The Schneider ATV6A0C50Q4 Variable Speed Drive offers a 500.0 kW at 400 V normal duty400.0 kW at 400 V heavy duty motor power, 2-wire RS 485 for Modbus serial, 3 phases. Manufactured by Schneider under the Schneider Variable Speed Drive (VSD) category, this model belongs to the ATV600 Series.

BrandSchneider
Product TypeVFD(Variable Frequency Drive)
ProductATV6A0C50Q4

Schneider ATV6A0C50Q4 Variable Speed Drive – Technical Specifications

SpecificationValue
Degree of protection-
Supply frequency50...60 Hz - 5...5 %
Vibration resistance1.5 mm peak to peak (f= 2…13 Hz) conforming to IEC 60068-2-60.5 gn (f= 13…200 Hz) conforming to IEC 60068-2-6
IP degree of protectionIP00 (for IP21 or IP54 cabinet integration) conforming to IEC 61800-5-1IP00 (for IP21 or IP54 cabinet integration) conforming to IEC 60529
Speed drive output frequency0…500 Hz
Electromagnetic compatibilityElectrostatic discharge immunity test level 3 conforming to IEC 61000-4-2Radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-41.2/50 µs - 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5Conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6
Product or component typeVariable speed drive
Output voltage<= power supply voltage
Asynchronous motor control profileConstant torque standardVariable torque standardOptimized torque mode
Mounting modeCabinet mount
Ambient air temperature for storage-40…70 °C
Continuous output current900.0 A at 2.5 kHz normal duty730.0 A at 2.5 kHz heavy duty
Relay output typeConfigurable relay logic R1: fault relay NO/NC electrical durability 100000 cyclesConfigurable relay logic R2: sequence relay NO electrical durability 100000 cyclesConfigurable relay logic R3: sequence relay NO electrical durability 100000 cycles
Minimum switching currentRelay output R1, R2, R3: 5 mA at 24 V DC
Electrical connectionControl: removable screw terminals 0.5...1.5 mm²/AWG 20...AWG 16Line side: screw terminalMotor: M10 x 2 bars
Synchronous motor control profilePermanent magnet motor
Physical interface2-wire RS 485 for Modbus serial
Pollution degree2 conforming to IEC 61800-5-1
Type of polarizationNo impedance for Modbus serial
Product destinationSynchronous motorsAsynchronous motors
Number of preset speeds16 preset speeds
Operating altitude<= 1000 m without derating1000...4800 m with current derating 1 % per 100 m
Apparent power586 kVA at 400 V normal duty472 kVA at 400 V heavy duty
[Us] rated supply voltage400 V - 15...10 %
Ambient air temperature for operation-10…40 °C without derating40…50 °C with derating factor
SupplyExternal supply for digital inputs: 24 V DC (19…30 V), <1.25 mA, protection type: overload and short-circuit protectionInternal supply for reference potentiometer (1 to 10 kOhm): 10.5 V DC +/- 5 %, <10 mA, protection type: overload and short-circuit protectionInternal supply for digital inputs and STO: 24 V DC (21…27 V), <200 mA, protection type: overload and short-circuit protection
Switching frequency2.5...8 kHz with derating factor2...8 kHz adjustable
Motor power kW500.0 kW at 400 V normal duty400.0 kW at 400 V heavy duty
EMC filterIntegrated with 300 m conforming to IEC 61800-3 category C3
Communication port protocolEthernetModbus serialModbus TCP
Analogue input typeAI1, AI2, AI3 software-configurable voltage: 0...10 V DC, impedance: 30 kOhm, resolution 12 bitsAI1, AI2, AI3 software-configurable current: 0...20 mA/4...20 mA, impedance: 250 Ohm, resolution 12 bits
Maximum switching currentRelay output R1, R2, R3 on resistive load, cos phi = 1: 3 A at 250 V ACRelay output R1, R2, R3 on resistive load, cos phi = 1: 3 A at 30 V DCRelay output R1, R2, R3 on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 250 V ACRelay output R1, R2, R3 on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 30 V DC
Range of productAltivar Process ATV600
Shock resistance7 gn for 11 ms conforming to IEC 60068-2-27
Power dissipation in WForced convection: 14970 W, switching frequency 2.5 kHz (normal duty)Forced convection: 10350 W, switching frequency 2.5 kHz (heavy duty)
Nominal switching frequency2.5 kHz
Motor power hp-
Network number of phases3 phases
Send Your Inquiry for Schneider Single 400 V Altivar Modular Drives ATV6A0C50Q4 with cost-effective solutions. Essential Technical Specs of ATV6A0C50Q4 are Altivar Process ATV600 range, with top-notch specifications. The supply frequency is 50...60 Hz - 5...5 %, while the speed drive output frequency ranges from 0…500 Hz, ensuring flexibility in applications. The output voltage is equal to or less than the <= power supply voltage, and the sensor is designed for Cabinet mount. It features a 2-wire RS 485 for Modbus serial physical interface communication, supporting efficient data transfer. The sensor operates at altitudes below <= 1000 m without derating1000...4800 m with current derating 1 % per 100 m. The switching frequency is adjustable between 2.5...8 kHz with derating factor2...8 kHz adjustable, providing precise control. Capture the Best Deal with a Quote for your requirement of Schneider Single 400 V Altivar Modular Drives. Our pricing and support are designed to exceed the standards of other Traders & Suppliers.