Many procurement teams check ELECTRIC-ATV610D22N4 against Lenze Drive, Schneider Modicon M580 PLC and Magelis HMI Software before signing purchase orders, verifying quality, compliance, and after-sales support availability.
Schneider ATV610D22N4 Variable Speed Drive
The Schneider ATV610D22N4 is a high-performance variable speed drive (VSD) designed for 3-phase motor applications.

| Brand | Schneider |
| Product Type | VFD - Variable Frequency Drive |
| Model Number | ATV610D22N4 |
Schneider ATV610D22N4 Variable Speed Drive – Technical Specifications
| Specification | Value |
|---|---|
| Mounting mode | Cabinet mount |
| Height | 495 mm580 mm with EMC plate |
| Analogue input type | AI1, AI2, AI3 software-configurable voltage: 0...10 V DC, impedance: 30 kOhm, resolution 12 bitsAI1, AI2, AI3 software-configurable current: 0...20 mA, impedance: 250 Ohm, resolution 12 bitsAI2, AI3 software-configurable temperature probe or water level sensor |
| Relative humidity | 5…95 % without condensation conforming to IEC 60068-2-3 |
| Range of product | Easy Altivar 610 |
| Ambient air temperature for operation | -15…45 °C (without derating)45…60 °C (with derating factor) |
| Communication port protocol | Modbus serial |
| Operating position | Vertical +/- 10 degree |
| Linearity error | AI1, AI2, AI3: +/- 0.15 % of maximum value for analog inputAQ1, AQ2: +/- 0.2 % for analog output |
| Product destination | Asynchronous motorsSynchronous motors |
| IP degree of protection | IP20 |
| number of preset speeds | 16 preset speeds |
| Line current | 41.9 A at 380 V (normal duty)36.2 A at 460 V (normal duty)36 A at 380 V (heavy duty)31.6 A at 460 V (heavy duty) |
| Braking to standstill | By DC injection |
| Number of Units in Package 2 | 4 |
| Analogue input number | 3 |
| Output voltage | <= power supply voltage |
| Analogue output type | Software-configurable current AQ1, AQ2: 0...20 mA, resolution 10 bitsSoftware-configurable voltage AQ1, AQ2: 0...10 V DC impedance 470 Ohm, resolution 10 bits |
| Refresh time | Relay output (R1, R2, R3): 5 ms (+/- 0.5 ms) |
| Sampling duration | 5 ms +/- 0.1 ms (AI1, AI2, AI3) - analog input2 ms +/- 0.5 ms (DI1...DI6)configurable - discrete input5 ms +/- 1 ms (DI5, DI6)configurable - pulse input10 ms +/- 1 ms (AQ1, AQ2) - analog output |
| Depth | 232 mm |
| Acceleration and deceleration ramps | S, U or customizedLinear adjustable separately from 0.01 to 9000 s |
| Product specific application | Fan, pump, compressor, conveyor |
| Continuous output current | 46.3 A at 4 kHz for normal duty39.2 A at 4 kHz for heavy duty |
| Apparent power | 28.8 kVA at 460 V (normal duty)25.2 kVA at 460 V (heavy duty) |
| Product or component type | Variable speed drive |
| Width | 211 mm |
| Supply | External supply for digital inputs: 24 V DC (19…30 V), <1.25 mA, protection type: overload and short-circuit protectionInternal supply for reference potentiometer (1 to 10 kOhm): 10.5 V DC +/- 5 %, <10 mA, protection type: overload and short-circuit protection |
| Maximum transient current | 50.9 A during 60 s (normal duty)58.8 A during 60 s (heavy duty) |
| Physical interface | 2-wire RS 485 for Modbus serial |
| EMC filter | Integrated conforming to IEC 61800-3 category C3 with 50 m |
| Discrete input type | DI1...DI6 programmable as logic input, 24 V DC (<= 30 V), impedance: 3.5 kOhmDI5, DI6 programmable as pulse input: 0…30 kHz, 24 V DC (<= 30 V) |
| Accuracy | +/- 0.6 % AI1, AI2, AI3 for a temperature variation 60 °C analog input+/- 1 % AQ1, AQ2 for a temperature variation 60 °C analog output |
| Ambient air temperature for storage | -40…70 °C |
| Noise level | 65 dB conforming to 86/188/EEC |
| Relay output number | 3 |
| Discrete input logic | Positive logic (source): DI1...DI6 configurable logic input, < 5 V (state 0), > 11 V (state 1)Negative logic (sink): DI1...DI6 configurable logic input, > 16 V (state 0), < 10 V (state 1)Positive logic (source): DI5, DI6 configurable pulse input, < 0.6 V (state 0), > 2.5 V (state 1) |
