Many engineers reviewing Schneider ELECTRIC-ATS130N2D80LT also explore Lenze Drive, Schneider Modicon M580 PLC and Magelis HMI Software, ensuring they don’t miss strong alternatives before finalizing procurement decisions.
ATS130N2D80LT: Schneider 80A Altivar Soft Starter
The ATS130N2D80LT is a high-performance soft starter from Schneider Electric, part of the trusted Altivar ATS130 Soft Starter range.

| Brand | Schneider |
| Product Type | VFD(Variable Frequency Drive) |
| Product | ATS130N2D80LT |
Schneider 80A Altivar Soft Starter ATS130N2D80LT Technical Specifications:
| Specification | Value |
|---|---|
| Power supply frequency | 50...60 Hz +/- 5 Hz |
| Operating cycles/hour | 25 cyc/h |
| Maximum deflection under vibratory load (during transport) | 3 mm at 2-9 Hz |
| Maximum acceleration under vibratory load (during storage) | 10 m/s² at 9...200 Hz |
| Height | 197 mm |
| Relay output number | 1 |
| Display type | 1 LED (green) for control power energized1 LED (yellow and red) for motor operation phases, errors |
| Pollution degree | Level 2 |
| Minimum motor current | 20 % Ie |
| Protection type | Phase failure: mainsThermal protection: starterBypass error: starterControl voltage Us: starter |
| Package 1 Length | 28.000 cm |
| Maximum acceleration under vibrational stress (during operation) | 10 m/s² at 9...200 Hz |
| Environmental class (during operation) | Without salt mist: 3C3 conforming to IEC 60721-3-33S3 conforming to IEC 60721-3-3 |
| Suitable for mounting onto standard rails | TRUE |
| Overload current profile | 300 % Ie for 5 s |
| [Uimp] rated impulse withstand voltage | 4 kV |
| Function available | Deceleration voltage rampBoost |
| Minimum switching current | 2.5 mA at 24 V DC for relay outputs |
| Operating altitude | 0...1000 m without derating1000...4000 m 1 % per 100 m |
| Package 1 Weight | 2.560 kg |
| Motor power hp | 25 hp at 200 V normal duty25 hp at 208 V normal duty30 hp at 230 V normal duty60 hp at 460 V normal duty60 hp at 480 V normal duty |
| IP degree of protection | IP20 |
| Ambient air transport temperature | -40…70 °C |
| Product or component type | Soft starter |
| Utilisation category | AC-53A |
| Ue power supply voltage | 200...480 V - 15...10 % |
| Maximum switching current | On resistive load for relay outputs : 1 A 250 V AC 400000 cyclesOn resistive load for relay outputs : 1 A 30 V DC 400000 cyclesOn inductive load for relay outputs : 1 A 250 V AC cos phi = 0.4 100000 cyclesOn inductive load for relay outputs : 1 A 30 V DC cos phi = 0.4 100000 cycles |
| Depth | 180 mm |
| Operating position | Vertical +/- 30 degree |
| [Ui] rated insulation voltage | 480 V |
| Network number of phases | 3 phases |
| Input compatibility | Discrete input level 1 PLC conforming to EN/IEC 61131-2 |
| Device connection | In line |
| Width | 81 mm |
| Torque control | FALSE |
| Ambient air temperature for storage | -25…70 °C |
| Control power | 21.6 W starting and stopping3 W steady state |
| Range of product | Altivar Soft Starter ATS130 |
| [Uc] control circuit voltage | 24 V DC |
| Relative humidity | 5…95 % non condensing without dripping water conforming to IEC 60068-2-3 |
| Power loss per device current dependent | 16 W |
| Net weight | 2.3 kg |
| [Ie] rated operational current | 80 A in line (at <40 °C) |
| Maximum deflection under vibratory load (during storage) | 3 mm at 2-9 Hz |
| Ambient air temperature for operation | -10…40 °C (without derating)40…60 °C (with current derating of 2 % per °C) |
| Motor power kW | 22 kW at 230 V normal duty45 kW at 400 V normal duty45 kW at 440 V normal duty |
| Power loss static current independent | 3 W |
| Power loss during starting | 512 W 300 % Ie |
| Relay output type | Relay outputs R1A, R1C NO |
| Number of Units in Package 1 | 1 |
The Schneider ATS130N2D80LT soft starter offers a rated operational current of 80 A and supports 25 cycles/hour. It delivers smooth control of motors rated up to 60 hp at 480 V or 45 kW at 400 V. Designed for in-line connection, it features overload handling of 300% Ie for 5 seconds and operates at 50–60 Hz ±5% input frequency.
The device comes with LED indicators for control status and fault diagnosis, and includes multiple protection types: phase failure, thermal protection, bypass error, and control voltage issues. Its rugged build allows vertical installation ±30°, with a temperature range of -10°C to 60°C (with derating above 40°C). The Uc control voltage is 24 V DC, and it includes relay output R1A/R1C NO.
With dimensions of 197 mm (H) × 81 mm (W) × 180 mm (D) and a net weight of 2.3 kg, this unit is DIN-rail compatible and IP20 rated. It supports up to 4000 m altitude operation with derating, meets IEC 60721-3-3 (3C3, 3S3) standards, and includes features like boost and deceleration voltage ramp for flexible motor control. Power losses are 512 W during startup and 3 W static.
The Schneider 80A Altivar Soft Starter ATS130N2D80LT is ideal for industrial motors driving compressors, blowers, mixers, and pumps. Its precise control and high overload handling make it suitable for systems requiring low mechanical stress during startup. This helps prolong equipment life and reduces energy surges.
Engineers rely on the ATS130N2D80LT for its operational stability, compact design, and compliance with industrial automation standards. Whether in manufacturing, HVAC, or water treatment facilities, it provides exceptional motor startup performance with minimal vibration impact.
Need a reliable 80A soft starter? Choose IndMALL to get the best price and priority support for the Schneider ATS130N2D80LT. We connect you with verified vendors and ensure timely delivery for your industrial automation needs.