Phoenix REL-MR-110DC/21-21/EX Single Relay

The Phoenix REL-MR-110DC/21-21/EX Single Relay (Part No: 2908824 ) offers a 110 V DCnominal input voltage UN, 71.5 V DC ... 272.8 V DC input voltage range, 250 V AC/DC switching voltage, Plug / solder connection method. Manufactured by Phoenix under the Phoenix Single Relay category, this model belongs to the Phoenix REL Series.

BrandPhoenix Contact
Product TypeSingle Relay
Model NumberREL-MR-110DC/21-21/EX

Phoenix REL-MR-110DC/21-21/EX Single Relay – Technical Specifications

SpecificationValue
Product typeSingle relay
Mechanical service life3x 107 cycles
InsulationBasic insulation
Overvoltage categoryIII
Pollution degree3
Service life electricalsee diagram
Maximum power dissipation for nominal condition0.45 W
Test voltage (Winding/contact)5 kV AC (50 Hz, 1 min., winding/contact)
Nominal input voltage UN110 V DC
Input voltage range71.5 V DC ... 272.8 V DC
Drive and functionmonostable
Drive (polarity)non-polarized
Typical input current at UN4.1 mA
Typical response time7 ms
Typical release time3 ms
Contact switching type2 changeover contacts
Type of switch contactSingle contact
Contact materialAgNi
Maximum switching voltage250 V AC/DC
Minimum switching voltage5 V (at 10 mA)
Limiting continuous current8 A
Maximum inrush current25 A (20 ms)
Min. switching current10 mA (At 5 V)
Interrupting rating (ohmic load) max.190 W (at 24 V DC)
Connection methodPlug / solder connection
Width12.7 mm
Height29 mm
Depth15.7 mm
Degree of protectionRT III
Ambient temperature (operation)-40 °C ... 85 °C
Ambient temperature (storage/transport)-40 °C ... 85 °C
Standards/regulationsIEC 60664
Mounting positionany
Coil resistance26600 Ω ±15 % (at 20 °C)
Switching capacity2 A (at 24 V, DC13)
Call us for Phoenix RT III Sealed Single Relay REL-MR-110DC/21-21/EX part no: 2908824 at the best rates. Technical Attributes of REL-MR-110DC/21-21/EX, 2908824 are mechanical service life of 3x 107 cycles, designed for demanding industrial applications. The sensor operates at a nominal input voltage of 110 V DC, with an input voltage range of 71.5 V DC ... 272.8 V DC. The typical input current at UN is 4.1 mA with a response time of 7 ms. The sensor supports a maximum switching voltage of 250 V AC/DC, and a minimum switching voltage of 5 V (at 10 mA). It has a limiting continuous current of 8 A, with a maximum inrush current of 25 A (20 ms), and a minimum switching current of 10 mA (At 5 V). The interrupting rating for ohmic loads is 190 W (at 24 V DC). The connection method is via a Plug / solder connection, with a degree of protection rated at RT III. The sensor operates reliably in ambient temperatures ranging from -40 °C ... 85 °C. Unlock Exclusive Pricing with a Quote for your requirement of Phoenix RT III Sealed Single Relay. Trust in our ability to provide more advantageous pricing and dedicated support beyond other other Dealers.