In sourcing discussions, PHOENIX-CONTACT-PSR-SPP-24UC-THC4-2X1-1X2 is often placed next to SMPS Phoenix, Sick Safety Relay and Phoenixcontact Phoenix Contact Psr Scp 24Uc Esl4 3X1 1X2 B so procurement teams can align budgets and technical requirements effectively.
Phoenix Contact PSR-SPP- 24UC/THC4/2X1/1X2 - 2963983 - Safety relays
Technical Specifications of Safety relays PSR-SPP- 24UC/THC4/2X1/1X2 2963983

| Brand | Phoenix Contact |
| Product Type | Safety Relays |
| Product | PSR-SPP- 24UC/THC4/2X1/1X2 |
Phoenix Contact Safety relays PSR-SPP- 24UC/THC4/2X1/1X2, 2963983 Technical Specifications
| Specification | Value |
|---|---|
| Note on application | Only for industrial use |
| Product type | Safety relays |
| Product family | PSRclassic |
| Application | Two-hand control |
| Mechanical service life | approx. 107 cycles |
| Relay type | Electromechanical relay with force-guided contacts in accordance with IEC/EN 61810-3 |
| Overvoltage category | III |
| Degree of pollution | 2 |
| Typical response time | 50 ms |
| Typical release time | 20 ms |
| Recovery time | 1 s |
| Maximum power dissipation for nominal condition | 1.44 W |
| Nominal operating mode | 100% operating factor |
| Rated insulation voltage | 250 V |
| Rated surge voltage/insulation | 6 kV / Safe isolation, increased insulation |
| Protective circuit | Fuse; PTC resistor |
| Output description | safety-related N/O contacts |
| Number of outputs | 2 |
| Contact switching type | 2 enabling current paths |
| Contact material | AgSnO2, + 0.2 Β΅m Au |
| Limiting continuous current | 6 A (N/O contact) |
| Interrupting rating (ohmic load) max. | 144 W (24 V DC, Ο = 0 ms) |
| Maximum interrupting rating (inductive load) | 42 W (24 V DC, Ο = 40 ms) |
| Output fuse | 10 A gL/gG NEOZED (N/O contact) |
| pluggable | yes |
| Connection method | Push-in connection |
| Conductor cross section rigid | 0.2 mmΒ² ... 1.5 mmΒ² |
| Conductor cross section flexible | 0.2 mmΒ² ... 1.5 mmΒ² |
| Conductor cross-section AWG | 24 ... 16 |
| Stripping length | 8 mm |
| Status display | LED (green) |
| Operating voltage display | Green LED |
| Width | 22.5 mm |
| Height | 112 mm |
| Depth | 114.5 mm |
| Color (Housing) | yellow (RAL 1018) |
| Housing material | PA |
| Category | 4 |
| Performance level (PL) | e |
| Safety Integrity Level (SIL) | 3 |
| Degree of protection | IP20 |
| Min. degree of protection of inst. location | IP54 |
| Ambient temperature (operation) | -20 Β°C ... 55 Β°C |
| Ambient temperature (storage/transport) | -40 Β°C ... 70 Β°C |
| Maximum altitude | max. 2000 m (Above sea level) |
| Max. permissible humidity (storage/transport) | 75 % (on average, 85% infrequently, non-condensing) |
| Max. permissible relative humidity (operation) | 75 % (on average, 85% infrequently, non-condensing) |
| Shock | 15g |
| Vibration (operation) | 10 Hz ... 150 Hz, 2g |
| Mounting type | DIN rail mounting |
| Mounting position | any |
| Concurrence | < 0.5 s |
| Voltage at input/start and feedback circuit | approx. 24 V DC |
| Maximum switching voltage | 250 V AC/DC |
| Minimum switching voltage | 15 V AC/DC |
| Maximum inrush current | 6 A |
| Inrush current, minimum | 25 mA |
| Switching capacity min. | 0.4 W |
| Switching capacity (360/h cycles) | 4 A (24 V DC) |
| Switching capacity (3600/h cycles) | 2.5 A (24 V (DC13)) |
| Nominal input voltage UN | 24 V AC/DC |
| Input voltage range | 20.4 V AC/DC ... 26.4 V AC/DC |
| Input voltage range in reference to UN | 0.85 ... 1.1 |
| Typical input current at UN | 125 mA AC |
| Type class | IIIC |
| Conformance | CE-compliant |
| Conductor cross section, flexible, with ferrule, with plastic sleeve | 0.25 mmΒ² ... 1.5 mmΒ² (only together with CRIMPFOX 6) |
| Conductor cross section flexible, with ferrule without plastic sleeve | 0.25 mmΒ² ... 1.5 mmΒ² (only together with CRIMPFOX 6) |