Many procurement teams check DRP012V030W1AZ against Weidmuller Power Supply, Delta VFD and Delta Drl 24V480W1En before signing purchase orders, verifying quality, compliance, and after-sales support availability.
Delta DRP012V030W1AZ - DIN Rail CliQ Series
Technical Specifications of Delta DRP012V030W1AZ DIN Rail CliQ Series

| Brand | Delta |
| Product Type | SMPS |
| Product | DRP012V030W1AZ |
Delta DIN Rail CliQ Series DRP012V030W1AZ Technical Specifications:
| Specification | Value |
|---|---|
| Output Current | 2.5A |
| Output Voltage | 12V |
| Output Voltage Adjustment Range | 11-14Vdc |
| Output Power | 30W |
| Line Regulation | < 0.5% (@ 85-264Vac input, 100% load) |
| Load Regulation | < 1.0% (@ 85-264Vac input, 0-100% load) |
| PARD | < 100mVpp |
| Start-up Time | < 2,500ms @ nominal input (100% load) |
| Hold-up Time | > 22ms @ 115Vac, > 110ms @ 230Vac (100% load) |
| Dynamic Response (Overshoot & Undershoot O/P Voltage) | ± 5% @ 85-264Vac input, 0-100% load (Slew Rate: 0.1A/μs, 50% duty cycle @ 5Hz to 1KHz) |
| Start-up with Capacitive Loads | 6,600µF Max |
| Rise Time | < 20ms @ nominal input (100% load) |
| Nominal Input Voltage | 100-240Vac |
| Input Voltage Range | 85-264Vac |
| Nominal Input Frequency | 50-60Hz |
| Input Frequency Range | 47-63Hz |
| DC Input Voltage Range | 120-375Vdc |
| Input Current | < 0.70A @ 115Vac, < 0.42A @ 230Vac |
| Efficiency at 100% load | > 85.0% @ 115Vac & 230Vac |
| Inrush Current | < 40A @ 115Vac < 80A @ 230Vac |
| Leakage Current | < 1mA @ 240Vac |
| Power Dissipation | 0% load: < 0.5W @ 115Vac, < 1.0W @ 230Vac 100% load: < 5.3W @ 115Vac & 230Vac |
| Case Chassis / Cover | Plastic |
| Indicator | Green LED (DC OK) |
| Cooling System | Convection |
| Noise Sound Pressure Level (SPL) | < 40dBA |
| Input/Output Terminal | 5 Pins (Rated 300V/15A) |
| Mounting Rail | Standard TS35 DIN Rail in accordance with EN 60715 |
| Wire | Input / Output: AWG 20-14 |
| Unit Weight | 0.20 kg (0.44 lb) |
| Operating Temperature | -20°C to +80°C |
| Storage Temperature | -25°C to +85°C |
| Power De-rating | Vertical / Horizontal: > 50°C de-rate power by 2.5% / °C, > 70°C de-rate power by 4% / °C |
| Operating Humidity | 5 to 95% RH (Non-Condensing) |
| Shock Test (Non-Operating) | IEC 60068-2-27, 30G (300m/S²) for a duration of 18ms, 3 times per direction, 18 times in total |
| Vibration (Non-Operating) | IEC60068-2-6, 10Hz to 150Hz @ 50m/S² (5G peak); 90 min per axis for all X, Y, Z direction |
| Operating Altitude | 0 to 2,000 Meters (6,560 ft.) |
| Pollution Degree | 2 |
| Over Voltage Category | III According to IEC/EN 62477-1 (clearance and creepage distances) |
Mail Us for your needs in Delta DIN Rail CliQ Series DRP012V030W1AZ with budget-friendly prices. The Main Technical Parameters of DRP012V030W1AZ include 2.5A Output Current, 12V Output Voltage, 30W Output Power at competitive prices. It operates with a nominal input voltage of 100-240Vac and supports an input voltage range of 85-264Vac. The power supply covers a nominal input frequency of 50-60Hz, with a broader input frequency range of 47-63Hz. With an input current of < 0.70A @ 115Vac, < 0.42A @ 230Vac, it ensures efficient performance. The unit features a Green LED (DC OK) indicator, aiding in quick status checks for secure connections. Designed for extreme environments, it Operating Temperature from -20°C to +80°C and has a storage temperature of -25°C to +85°C. Customize Your Experience with a Quote for your requirement of DIN Rail CliQ Series. Experience the difference with our competitive pricing and superior support over other Suppliers.