664-1)
Output voltage HIGHβ‰₯ Vs – 3 V
Output voltage LOW≀ 3 V
Input current (NPN)≀ 15 mA
Output current (PNP)≀ 120 mA
Output voltageβ‰₯ Vs – 3 V
Test pulse interval40 ms
Dimensions (W x H x D)18 mm x 124.6 mm x 85.5 mm
Enclosure ratingIP20 (IEC 60529)
Ambient operating temperature–25 Β°C ... +55 Β°C
Storage temperature–25 Β°C ... +70 Β°C
Air humidity≀ 95 %, Non-condensing
Interference emissionAccording to IEC 61000-6-4
Interference resistanceAccording to IEC 61326-3-1, According to IEC 61000-6-2, According to IEC 60947-5-1
Weight130 g
Give Us a Call for Sick Dual Channel Safety Relay RLY3-OSSD200 part no: 1085344 at the lowest pricing. In-depth Technical Analysis of RLY3-OSSD200, 1085344 features Safety sensors with OSSDs and meets SIL 3 (IEC 61508), Category 4 (ISO 13849-1) and PL e (ISO 13849-1) standards with a 20 years (ISO 13849-1) mission time. It features Sequence monitoring, Automatic, Manual reset. The relay has a Front connector with spring terminals, 2 safety inputs, 1 input for reset pushbutton or external device monitoring (EDM). Outputs include 2 enabling current paths (safe), 2 application diagnostic outputs (not safe), 1 test pulse output (not safe) and LEDs for display elements and is configured through a Hard wired method. It supports 24 V DC (16.8 V ... 30 V) supply voltage, ≀ 2.4 V residual ripple, and ≀ 2.5 W (DC) power consumption. The relay operates with input voltage high at 24 V DC (11 V ... 30 V) and low at 0 V DC (–3 V ... 5 V), with an input current of 4 mA ... 6 mA . The test pulse width is ≀ 1 ms, and the test pulse rate is ≀ 10 Hz, with a response time of 10 ms. The relay has N/O contacts, positively guided, Silver alloy, gold flashed supporting 10 V AC ... 230 V AC, 10 V DC ... 230 V DC switching voltage, and 10 mA ... 6 A switching current and a total current of 12 A. Output voltage HIGH is β‰₯ Vs – 3 V, and output voltage LOW is ≀ 3 V. The input current (NPN) is ≀ 15 mA, and the output current (PNP) is ≀ 120 mA, with an output voltage of β‰₯ Vs – 3 V and a test pulse interval of 40 ms. The dimensions of 18 mm x 124.6 mm x 85.5 mm and an IP20 (IEC 60529) enclosure rating. It operates in ambient temperatures of –25 Β°C ... +55 Β°C and storage temperatures of –25 Β°C ... +70 Β°C, with air humidity of ≀ 95 %, Non-condensing. Elevate Your Project with a Quote for your requirement of Sick RLY3-OSSD200 Safety Relay. Our promise: More affordable pricing and more personalized support than other Distributors & Dealers.