During technical comparisons, SR-E4-C appears alongside Sick Safety Relay, Reer Safety Sv Mr0 and Omron Safety Relay Suppliers In Bhiwadi so engineers assess signal types, ingress protection, and ambient tolerances accurately.
Reer SR E4 C Safety Light Curtain
The Reer SR E4 C Safety Light Curtain offers PL e safety level, 2 NO (6A at 250 VAC) safety relay outputs, Removable terminal blocks. clamp contacts. Manufactured by Reer Safety under the Reer Safety Light Curtain category, this model belongs to the SR Series.

| Brand | Reer Safety |
| Product Type | Safety Interface |
| Model Number | SR E4 C |
Reer SR E4 C Safety Light Curtain – Technical Specifications
| Specification | Value |
|---|---|
| Safety level | PL e |
| Safety level (SIL / PL) | PL e - Cat. 4 |
| Operating temperature (°C) | -30 ... 55 |
| Response time (ms) | ≤ 20 |
| Signalling | LEDs indication for status and diagnostic: power supply. channel 1 and channel 2 |
| Connections | Removable terminal blocks. clamp contacts |
| MTTFD (ISO13849) years | The values depend on the type of use. Refer to the technical manual |
| PFHD (IEC 61508) | The values depend on the type of use. Refer to the technical manual |
| Safety devices to be connected | Emergency stop buttons and safety switches |
| Safety relay outputs | 2 NO (6A at 250 VAC) |
| Product class | C |
| Power supply (VDC) | 24 ± 20% |
| Dimensions HxWxD (mm) | 99 x 22.5 x 114.5 |
| Degree of protection | IP2X |
| Fastening | 35 mm DIN rail fastening according to EN 50022-35 standard |
| Start/Restart | Automatic/Manual |
| Min. switching current at 24 VDC (mA) | 6 |
Mail Us for Reer Automatic Start/Restart Safety Relays SR E4 C part no: 1330808 at the lowest pricing. Technical Specs Summary of SR E4 C, 1330808 are These interfaces meet PL e - Cat. 4 standards, ensuring top-tier protection. Operating in temperatures from -30 ... 55, they feature a response time of ≤ 20. The interfaces include LEDs indication for status and diagnostic: power supply. channel 1 and channel 2 and use Removable terminal blocks. clamp contacts. They are compatible with Emergency stop buttons and safety switches The safety relay outputs are configured as 2 NO (6A at 250 VAC). Designed for reliability, the interfaces are mounted on a 35 mm DIN rail fastening according to EN 50022-35 standard. With dimensions of 99 x 22.5 x 114.5, they operate at 24 ± 20% and offer IP2X protection. Navigate Your Needs with a Quote for your requirement of Reer Automatic Start/Restart Safety Relays. We excel in offering more cost-effective and supportive solutions than other Competitors.