In sourcing discussions, KN-1041B is often placed next to Autonics Proximity Sensor, Autonics Digital Counter and Autonics Kn 1000B so procurement teams can align budgets and technical requirements effectively.
Autonics KN-1041B Indicator
The Autonics KN-1041B Indicator offers JPt100Ξ©, DPt100Ξ©, DPt50Ξ©, Cu50Ξ©, Cu100Ξ© (5 types) input type, K, J, E, T, R, B, S, N, C (W5), L, U, PLII (12 types), 24VDC power supply. Manufactured by Autonics under the Autonics Indicators category, this model belongs to the Autonics KN Series.

| Brand | Autonics |
| Product Type | Indicators |
| Model Number | KN-1041B |
Autonics KN-1041B Indicator β Technical Specifications
| Specification | Value |
|---|---|
| Power supply_DC power | 24VDC |
| Input type_RTD | JPt100Ξ©, DPt100Ξ©, DPt50Ξ©, Cu50Ξ©, Cu100Ξ© (5 types) |
| Input type_TC | K, J, E, T, R, B, S, N, C (W5), L, U, PLII (12 types) |
| Input type_Analog | Β· Voltage: Β±1.000V, Β±50.00mV, -199.9-200.0mV, -1.00-10.00V (4 types)Β· Current: 4.00-20.00mA, 0.00-20.00mA (2 types) |
| Auxiliary output_Communication output | RS485 (ModBus RTU) |
| Display accuracy | Β±0.2% F.S. Β±1-digit (25βΒ±5β)Β±0.3% F.S. Β±1-digit ( 10β to 20β, 30β to 50β)In case of thermocouple and below -100ΛC input, [ Β±0.4%F.S. ] Β±1-digitβ»TC-T, TC-U is min. Β±2.0β |
| Environment_Ambient temperature | -10 to 50β, storage: -20 to 60β |
| Environment_Ambient humidity | 35 to 85% RH, storage: 35 to 85% RH |
| Weight | Approx. 304g (approx. 182g) |
Obtain a Quote for Autonics Bar Graph Temperature Indicators KN-1041B at economical prices. Specifications Overview for KN-1041B reveals Supporting RTD inputs like JPt100Ξ©, DPt100Ξ©, DPt50Ξ©, Cu50Ξ©, Cu100Ξ© (5 types), and thermocouple (TC) inputs including K, J, E, T, R, B, S, N, C (W5), L, U, PLII (12 types), these controllers ensure versatile temperature measurement. Analog inputs range from Β· Voltage: Β±1.000V, Β±50.00mV, -199.9-200.0mV, -1.00-10.00V (4 types)Β· Current: 4.00-20.00mA, 0.00-20.00mA (2 types). Display accuracy is Β±0.2% F.S. Β±1-digit (25βΒ±5β)Β±0.3% F.S. Β±1-digit ( 10β to 20β, 30β to 50β)In case of thermocouple and below -100ΛC input, [ Β±0.4%F.S. ] Β±1-digitβ»TC-T, TC-U is min. Β±2.0β has an accuracy. Operating conditions include an ambient temperature range of -10 to 50β, storage: -20 to 60β and humidity between 35 to 85% RH, storage: 35 to 85% RH. With a weight of Approx. 304g (approx. 182g), these controllers ensure reliable performance. Take the First Step with a Quote for your requirement of Bar Graph Temperature Indicators. Our commitment to better pricing and exceptional support sets us apart from other Competitors.