+91 79955 44066
IndMALL: B2B Marketplace - We Connect Buyers & Sellers for Industrial Products

Schneider ATV6A0C31Q4 Variable Speed Drive

The Schneider ATV6A0C31Q4 Variable Speed Drive offers a 315.0 kW at 400 V normal duty250.0 kW at 400 V heavy duty motor power, 2-wire RS 485 for Modbus serial, 3 phases. Manufactured by Schneider under the Schneider Variable Speed Drive (VSD) category, this model belongs to the ATV600 Series.

BrandSchneider
Product TypeVFD(Variable Frequency Drive)
ProductATV6A0C31Q4

Schneider ATV6A0C31Q4 Variable Speed Drive – Technical Specifications

SpecificationValue
Degree of protection-
Supply frequency50...60 Hz - 5...5 %
Vibration resistance1.5 mm peak to peak (f= 2…13 Hz) conforming to IEC 60068-2-60.5 gn (f= 13…200 Hz) conforming to IEC 60068-2-6
IP degree of protectionIP00 (for IP21 or IP54 cabinet integration) conforming to IEC 61800-5-1IP00 (for IP21 or IP54 cabinet integration) conforming to IEC 60529
Speed drive output frequency0…500 Hz
Electromagnetic compatibilityElectrostatic discharge immunity test level 3 conforming to IEC 61000-4-2Radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-41.2/50 µs - 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5Conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6
Product or component typeVariable speed drive
Output voltage<= power supply voltage
Asynchronous motor control profileConstant torque standardVariable torque standardOptimized torque mode
Mounting modeCabinet mount
Ambient air temperature for storage-40…70 °C
Continuous output current590.0 A at 2.5 kHz normal duty477.0 A at 2.5 kHz heavy duty
Relay output typeConfigurable relay logic R1: fault relay NO/NC electrical durability 100000 cyclesConfigurable relay logic R2: sequence relay NO electrical durability 100000 cyclesConfigurable relay logic R3: sequence relay NO electrical durability 100000 cycles
Minimum switching currentRelay output R1, R2, R3: 5 mA at 24 V DC
Electrical connectionControl: removable screw terminals 0.5...1.5 mm²/AWG 20...AWG 16Line side: screw terminalMotor: M10 x 2 bars
Synchronous motor control profilePermanent magnet motor
Physical interface2-wire RS 485 for Modbus serial
Pollution degree2 conforming to IEC 61800-5-1
Type of polarizationNo impedance for Modbus serial
Product destinationSynchronous motorsAsynchronous motors
Number of preset speeds16 preset speeds
Operating altitude<= 1000 m without derating1000...4800 m with current derating 1 % per 100 m
Apparent power373 kVA at 400 V normal duty299 kVA at 400 V heavy duty
[Us] rated supply voltage400 V - 15...10 %
Ambient air temperature for operation-10…40 °C without derating40…50 °C with derating factor
SupplyExternal supply for digital inputs: 24 V DC (19…30 V), <1.25 mA, protection type: overload and short-circuit protectionInternal supply for reference potentiometer (1 to 10 kOhm): 10.5 V DC +/- 5 %, <10 mA, protection type: overload and short-circuit protectionInternal supply for digital inputs and STO: 24 V DC (21…27 V), <200 mA, protection type: overload and short-circuit protection
Switching frequency2.5...8 kHz with derating factor2...8 kHz adjustable
Motor power kW315.0 kW at 400 V normal duty250.0 kW at 400 V heavy duty
EMC filterIntegrated with 300 m conforming to IEC 61800-3 category C3
Communication port protocolEthernetModbus serialModbus TCP
Analogue input typeAI1, AI2, AI3 software-configurable voltage: 0...10 V DC, impedance: 30 kOhm, resolution 12 bitsAI1, AI2, AI3 software-configurable current: 0...20 mA/4...20 mA, impedance: 250 Ohm, resolution 12 bits
Maximum switching currentRelay output R1, R2, R3 on resistive load, cos phi = 1: 3 A at 250 V ACRelay output R1, R2, R3 on resistive load, cos phi = 1: 3 A at 30 V DCRelay output R1, R2, R3 on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 250 V ACRelay output R1, R2, R3 on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 30 V DC
Range of productAltivar Process ATV600
Shock resistance7 gn for 11 ms conforming to IEC 60068-2-27
Power dissipation in WForced convection: 9030 W, switching frequency 2.5 kHz (normal duty)Forced convection: 6630 W, switching frequency 2.5 kHz (heavy duty)
Nominal switching frequency2.5 kHz
Motor power hp-
Network number of phases3 phases
Submit your inquiry for the 315 kW Schneider VFD ATV6A0C31Q4 and explore our cost-effective solutions. This VFD, part of the Altivar Process ATV600 range, is equipped with advanced specifications to meet diverse application needs. It operates at a supply frequency of 50...60 Hz with a -5...+5 % tolerance and supports an output frequency range of 0…500 Hz, allowing for flexible use. The output voltage matches or stays below the power supply voltage, and it is designed for secure cabinet mounting. For seamless communication, it features a 2-wire RS 485 interface for Modbus serial data transfer. Optimal performance is maintained at altitudes up to 1000 m without derating, with a current derating of 1 % per 100 m from 1000 to 4800 m. The switching frequency can be adjusted from 2...8 kHz, or 2.5...8 kHz with a derating factor, providing precise control. Capture the best deal on the Schneider 315 kW VFD with our competitive pricing and exceptional support that goes beyond the standards of other traders and suppliers.

Disclaimer: IndMALL serves solely as a platform connecting buyers and vendors. It does not participate in pricing, payment, or delivery of goods.
Buyers are advised to verify all details and deal directly with vendors before finalizing any transaction.