Can reach PL = e with the appropriate monitoring system and correctly wired conforming to EN/ISO 13849-1,
can reach category 4 with the appropriate monitoring system and correctly wired conforming to EN/ISO 13849-1,
can reach SIL 3 with the appropriate monitoring system and correctly wired conforming to EN/IEC 61508
Safety reliability data
B10d = 300000 conforming to IEC 60947-5-5 value given for a life time of 20 years limited by mechanical or contact wear
Marking
CE
Positive opening
With conforming to EN/IEC 60947-5-1
Resistance across terminals
25 MOhm conforming to EN/IEC 60255-7 category 3
Terminals description ISO nΒ°1
(13-14)NO
Standards
Work equipment directive 2009/104/EC
Product certifications
UL category NISD emergency stop devices,
CSA,
CCC,
EAC
Protective treatment
TC
Vibration resistance
10 gn (f= 10-300 Hz) conforming to EN/IEC 60068-2-6