The Reer MOSAIC MO2 Safety Controller offers PL e safety level, safety input, Removable terminal blocks. screw contacts connections. Manufactured by Reer Safety under the Reer Safety Controller category, this model belongs to the MOSAIC Series.

| Brand | Reer Safety |
| Product Type | Safety Controller |
| Model Number | MOSAIC MO2 |
Reer MOSAIC MO2 Safety Controller โ Technical Specifications
| Specification | Value |
|---|---|
| Safety level | PL e |
| Safety level (SIL / PL) | SIL 3 - SILCL 3 - PL e - Cat. 4 |
| Operating temperature (ยฐC) | - 10 ... 55 |
| Signalling | LEDs indication for operating status and fault diagnosis. LED indication of the: OSSD outputs. reset request and status outputs condition |
| Safety output type | 2 OSSD PNP (400 mA at 24 VDC) with protection against short circuit. overload and reverse polarity |
| Connections | Removable terminal blocks. screw contacts |
| MTTFD (ISO13849) years | 30 ... 100 |
| PFHD (IEC 61508) | 4.09E-09 |
| Safety outputs | 2 OSSD pairs (400 mA) |
| Status outputs | 2 PNP (100 mA) |
| Storage temperature (ยฐC) | -20 ... +85 |
| MSC connector provided | Yes |
| Connection with MSC BUS | Yes |
| Start/Restart inputs and EDM | 2 |
| Packaging dimensions HxLxW (mm) | 36 x 127 x 113 |
| Product class | C |
| Custom tariff | 85371091 |
| Power supply (VDC) | 24 ยฑ 20% |
| Dimensions HxWxD (mm) | 108 x 22.5 x 114.5 |
| Degree of protection | IP20 for housing - IP2X for terminal block |
| Fastening | 35 mm DIN rail fastening according to EN 50022-35 standard |
| Gross weight (g) | 170.4 |
Obtain a Quote for Reer SIL 3 Safety Controllers MOSAIC MO2 part no: 1100030 at economical prices. Specifications Overview for MOSAIC MO2, 1100030 reveals provide top-tier protection with PL e safety level, featuring , SIL 3 - SILCL 3 - PL e - Cat. 4 certification. Operating efficiently between - 10 ... 55, these controllers offer clear LEDs indication for operating status and fault diagnosis. LED indication of the: OSSD outputs. reset request and status outputs condition. Equipped with 2 OSSD PNP (400 mA at 24 VDC) with protection against short circuit. overload and reverse polarity, they ensure reliable safety outputs. The Removable terminal blocks. screw contacts, coupled 2 OSSD pairs (400 mA) and test outputs, add to their robustness. These controllers are IP20 for housing - IP2X for terminal blockprotected enclosures, designed for 35 mm DIN rail fastening according to EN 50022-35 standard. With a compact design of 108 x 22.5 x 114.5 and a gross weight of 170.4 g, they offer reliable performance for industrial applications. Take the First Step with a Quote for your requirement of Reer SIL 3 Safety Controllers. Our commitment to better pricing and exceptional support sets us apart from other Competitors.