Maintenance teams planning replacements for MPS-100CLTU0 frequently review Sick Diffuse Sensor, Sick Mzc2 1V7Ps Fu0 and Sick Incremental Sensors to prevent downtime, checking availability and compatibility with existing systems.
MPS-100CLTU0: Sick Industrial Position Sensors With C-Slot Technology
Technical Specifications of Sick Industrial Position Sensors With C-Slot Technology MPS-100CLTU0:

| Measuring range | 100 mm |
| Switching output | Push-pull: PNP/NPN |
| Electrical Wiring | DC 4-wire |
| Connection type | Cable, 4-wire, 2 m |
Sick Industrial Position Sensors With C-Slot Technology MPS-100CLTU0 Technical Specifications:
| Specification | Value |
|---|---|
| Cylinder type | C-slot |
| Cylinder types with adapter | Round body cylinderProfile cylinders and tie-rod cylindersSMC rail CDQ2SMC rail ECDQ2 |
| Measuring range | 100 mm |
| Housing length | 115 mm |
| Switching output | Push-pull: PNP/NPN |
| Output function | Analog, IO-Link, Switching output |
| Electrical wiring | DC 4-wire |
| Analog output (voltage) | 0 V ... 10 V |
| Analog output (current) | 4 mA ... 20 mA |
| Enclosure rating | IP67 |
| Teach-in control panel | Teaching in analog outputsSelecting the current/voltage outputInverting the analog outputTeaching in digital switching outputs |
| IO-Link | Teaching in 4 switching pointsPin 2 configuration (0 V–10 V, 4 mA–20 mA)Measuring range (mm) teach-in (analog output)Disabling teach-in pushbuttonTeach-in modes per output via IO-Link (cylinder switch mode, two point mode, window mode, and single point mode); ✔ |
| Supply voltage | 12 V DC ... 30 V DC |
| Power consumption | 42 mA, without load |
| Voltage drop | ≤ 2 V |
| Continuous current Ia | ≤ 100 mA |
| Max. load resistance | ≤ 500 Ω Power Output, at 24 V |
| Min. load resistance | ≥ 2 kΩ |
| Protection class | III |
| Time delay before availability | 0.15 s |
| Required magnetic field sensitivity, typ. | 3 mT ... 12 mT |
| Resolution, typ. | ≥ 50 µm |
| Linearity error, typ. | 0.3 mm |
| Repeat accuracy, typ. | 0.1 mm |
| Sampling rate, typ. | 1 ms |
| Reverse polarity protection | Yes |
| Short-circuit protection | Yes |
| Status indicator LED | Yes |
| Digital switching output | Yes |
| Teach-in | Yes |
| Ambient operating temperature | –20 °C ... +70 °C |
| Shock and vibration resistance | 30 g, 11 ms / 10 ... 55 Hz, 1 mm |
| EMC | According to EN 60947-5-7 |
| Connection type | Cable, 4-wire, 2 m |
| Deep-freeze property | Do not bend below 0 °C |
| Cable diameter | Ø 2.6 mm |
| Bending radius | With fixed installation > 5 x cable diameter |
| Cable outlet | Axial |
| MaterialHousingPlasticCablePUR | Material |
| Housing | Plastic |
| Cable | PUR |
| Communication interface | IO-Link V1.1 |
| Communication Interface detail | COM3 |
| Cycle time | 1 ms |
| Process data length | 16 Bit |
| Process data structure | Bit 0 = switching signal QL1Bit 1 = switching signal QL2Bit 2 = switching signal QL3Bit 3 = switching signal QL4Bit 4 ... 15 = position (in 50 μm) |
Get A Quote for Sick Industrial Position Sensors With C-Slot Technology MPS-100CLTU0 at the best price. Here are the brief Technical Specifications of MPS-100CLTU0 are 100 mm measuring range and a housing length of 115 mm, providing versatile Push-pull: PNP/NPN switching output. Equipped with both Analog, IO-Link, Switching output, the sensor supports and operates using a DC 4-wire electrical system. The analog output offers a voltage range of 0 V ... 10 V and a current output of 4 mA ... 20 mA, ensuring precise measurement capabilities. The sensor's supply voltage ranges from 12 V DC ... 30 V DC, with a power consumption of 42 mA, without load. The voltage drop is ≤ 2 V and the continuous current (Ia) is ≤ 100 mA , ensuring reliable performance. The connection type includes a Cable, 4-wire, 2 m for secure attachment. The housing is made of durable Plastic, and the cable is PUR. It's Time to get a Quote for your requirement of Sick Industrial Position Sensors With C-Slot Technology. We guarantee unmatched pricing and unparalleled support compared to other Distributors.