| Connector type | 1 RJ45 (on the remote graphic terminal) for Modbus serial |
| Relay Output Type | Configurable relay logic R1: fault relay NO/NC electrical durability 100000 cyclesConfigurable relay logic R2: sequence relay NO electrical durability 100000 cyclesConfigurable relay logic R3: sequence relay NO electrical durability 100000 cycles |
| Net Weight | 13.5 kg |
| Motor power hp | 30 hp for normal duty25 hp for heavy duty |
| Electrical connection | Control, screw terminals: 0.5...1.5 mm²Line side, screw terminal: 16 mm²Motor, screw terminal: 16 mm² |
| Transmission frame | RTU for Modbus serial |
| Maximum switching current | Relay output R1, R2, R3 on resistive load, cos phi = 1: 3 A at 250 V ACRelay output R1, R2, R3 on resistive load, cos phi = 1: 3 A at 30 V DCRelay output R1, R2, R3 on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 250 V ACRelay output R1, R2, R3 on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 30 V DC |
| Pollution degree | 2 conforming to IEC 61800-5-1 |
| Analogue output number | 2 |
| Switching frequency | 2...12 kHz adjustable |
| Motor power kW | 22 kW for normal duty18.5 kW for heavy duty |
| Supply frequency | 50...60 Hz +/-5 % |
| Output frequency | 0.1…500 Hz |
| Protection type | Thermal protection: motorMotor phase break: motorThermal protection: driveOverheating: driveOvercurrent between output phases and earth: driveOverload of output voltage: driveShort-circuit protection: driveMotor phase break: driveOvervoltages on the DC bus: driveLine supply overvoltage: driveLine supply undervoltage: driveLine supply phase loss: driveOverspeed: driveBreak on the control circuit: drive |
| Type of cooling | Forced convection |
ATV610D22N4 by Schneider is an industrial VFD (Variable Frequency Drive) from the Altivar 610 range, engineered for precise speed/torque control in pumps, fans, compressors, and conveyors—purpose-built for OEM panels and plant upgrades.
ATV610D22N4 delivers 22 kW (30 HP) in normal duty and 18.5 kW (25 HP) in heavy duty, with continuous output currents of 46.3 A @ 4 kHz (ND) and 39.2 A @ 4 kHz (HD), plus transient capability up to 50.9 A (ND) and 58.8 A (HD) for 60 s. Cabinet-mount size is H 495 mm (580 mm with EMC plate) × W 211 mm × D 232 mm, IP20, 13.5 kg. Three software-configurable analog inputs accept 0–10 V or 0–20 mA (12-bit), two analog outputs provide 0–10 V/0–20 mA (10-bit), and six digital inputs (incl. pulse) enable granular control; three relay outputs (5 ms refresh) support permissives/alarms. Control connectivity is native Modbus RTU on RS-485 via RJ45. The drive offers 0.1–500 Hz output frequency, 2–12 kHz switching, and independent accel/decel ramps from 0.01–9000 s for smooth starts/stops. It operates from -15…45 °C (no derate) up to 60 °C (with derate) and 5–95% RH (IEC 60068-2-3), integrates an EMC filter (IEC 61800-3 C3), and protects against over/undervoltage, short-circuit, motor thermal, phase loss, overspeed—practical reasons engineers trust this Schneider Altivar 610 VFD in harsh environments.
In the field, ATV610D22N4 stabilizes pressure and cuts kWh in pump skids (DC-injection braking helps reduce water hammer), modulates airflow in HVAC fans to lower noise and demand charges, and keeps product flow steady on conveyors using S/U/linear ramps to protect belts and gearboxes. For compressors, speed trims match air demand to reduce heat and maintenance. Panel teams also benefit from straightforward screw terminals (16 mm² on line/motor), an internal 10.5 V reference for potentiometers, and a 24 V DC supply for digital inputs—details that shorten commissioning time and improve uptime.
For documentation and procurement, refer to the official ATV610D22N4 datasheet and ATV610D22N4 manual, and request the latest ATV610D22N4 price from verified partners. This page builds topical authority around Schneider Altivar 610 VFD, atv610d22n4, and atv610d22n4 schneider with spec-accurate, application-ready guidance—choose ATV610D22N4.