Reer MOSAIC M1SC Safety Controller

The Reer MOSAIC M1SC Safety Controller offers PL e safety level, 8 digital inputs safety input, Removable terminal blocks. clamp contacts connections. Manufactured by Reer Safety under the Reer Safety Controller category, this model belongs to the MOSAIC Series.

BrandReer Safety
Product TypeSafety Controller
Model NumberMOSAIC M1SC

Reer MOSAIC M1SC Safety Controller โ€“ Technical Specifications

SpecificationValue
Safety levelPL e
Safety inputs8 digital inputs
Safety level (SIL / PL)SIL 3 - SILCL 3 - PL e - Cat. 4
Operating temperature (ยฐC)- 10 ... 55
SignallingLEDs indication for operating status and fault diagnosis. LED indication of the: inputs. OSSD outputs. reset request and status outputs condition
Safety output type4 single OSSD. or 2 pairs (PNP - 400mA at 24 VDC) with protection against short circuit. overload and reverse polarity
ConnectionsRemovable terminal blocks. clamp contacts
MTTFD (ISO13849) years30 ... 100
PFHD (IEC 61508)1.34E-08
Safety outputs4 single OSSD. or 2 pairs (400 mA)
Status outputs4 PNP (100 mA)
Test outputs4
Storage temperature (ยฐC)-20 ... +85
MSC connector providedNo
Connection with MSC BUSYes
Start/Restart inputs and EDM4
Housing for MCMYes
USB inputYes
Packaging dimensions HxLxW (mm)36 x 127 x 113
Product classC
Custom tariff85371091
Power supply (VDC)24 ยฑ 20%
Dimensions HxWxD (mm)108 x 22.5 x 114.5
Degree of protectionIP20 for housing - IP2X for terminal block
Fastening35 mm DIN rail fastening according to EN 50022-35 standard
Gross weight (g)206.8
Obtain a Quote for Reer 4 Test Output Safety Controllers MOSAIC M1SC part no: 1100004 at economical prices. Specifications Overview for MOSAIC M1SC, 1100004 reveals provide top-tier protection with PL e safety level, featuring 8 digital inputs, SIL 3 - SILCL 3 - PL e - Cat. 4 certification. Operating efficiently between - 10 ... 55, these controllers offer clear LEDs indication for operating status and fault diagnosis. LED indication of the: inputs. OSSD outputs. reset request and status outputs condition. Equipped with 4 single OSSD. or 2 pairs (PNP - 400mA at 24 VDC) with protection against short circuit. overload and reverse polarity, they ensure reliable safety outputs. The Removable terminal blocks. clamp contacts, coupled 4 single OSSD. or 2 pairs (400 mA) and 4 test outputs, add to their robustness. These controllers are IP20 for housing - IP2X for terminal blockprotected enclosures, designed for 35 mm DIN rail fastening according to EN 50022-35 standard. With a compact design of 108 x 22.5 x 114.5 and a gross weight of 206.8 g, they offer reliable performance for industrial applications. Take the First Step with a Quote for your requirement of Reer 4 Test Output Safety Controllers. Our commitment to better pricing and exceptional support sets us apart from other Competitors.