Maintenance teams planning replacements for H7ET-NV frequently review Omron SMPS 24V 10A, Omron H7Ec N and Omron Photoelectric Sensors E3T Series to prevent downtime, checking availability and compatibility with existing systems.
Omron H7ET-NV Counter
The Omron H7ET-NV Counter is a precise time counter built for DC voltage input applications requiring stable long-duration measurement. It supports timing ranges up to 999999.9 hours or 3999 days 23.9 hours, ensuring dependable tracking. The 7-digit LCD with 8.6 mm characters offers excellent clarity, while its 20 ms reset capability ensures responsive operation. Designed for voltage input from 4.5 to 30 VDC, it integrates easily into automation systems. With IP66 front protection, strong EMC immunity, and durable shock/vibration resistance, it performs reliably. Manufactured by Omron and listed under Omron Counter products, this model is part of the H7ET-N Series.
| Brand | Omron |
| Product Type | Counters |
| Model Number | H7ET-NV |
Omron H7ET-NV Counter - Technical Specifications
| Specification | Value |
|---|---|
| Function | Time Counter |
| Time counter ranges | Increment (UP) |
| Counter Time ranges | 0.0 h to 999999.9 h/0.0 h to 3999 d 23.9 h (selectable) |
| Time counter Set value read selector | Β±100 ppm (25 β) |
| Time counter Reset system | External and manual reset |
| Input signal | Count input, Reset |
| Input method | Voltage input |
| No-voltage input (No-contact inputοΌ/ Voltage input | Hight level: 4.5 to 30 VDC Low level: 0 to 2 VDC (Input resistance Approx. 4.7 kΞ©) |
| External/Manual Reset time | 20 ms |
| Display method | LCD |
| Display Digits | 7 digit |
| Display Character height | 8.6 mm (Black) |
| Display Zero suppression | Equipped |
| Ambient temperature (Operating) | -10 to 55 β (with no freezing or condensation) |
| Ambient temperature (Storage) | -25 to 65 β (with no freezing or condensation) |
| Ambient humidity (Operating) | 25 to 85 % |
| Insulation resistance | Between current carrying terminals and exposed non-current carrying metal parts: 100 MΞ© min. (at 500 VDC) |
| Dielectric withstand voltage | Between current carrying terminals and exposed non-current carrying metal parts: 1000 VAC 50/60 Hz 1 min |
| Impulse withstand voltage | Between current carrying terminals and exposed non-current carrying metal parts: 4.5 kV |
| Noise immunity | Between reset terminals: Β±600 V Between timer input terminals: Β±600 V square-wave noise by noise simulator (pulse width: 100 ns/1 Β΅s, 1-ns rise) |
| Static immunity | Β±8 kV (malfunction) |
| Vibration resistance | Destruction: 10 to 55 Hz, 0.375 mm single amplitude each in 3 directions for 2 h Malfunction: 10 to 55 Hz, 0.15 mm single amplitude each in 3 directions for 10 min |
| Shock resistance | Destruction: 300 m/s2, 3 times each in 6 directions Malfunction: 200 m/s2, 3 times each in 6 directions |
| Degree of protection | Case front: IP66, NEMA 4 (indoors), and UL Type 4X (indoors) |
| External connection method | Screw terminal |
| Case color | Light gray (Munsell 5Y7/1) |
| Weight | Approx. 60 g |