Standard nominal flow rate (standardised to DIN 1343)
1200
pneumatic working port
Sub-base size 1 to ISO 5599-1; G1/4
Operating pressure
-0.9; 16
Design
Piston gate valve
Nominal size
8
Grid dimension
43
Exhaust-air function
With flow control option
Sealing principle
Soft
Mounting position
optional
Conforms to standard
ISO 5599-1
Manual override
None
ISO code
101
Type of piloting
Direct
Flow direction
Reversible
Symbol
991037
lap
Overlap
Pilot pressure
2; 16
Switching time reversal
6
Explosion protection
Zone 1 (ATEX); Zone 1 (UKEX); Zone 2 (ATEX); Zone 21 (ATEX); Zone 21 (UKEX); Zone 22 (ATEX)
Operating medium
Compressed air to ISO 8573-1:2010 [7:4:4]
Note on operating and pilot medium
Lubricated operation possible (in which case lubricated operation will always be required)
Vibration resistance
Transport application test with severity level 1 to FN 942017-4 and EN 60068-2-6
Shock resistance
Shock test with severity level 2 to FN 942017-5 and EN 60068-2-27
LABS (PWIS) conformity
VDMA24364-B1/B2-L
Media temperature
-10; 60
Sound pressure level
85
Pilot medium
Compressed air to ISO 8573-1:2010 [7:4:4]
Ambient temperature
-10; 60
Product weight
290
Type of mounting
On sub-base; With through-hole
Material seals
HNBR; NBR
Material housing
Die-cast aluminium