Before procurement teams confirm DRS-5V30W1NZ, they typically review Weidmuller Power Supply, Delta VFD and Delta Drl 24V480W1En to double-check performance ratings, stock availability, and supplier credibility carefully.
DRS-5V30W1NZ - Delta 3A 5V DIN Rail Power Supply
Technical Specifications of Delta DRS-5V30W1NZ 3A 5V DIN Rail Power Supply

| Brand | Delta |
| Product Type | SMPS |
| Product | DRS-5V30W1NZ |
Delta 3A 5V DIN Rail Power Supply DRS-5V30W1NZ Technical Specifications:
| Specification | Value |
|---|---|
| Output Current | 3A |
| Output Voltage | 5V |
| Output Voltage Adjustment Range | 5.0-5.5Vdc |
| Output Power | 15W |
| Line Regulation | < 0.5% (@ 85-264Vac, 100% load) |
| Load Regulation | < 1.0% (@ 85-264Vac, 0-100% load) |
| PARD | < 75mVpp @ > 0°C to 70°C < 150mVpp @ 0°C to -20°C |
| Start-up Time | < 2,000ms @ 115Vac (100% load) < 1,000ms @ 230Vac (100% load) |
| Hold-up Time | > 20ms @ 115Vac (100% load) > 100ms @ 230Vac (100% load) |
| Dynamic Response (Overshoot & Undershoot O/P Voltage) | ± 5% @ 85-264Vac input, 5-100% load (Slew Rate: 0.1A/μS, 50% duty cycle @ 5Hz to 1KHz) |
| Start-up with Capacitive Loads | 3,000μF Max |
| Nominal Input Voltage | 100-240Vac |
| Input Voltage Range | 85-264Vac |
| Nominal Input Frequency | 50-60Hz |
| Input Frequency Range | 47-63Hz |
| DC Input Voltage Range | 120-375Vdc |
| Input Current | < 0.40A @ 115Vac, < 0.20A @ 230Vac |
| Efficiency at 100% load | > 79.0% @ 115Vac & 230Vac |
| Inrush Current | < 20A @ 115Vac, < 40A @ 230Vac |
| Leakage Current | IEC/EN 60950-1: < 0.5mA @ 264Vac IEC/EN 62368-1: < 1.0mA @ 264Vac |
| Power Dissipation | - |
| Case Chassis / Cover | Plastic |
| Indicator | - |
| Cooling System | Convection |
| Unit Weight | 0.11 kg (0.24 lb) |
| Vibration (Operating) | IEC 60068-2-6, Sine Wave: 10-500Hz; 2G peak; displacement of 0.35mm; 1 octave per min; 60 min per axis for all X, Y, Z directions |
| Shock Test (Operating) | IEC 60068-2-27, Half Sine Wave: 10G for a duration of 11ms; 1 time in X axis |
| Operating Temperature | -20°C to +70°C (Cold start at -40°C @ 40% load) |
| Storage Temperature | -40°C to +85°C |
| Power De-rating | -10°C to -20°C de-rate power by 2% / °C > 55°C de-rate power by 3.33% / °C |
| Operating Humidity | 5 to 95% RH (Non-Condensing) |
| Shock Test (Non-Operating) | IEC60068-2-27, Half Sine Wave: 50G for a duration of 11ms; 3 times per direction, 9 times in total |
| Vibration (Non-Operating) | IEC 60068-2-6, Random: 5-500Hz; 2.09Grms, 20 min per axis for all X, Y, Z directions |
Call us for Delta 3A 5V DIN Rail Power Supply DRS-5V30W1NZ at the best rates. Technical Attributes of DRS-5V30W1NZ are 3A Output Current, 5V Output Voltage, 15W Output Power at competitive prices. It operates with a nominal input voltage of 100-240Vac and supports an input voltage range of 85-264Vac. The power supply covers a nominal input frequency of 50-60Hz, with a broader input frequency range of 47-63Hz. With an input current of < 0.40A @ 115Vac, < 0.20A @ 230Vac, it ensures efficient performance. The unit features a - indicator, aiding in quick status checks for secure connections. Designed for extreme environments, it Operating Temperature from -20°C to +70°C (Cold start at -40°C @ 40% load) and has a storage temperature of -40°C to +85°C. Unlock Exclusive Pricing with a Quote for your requirement of 3A 5V DIN Rail Power Supply. Trust in our ability to provide more advantageous pricing and dedicated support beyond other other Dealers.