ATV212HU22N4: Schneider Altivar 212 2.2kW 3 Phase Drive
Technical Specifications of Schneider Altivar 212 2.2kW 3 Phase Drive ATV212HU22N4:
Spec | Value |
---|---|
Connector Type | 1 open style1 RJ45 |
Motor power range AC-3 | 2.2…3 kW at 380…440 V 3 phases2.2…3 kW at 480…500 V 3 phases |
Switching Frequency | 6...16 kHz adjustable12...16 kHz with derating factor |
Power Consumption in W | 103 W |
Schneider Altivar 212 2.2kW 3 Phase Drive ATV212HU22N4 Technical Specifications:
Specification | Value |
---|---|
Connector Type | 1 open style1 RJ45 |
Minimum switching current | 3 mA at 24 V DC for configurable relay logic |
Motor power range AC-3 | 2.2…3 kW at 380…440 V 3 phases2.2…3 kW at 480…500 V 3 phases |
Net weight | 2 kg |
Switching frequency | 6...16 kHz adjustable12...16 kHz with derating factor |
Output voltage | <= power supply voltage |
Supply voltage limits | 323…528 V |
Operating position | Vertical +/- 10 degree |
Discrete input type | F programmable 24 V DC, with level 1 PLC, impedance: 4700 OhmR programmable 24 V DC, with level 1 PLC, impedance: 4700 OhmRES programmable 24 V DC, with level 1 PLC, impedance: 4700 Ohm |
Speed range | 1…10 |
[Us] rated supply voltage | 380...480 V - 15...10 % |
Supply frequency | 50...60 Hz - 5...5 % |
IP degree of protection | IP20 on upper part without blanking plate on cover conforming to IEC 61800-5-1IP20 on upper part without blanking plate on cover conforming to IEC 60529IP21 conforming to IEC 61800-5-1IP21 conforming to IEC 60529IP41 on upper part conforming to IEC 61800-5-1IP41 on upper part conforming to IEC 60529 |
Power dissipation in W | 103 W |
Network frequency | 47.5...63 Hz |
Electrical connection | VIA, VIB, FM, FLA, FLB, FLC, RY, RC, F, R, RES: terminal 2.5 mm² / AWG 14L1/R, L2/S, L3/T: terminal 6 mm² / AWG 10 |
EMC filter | Class C2 EMC filter integrated |
Motor starter type | Variable speed drive |
Depth | 150 mm |
Range of product | Altivar 212 |
Nominal switching frequency | 12 kHz |
Discrete output type | Configurable relay logic: (FLA, FLC) NO - 100000 cyclesConfigurable relay logic: (FLB, FLC) NC - 100000 cyclesConfigurable relay logic: (RY, RC) NO - 100000 cycles |
Acceleration and deceleration ramps | Automatic based on the loadLinear adjustable separately from 0.01 to 3200 s |
Warranty | 18 months |
Insulation resistance | >= 1 mOhm 500 V DC for 1 minute |
Frequency resolution | Display unit: 0.1 HzAnalog input: 0.024/50 Hz |
Tightening torque | 1.3 N.m, 11.5 lb.in (L1/R, L2/S, L3/T)0.6 N.m (VIA, VIB, FM, FLA, FLB, FLC, RY, RC, F, R, RES) |
Transmission rate | 9600 bps or 19200 bps |
Assembly style | With heat sink |
Motor power hp | 3 hp |
Dielectric strength | 3535 V DC between earth and power terminals5092 V DC between control and power terminals |
Regulation loop | Adjustable PI regulator |
Speed drive output frequency | 0.5…200 Hz |
Analogue output type | FM switch-configurable voltage 0...10 V DC, impedance: 7620 Ohm, resolution 10 bitsFM switch-configurable current 0...20 mA, impedance: 970 Ohm, resolution 10 bits |
Analogue input type | VIA switch-configurable voltage: 0...10 V DC 24 V max, impedance: 30000 Ohm, resolution 10 bitsVIB configurable voltage: 0...10 V DC 24 V max, impedance: 30000 Ohm, resolution 10 bitsVIB configurable PTC probe: 0...6 probes, impedance: 1500 OhmVIA switch-configurable current: 0...20 mA, impedance: 250 Ohm, resolution 10 bits |
Ambient air temperature for storage | -25…70 °C |
Type of cable | Without mounting kit: 1 wire(s)IEC cable at 45 °C, copper 90 °C / XLPE/EPRWithout mounting kit: 1 wire(s)IEC cable at 45 °C, copper 70 °C / PVCWith UL Type 1 kit: 3 wire(s)UL 508 cable at 40 °C, copper 75 °C / PVC |
Type of polarization | No impedance |
Motor power kW | 2.2 kW |
Variable speed drive application selection | Building - HVAC compressor for scrollBuilding - HVAC fanBuilding - HVAC pump |
Ask for the Pricing of Schneider Altivar 212 2.2kW 3 Phase Drive ATV212HU22N4 at unbeatable prices. Detailed Specifications of ATV212HU22N4 features minimum switching current of 3 mA at 24 V DC for configurable relay logic. The switching frequency is adjustable between 6...16 kHz adjustable12...16 kHz with derating factor. The sensor operates within a supply voltage range of 323…528 V and maintains an operating position with a Vertical +/- 10 degree. It supports a speed range of 1…10 and is powered by a rated supply voltage [Us] of 380...480 V - 15...10 % tolerance. The supply frequency is 50...60 Hz - 5...5 %. This sensor integrates seamlessly with Variable speed drive, offering optimal performance at 12 kHz. Now's the Time to Secure a Quote for your requirement of Schneider Altivar 212 2.2kW 3 Phase Drive. We're committed to offering more favorable pricing and more responsive support than other Traders.