+91 79955 44066
IndMALL: B2B Marketplace - We Connect Buyers & Sellers for Industrial Products

DRM-24V480W1SN - Delta 24V 480W DIN Rail Power Supply

Technical Specifications of Delta DRM-24V480W1SN 24V 480W DIN Rail Power Supply

BrandDelta
Product TypeSMPS
ProductDRM-24V480W1SN

Delta24V 480W DIN Rail Power Supply DRM-24V480W1SN Technical Specifications:

SpecificationValue
Output Current20A
Output Voltage24V
Output Voltage Adjustment Range24-28 Vdc (multi-turn VR)
Output Power480W
Line Regulation< 10 mV (@ 85-276 Vac input, 100% load)
Load Regulation< 4.2% (1 V) @ 85-276 Vac input, 0-100% load)
PARD< 120 mVpp
Start-up Time< 1,000 ms @ 100 Vac & 120 Vac & 230 Vac
Hold-up Time78 ms typ. @ 100 Vac & 120 Vac & 230 Vac (24 V, 10 A) 38 ms typ. @ 100 Vac & 120 Vac & 230 Vac (24 V, 20 A)
Dynamic Response (Overshoot & Undershoot O/P Voltage)± 5% @ 0-100% load Slew rate 0.1 A/µs (@ 5 Hz, 50 Hz & 1 kHz, 50% Duty Cycle)
Start-up with Capacitive Loads20,000 µF Max
Rise Time< 100 ms @ 100 Vac & 120 Vac & 230 Vac
Power Boost Duration5 seconds typ. 7 seconds max.
Power Boost Recovery Time17 seconds typ.
Nominal Input Voltage100-240 Vac
Input Voltage Range85-276 Vac
Nominal Input Frequency50-60 Hz
Input Frequency Range-
Nominal DC Input Voltage110-300Vdc
DC Input Voltage Range88-375 Vdc (Continuously operating)
Input Current5.19 A typ. @ 100 Vac 4.31 A typ. @ 120 Vac 2.31 A typ. @ 230 Vac
Efficiency at 100% load92.58% typ. @ 100 Vac 93.23% typ. @ 120 Vac 93.78% typ. @ 230 Vac
Inrush Current< 13 A @ 100 Vac & 120 Vac & 230 Vac
Power Factor at 100% load0.99 typ. @ 100 Vac 0.99 typ. @ 120 Vac 0.96 typ. @ 230 Vac
Leakage Current(Enclosure to Neutral) < 0.40 mA / 0.40 mA @ 110 Vac, 50 Hz, TN/TT system / IT system < 0.48 mA / 0.50 mA @ 132 Vac, 50 Hz, TN/TT system / IT system < 1.10 mA / 1.20 mA @ 264 Vac, 50 Hz, TN/TT system / IT system
Power DissipationAt 24 V, 0 A: < 9.00 W @ 100 Vac < 9.20 W @ 120 Vac < 10.00 W @ 230 Vac At 24 V, 20 A: < 44.00 W @ 100 Vac < 39.60 W @ 120 Vac < 33.00 W @ 230 Vac
Case Chassis / CoverAluminium
IndicatorGreen LED: DC OK Red LED: Overload
Cooling SystemConvection
Input Terminal3 Pins (Rated 600 V / 35 A)
Output Terminal4 Pins (Rated 300 V / 30 A)
Noise Sound Pressure Level (SPL)< 25 dBA
Mounting RailStandard TS35 DIN Rail in accordance with EN 60715
WireInput: AWG 18-8 Output: AWG 14-10 Signal: AWG 20-12
Unit Weight1.40 kg (3.09 lb)
Operating Temperature-25°C to +70°C (Cold start -40°C)
Storage Temperature-40°C to +85°C
Power De-ratingVertical Mounting: > 60°C de-rate power by 2.5% / °C Horizontal Mounting: > 40°C de-rate power by 2.5% / °C
Operating Humidity5 to 95% RH (Non-Condensing)
Shock Test (Non-Operating)IEC 60068-2-27, Half Sine Wave: 30 G for a duration of 18 ms; 3 times per direction, 6 times in total
Vibration (Non-Operating)IEC 60068-2-6, Sine Wave: 10-500 Hz; 3 G peak; displacement of 0.35 mm; 60 min per axis for all X, Y, Z directions
Operating AltitudeOVC III: 0 to 2,500 Meters (8,200 ft.) OVC II: 0 to 5,000 Meters (16,400 ft.)
Pollution Degree2
Bump Test (Operating)IEC 60068-2-29, Half Sine Wave: 10 G for a duration of 11 ms, 1,000 times per direction, 6,000 times in total
Over Voltage CategoryIEC/EN 62477-1, EN 60204-1, IEC 62103 OVC III: 0 to 2,500 Meters (8,200 ft.) OVC II: 0 to 5,000 Meters (16,400 ft.) IEC/EN 60950-1, IEC/EN 62368-1, IEC 61010-1, IEC 61010-2-201 OVC II: 0 to 5,000 Meters (16,400 ft.)
Signal Terminal2 Pins (Rated 300 V / 28 A)
Call us for Delta 24V 480W DIN Rail Power Supply DRM-24V480W1SN at the best rates. Technical Attributes of DRM-24V480W1SN are 20A Output Current, 24V Output Voltage, 480W Output Power at competitive prices. It operates with a nominal input voltage of 100-240 Vac and supports an input voltage range of 85-276 Vac. The power supply covers a nominal input frequency of 50-60 Hz, with a broader input frequency range of -. With an input current of 5.19 A typ. @ 100 Vac 4.31 A typ. @ 120 Vac 2.31 A typ. @ 230 Vac, it ensures efficient performance. The unit features a Green LED: DC OK Red LED: Overload indicator, aiding in quick status checks. Both input and output terminals have 3 Pins (Rated 600 V / 35 A) and 4 Pins (Rated 300 V / 30 A) for secure connections. Designed for extreme environments, it Operating Temperature from -25°C to +70°C (Cold start -40°C) and has a storage temperature of -40°C to +85°C. Unlock Exclusive Pricing with a Quote for your requirement of 24V 480W DIN Rail Power Supply. Trust in our ability to provide more advantageous pricing and dedicated support beyond other other Dealers.

Disclaimer: IndMALL serves solely as a platform connecting buyers and vendors. It does not participate in pricing, payment, or delivery of goods.
Buyers are advised to verify all details and deal directly with vendors before finalizing any transaction.