Tecnhical specifications of Sick 24 Voltage Safe Signal Processing SRB-E-602EM 103041589:
Spec | Value |
---|---|
Mounting | Snaps onto standard DIN rail to EN 60715 |
Termination | rigid or flexible, Screw connection, plug-in |
Width | 22.5 mm |
Height | 98 mm |
Depth | 115 mm |
Specification | Value |
---|---|
Housing material | Glass-fibre reinforced thermoplastic, ventilated |
Gross weight | 269 g |
PFH value, Stop 0 | 2.00 x 10⁻⁸ /h |
Mounting | Snaps onto standard DIN rail to EN 60715 |
Termination | rigid or flexible, Screw connection, plug-in |
Cable section, minimum | 0.25 mm² |
Cable section, maximum | 2.5 mm² |
Tightening torque of Clips | 0.5 Nm |
Width | 22.5 mm |
Height | 98 mm |
Depth | 115 mm |
Degree of protection of the enclosure | IP40 |
Degree of protection of the mounting space | IP54 |
Degree of protection of clips or terminals | IP20 |
Ambient temperature | -25 ... +60 °C |
Storage and transport temperature | -40 ... +85 °C |
Resistance to vibrations | 10...55 Hz, Amplitude 0.35 mm, ± 15 % |
Restistance to shock | 10 g / 11 ms |
Rated impulse withstand voltage Uimp | 4 kV |
Frequency range | 50 Hz, 60 Hz |
Operating voltage | 24 VAC -15 % / +10 %24 VDC -15 % / +20 % |
Ripple voltage | 10 % |
Rated operating voltage | 24 VDC |
Electrical power consumption | 4.9 VA |
Contact resistance, maximum | 0.1 Ω |
Drop-out delay, maximum | 35 ms |
Pull-in delay at automatic start, maximum, typically | 20 ms |
Material of the contacts, electrical | Ag-Ni, self-cleaning, positive drive |
Switching capacity, minimum | 10 mA |
Switching capacity, maximum | 2 A |
Conduction resistance, maximum | 40 Ω |
Get A Quote for Sick 24 Voltage Safe Signal Processing SRB-E-602EM part no: 103041589 at the best price. Here are the brief Technical Specifications of SRB-E-602EM, 103041589 are Glass-fibre reinforced thermoplastic, ventilated design, ensuring robust protection and longevity. The sensor is easy to install, Snaps onto standard DIN rail to EN 60715 and the Termination is handled via rigid or flexible, Screw connection, plug-in methods, allowing for both rigid or flexible wiring options. With dimensions of 22.5 mm in Width, 98 mm in Height, and 115 mm in Depth, this compact sensor fits seamlessly into various setups. It operates within a Frequency range of 50 Hz, 60 Hz with an Operating voltage of 24 VAC -15 % / +10 %24 VDC -15 % / +20 %. The Rated operating voltage is 24 VDC and the Electrical power consumption is minimal at just 4.9 VA. It's Time to get a Quote for your requirement of Sick 24 Voltage Safe Signal Processing. We guarantee unmatched pricing and unparalleled support compared to other Distributors.