MPS-M50TUH03E45CZZ: Sick Position Sensors with IO-Link for Pneumatic Drives
Technical Specifications of Sick Position Sensors with IO-Link for Pneumatic Drives MPS-M50TUH03E45CZZ:

| Measuring Range | 50 mm |
| Output Function | Analog, IO-Link |
| Electrical Wiring | DC 4-wire |
| Connection Type | Cable with connector M12, with knurled nuts, 0.3 m |
Sick Position Sensors with IO-Link for Pneumatic Drives MPS-M50TUH03E45CZZ Technical Specifications:
| Specification | Value |
|---|---|
| Cylinder type | T-slot |
| Detection zone | 0 mm ... 50 mm |
| Cylinder types with adapter | Profile cylinderTie rod cylinderRound body cylinderDovetail groove cylinderSMC rail CDQ2SMC rail ECDQ2 |
| Measuring range | 50 mm |
| Housing length | 32.5 mm |
| Output function | Analog, IO-Link |
| Electrical wiring | DC 4-wire |
| Analog output (voltage) | 0 V ... 10 V |
| Enclosure rating | IP67 |
| Diagnostic functionality | Actuator diagnosis |
| Supply voltage | 13 V DC ... 30 V DC |
| Min. load resistance | ≥ 10 kΩ |
| Time delay before availability | 0.15 s |
| Power consumption | ≤ 550 mW |
| Required magnetic field sensitivity, typ. | 2 mT ... 20 mT |
| Resolution, typ. | 0,01 mm |
| Linearity error, typ. | 0.3 mm |
| Repeat accuracy, typ. | 0.05 mm |
| Sampling rate, typ. | 1 ms |
| Ambient operating temperature | –20 °C ... +70 °C |
| Shock and vibration resistance | 30 g, 11 ms / 10 ... 55 Hz, 1 mm |
| Connection type | Cable with connector M12, with knurled nuts, 0.3 m |
| Conductor cross section | 0.08 mm² |
| Cable diameter | Ø 2.6 mm |
| Bending radius | For flexible use > 10 x cable diameter |
| Cable outlet | Axial |
| MaterialHousingPlastic, PA, strengthenedCablePUR | Material |
| Housing | Plastic, PA, strengthened |
| Cable | PUR |
| Communication interface | IO-Link V1.1 |
| Communication Interface detail | COM3 |
| Cycle time | 1 ms |
| Process data length | 32 Bit |
| Magnetic field strength | 2 mT ... 18 mT |
Ask for the Pricing of Sick Position Sensors with IO-Link for Pneumatic Drives MPS-M50TUH03E45CZZ at unbeatable prices. Detailed Specifications of MPS-M50TUH03E45CZZ features range of 50 mm and a compact housing length of 32.5 mm. The sensor features an Analog, IO-Link output function with, designed for precise measurements in industrial applications. It operates using a DC 4-wire electrical wiring system and provides an analog voltage output of 0 V ... 10 V. Rated IP67, the sensor is built to withstand harsh environments, ensuring reliable performance. The supply voltage ranges from 13 V DC ... 30 V DC , with a power consumption of ≤ 550 mW, making it energy-efficient. The connection type is an Cable with connector M12, with knurled nuts, 0.3 m, allowing flexible integration. The housing is made from Plastic, PA, strengthened, and the cable is made of durable PUR material. Now's the Time to Secure a Quote for your requirement of Sick Position Sensors with IO-Link for Pneumatic Drives. We're committed to offering more favorable pricing and more responsive support than other Traders.