Many engineers reviewing Sick RLY3-TIME100 also explore Sick Diffuse Sensor, Sick Rly3 Ossd100 and Sick Safety Relay, ensuring they donβt miss strong alternatives before finalizing procurement decisions.
Sick RLY3-TIME100 Safety Relay
RLY3-TIME100 1100688 Sick Safety Control Relay Technical Specifications

| Brand | Sick |
| Product Type | Safety Relay |
| Product | RLY3-TIME100 |
Sick RLY3-TIME100 Safety Relay β Technical Specifications
| Specification | Value |
|---|---|
| Compatible sensor types | Safety sensors with OSSDs, Safety sensors with potential-free outputs |
| Safety integrity level | SIL 3 (IEC 61508) |
| Category | Category 4 (ISO 13849-1) |
| Performance level | PL e (ISO 13849-1) |
| TM (mission time) | 20 years (ISO 13849-1) |
| Sensor monitoring | Discrepancy monitoring, Sequence monitoring, Cross-circuit detection |
| Restart interlock | β |
| Reset | Automatic, Manual |
| External device monitoring (EDM) | β |
| Connection type | Front connector with spring terminals |
| Inputs | 2 safety inputs,1 input for reset pushbutton or external device monitoring (EDM) |
| Outputs | 2 enabling current paths (safe), 1 release-delayed enabling current path, for stop category 1 applications (safe), 2 application diagnostic outputs (not safe), 3 test pulse outputs (not safe) |
| Display elements | LEDs |
| Configuration method | Hard wired, DIP switch |
| Supply voltage VS | 24 V DC (16.8 V ... 30 V) |
| Residual ripple | β€ 2.4 V |
| Power consumption | β€ 2.5 W (DC) |
| Input voltage HIGH | 24 V DC (11 V ... 30 V) |
| Input voltage LOW | 0 V DC (β3 V ... 5 V) |
| Input current | 4 mA ... 6 mA |
| Test pulse width | β€ 1 ms |
| Test pulse rate | β€ 10 Hz |
| Response time | 12 ms |
| Type of output | N/O contacts, positively guided |
| Contact material | Silver alloy, gold flashed |
| Switching voltage | 10 V AC ... 230 V AC, 10 V DC ... 230 V DC |
| Switching current | 10 mA ... 6 A |
| Total current | 12 A |
| Overvoltage category | III (EN 60664-1) |
| Rated impulse withstand voltage Uimp | 6 kV (EN 60664-1) |
| Output voltage HIGH | β₯ Vs β 3 V |
| Output voltage LOW | β€ 3 V |
| Input current (NPN) | β€ 15 mA |
| Output current (PNP) | β€ 120 mA |
| Output voltage | β₯ Vs β 3 V |
| Test pulse interval | 40 ms |
| Dimensions (W x H x D) | 18 mm x 124.6 mm x 85.5 mm |
| Enclosure rating | IP20 (IEC 60529) |
| Ambient operating temperature | β25 Β°C ... +55 Β°C |
| Storage temperature | β25 Β°C ... +70 Β°C |
| Air humidity | β€ 95 %, Non-condensing |
| Interference emission | According to IEC 61000-6-4 |
| Interference resistance | According to IEC 61326-3-1, According to IEC 61000-6-2, According to IEC 60947-5-1 |
| Weight | 160 g |
Ask for the Pricing of Sick Safety Control Relay RLY3-TIME100 part no: 1100688 at unbeatable prices. Detailed Specifications of RLY3-TIME100, 1100688 features Safety sensors with OSSDs, Safety sensors with potential-free outputs and meets SIL 3 (IEC 61508), Category 4 (ISO 13849-1) and PL e (ISO 13849-1) standards with a 20 years (ISO 13849-1) mission time. It features Discrepancy monitoring, Sequence monitoring, Cross-circuit detection, Automatic, Manual reset. The relay has a Front connector with spring terminals, 2 safety inputs,1 input for reset pushbutton or external device monitoring (EDM). Outputs include 2 enabling current paths (safe), 1 release-delayed enabling current path, for stop category 1 applications (safe), 2 application diagnostic outputs (not safe), 3 test pulse outputs (not safe) and LEDs for display elements and is configured through a Hard wired, DIP switch method. It supports 24 V DC (16.8 V ... 30 V) supply voltage, β€ 2.4 V residual ripple, and β€ 2.5 W (DC) power consumption. The relay operates with input voltage high at 24 V DC (11 V ... 30 V) and low at 0 V DC (β3 V ... 5 V), with an input current of 4 mA ... 6 mA . The test pulse width is β€ 1 ms, and the test pulse rate is β€ 10 Hz, with a response time of 12 ms.
The relay has N/O contacts, positively guided, Silver alloy, gold flashed supporting 10 V AC ... 230 V AC, 10 V DC ... 230 V DC switching voltage, and 10 mA ... 6 A switching current and a total current of 12 A. Output voltage HIGH is β₯ Vs β 3 V, and output voltage LOW is β€ 3 V. The input current (NPN) is β€ 15 mA, and the output current (PNP) is β€ 120 mA, with an output voltage of β₯ Vs β 3 V and a test pulse interval of 40 ms. The dimensions of 18 mm x 124.6 mm x 85.5 mm and an IP20 (IEC 60529) enclosure rating. It operates in ambient temperatures of β25 Β°C ... +55 Β°C and storage temperatures of β25 Β°C ... +70 Β°C, with air humidity of β€ 95 %, Non-condensing. Now's the Time to Secure a Quote for your requirement of Sick Safety Control Relay. We're committed to offering more favorable pricing and more responsive support than other Traders.