If you’re not fully sure about ELECTRIC-ATV340D11N4E, taking a closer look at Lenze VFD, Schneider Modicon M580 PLC and Magelis HMI Software often helps compare reliability, cost, and availability.
ATV340D11N4E - Schneider 400V 3 Phase Ethernet VSD
Technical specificatons of Schneider 400V 3 Phase Ethernet VSD ATV340D11N4E:

| Motor Power hp | 20 hp for normal duty15 hp for heavy duty |
| [Us] Rated Supply Voltage | 380...480 V - 15...10 % |
| Continuous Output Current | 32 A at 4 kHz for normal duty24 A at 4 kHz for heavy duty |
| Degree of Protection | - |
Schneider 400V 3 Phase Ethernet VSD ATV340D11N4E Technical Specifications:
| Specification | Value |
|---|---|
| Analogue input number | 22 |
| Motor power hp | 20 hp for normal duty15 hp for heavy duty |
| Protection type | Thermal protection: motorSafe torque off: motorMotor phase loss: motorThermal protection: driveSafe torque off: driveOverheating: driveOvercurrent: driveOutput overcurrent between motor phase and earth: driveOutput overcurrent between motor phases: driveShort-circuit between motor phase and earth: driveShort-circuit between motor phases: driveMotor phase loss: driveDC Bus overvoltage: driveLine supply overvoltage: driveLine supply undervoltage: driveInput supply loss: driveExceeding limit speed: driveBreak on the control circuit: drive |
| Network number of phases | 3 phases |
| Electrical connection | Control: screw terminal 0.2...2.5 mm²/AWG 24...AWG 12Line side: screw terminal 4...25 mm²/AWG 10...AWG 3DC bus: screw terminal 4...25 mm²/AWG 10...AWG 3Motor: screw terminal 2.5...25 mm²/AWG 12...AWG 3 |
| Continuous output current | 32 A at 4 kHz for normal duty24 A at 4 kHz for heavy duty |
| Overvoltage category | Class III |
| Noise level | 55.6 dB |
| Analogue output number | 1 |
| Degree of protection | - |
| Environmental class (during operation) | Class 3C3 according to IEC 60721-3-3Class 3S3 according to IEC 60721-3-3 |
| [Us] rated supply voltage | 380...480 V - 15...10 % |
| Standards | IEC 61800-3IEC 61800-5-1IEC 60721-3IEC 61508IEC 13849-1UL 618000-5-1UL 508C |
| Relay output number | 2 |
| Ambient air temperature for operation | -15…50 °C without derating (vertical position)50…60 °C with derating factor (vertical position) |
| Discrete input number | 5 |
| Product certifications | ULCSATÜVEACCTick |
| Type of cooling | Forced convection |
| Net weight | 9.5 kg |
| EMC filter | Class C3 EMC filter integrated |
| Communication port protocol | Modbus TCPEtherNet/IPModbus serial |
| Supply frequency | 50...60 Hz +/- 5 % |
| Mounting mode | Cabinet mount |
| Discrete output number | 2 |
| Connector type | 3 RJ45 |
Call us for the best rates on Schneider 400V 3 Phase Ethernet VSD ATV340D11N4E and unlock exclusive pricing. The technical attributes of the ATV340D11N4E include a motor power of 20 hp for normal duty and 15 hp for heavy duty. It offers an adjustable switching frequency range of 2...16 kHz, adjustable to 4...16 kHz with a derating factor. The continuous output current is 32 A at 4 kHz for normal duty and 24 A at 4 kHz for heavy duty, with a maximum input current of 34.7 A. The output voltage matches the <= power supply voltage for compatibility with various systems. This product is part of the Altivar Machine ATV340 range, operating on a supply frequency of 50...60 Hz +/- 5 %. For detailed specifications, refer to the ATV340D11N4E Datasheet. The sensor is designed for Cabinet mount and uses a 2-wire RS 485 physical interface, with 3 RJ45 connectors for seamless connectivity. Get the ATV340D11N4E Price and request the ATV340D11N4E Manual for more information. Trust in our ability to provide better pricing and support than other dealers.