Many engineers reviewing Phoenixcontact PHOENIX-CONTACT-PSR-SCP-24UC-ESAM4-2X1-1X2-SET10 also explore SMPS Phoenix, Sick Safety Relay and Phoenixcontact Phoenix Contact Psr Scp 24Uc Esl4 3X1 1X2 B, ensuring they donβt miss strong alternatives before finalizing procurement decisions.
Phoenix Contact PSR-SCP- 24UC/ESAM4/2X1/1X2-SET10 - 1449148 - Safety relays
Technical Specifications of Safety relays PSR-SCP- 24UC/ESAM4/2X1/1X2-SET10 1449148

| Brand | Phoenix Contact |
| Product Type | Safety Relays |
| Product | PSR-SCP- 24UC/ESAM4/2X1/1X2-SET10 |
Phoenix Contact Safety relays PSR-SCP- 24UC/ESAM4/2X1/1X2-SET10, 1449148 Technical Specifications
| Specification | Value |
|---|---|
| Note on application | Only for industrial use |
| Product type | Safety relays |
| Product family | PSRclassic |
| Application | Emergency stop |
| Control | 2-channel |
| Mechanical service life | approx. 107 cycles |
| Relay type | Electromechanical relay with force-guided contacts in accordance with IEC/EN 61810-3 |
| Overvoltage category | III |
| Degree of pollution | 2 |
| Typical response time | typ. 150 ms (For Us autostart) |
| Typ. starting time with Us | typ. 250 ms (with Us / when controlled via A1) |
| Typical release time | typ. 20 ms (At Us on demand via sensor circuit) |
| Recovery time | < 1 s (Boot time) |
| Maximum power dissipation for nominal condition | 16.44 W (US = 26.4 V, ILΒ² = 72 AΒ², PTotal max = 2.04 W + 14.4 W) |
| Nominal operating mode | 100% operating factor |
| Rated insulation voltage | 250 V |
| Description of the input | non-safety-related |
| Number of inputs | 2 |
| Input voltage range "1" signal | 20.4 V ... 26.4 V |
| Inrush current | min. 10 mA; max. 6 A |
| Filter time | No test pulses permitted |
| Max. permissible overall conductor resistance | 50 Ξ© |
| Protective circuit | Suppressor diode |
| Current consumption | 0 mA (typ. with US at S34) |
| Output description | 2 N/C contacts parallel, non-safety-related, floating |
| Number of outputs | 1 |
| Contact switching type | 1 signaling current path |
| Contact material | AgSnO2 |
| Switching voltage | min. 10 V AC/DC |
| Switching capacity | min. 100 mW |
| Limiting continuous current | 6 A (Signaling current path) |
| Sq. Total current | 36 A2 |
| Switching frequency | max. 0.5 Hz |
| Interrupting rating (ohmic load) max. | Observe derating and load limit curve |
| Output fuse | 6 A gL/gG |
| pluggable | yes |
| Connection method | Screw connection |
| Conductor cross section rigid | 0.2 mmΒ² ... 2.5 mmΒ² |
| Conductor cross section flexible | 0.2 mmΒ² ... 2.5 mmΒ² |
| Conductor cross-section AWG | 24 ... 12 |
| Stripping length | 7 mm |
| Screw thread | M3 |
| Status display | 3 x LED (green) |
| Operating voltage display | 1 x LED (green) |
| Width | 22.5 mm |
| Height | 99 mm |
| Depth | 114.5 mm |
| Color (Housing) | yellow (RAL 1018) |
| Housing material | PA |
| Category | 4 |
| Performance level (PL) | e (5 A DC13; 5 A AC15; 8760 switching cycles/year) |
| Safety Integrity Level (SIL) | 3 |
| Degree of protection | IP20 |
| Min. degree of protection of inst. location | IP54 |
| Ambient temperature (operation) | -20 Β°C ... 55 Β°C (observe derating) |
| Ambient temperature (storage/transport) | -40 Β°C ... 70 Β°C |
| Maximum altitude | β€ 2000 m (Above sea level) |
| Max. permissible humidity (storage/transport) | 75 % (on average, 85% infrequently, non-condensing) |
| Max. permissible relative humidity (operation) | 75 % (on average, 85% infrequently, non-condensing) |
| Shock | 15g |
| Vibration (operation) | 10 Hz ... 150 Hz, 2g |
| Identification | CE-compliant |
| Mounting type | DIN rail mounting |
| Mounting position | vertical or horizontal |
| Rated control circuit supply voltage US | 24 V DC -15 % / +10 % |
| Rated control supply current IS | typ. 70 mA (at US) |
| Power consumption at US | typ. 1.68 W |
| Input voltage range "0" signal | 0 V DC ... 5 V DC (S12) |
| Input current range "0" signal | 0 mA ... 2 mA |
| Concurrence | β |
| Assembly note | See derating curve |