PLC-RSC-230UC/21HC/MS: 2910518 - Phoenix Relay with 1 Changeover
Technical Specifications of Phoenix Relay with 1 Changeover PLC-RSC-230UC/21HC/MS 2910518:
Spec | Value |
---|---|
Product type | Relay Module |
Nominal input voltage UN | 230 V AC |
Connection method | Screw connection |
Mounting type | DIN rail mounting |
Phoenix 230VAC Input Relay EMG 22-REL/KSR-230/21/ SO46, 2940760 Technical Specifications:
Specification | Value |
---|---|
Product type | Relay Module |
Product family | PLC-INTERFACE |
Application | Palm switch |
Mechanical service life | 5x 106 cycles |
Insulation | Safe isolation, reinforced insulation |
Overvoltage category | III |
Pollution degree | 2 |
Maximum power dissipation for nominal condition | 1.15 W |
Test voltage (Winding/contact) | 4 kVrms (50 Hz, 1 min., winding/contact) |
Test voltage (Changeover contact/changeover contact) | - |
Rated surge voltage | 6 kV |
Nominal input voltage UN | 230 V AC |
Input voltage range | 207 V AC ... 264.5 V AC (20 °C) |
Drive and function | monostable |
Drive (polarity) | polarized |
Typical input current at UN | 5 mA |
Typical response time | 6 ms (220 V DC) |
Typical release time | 8 ms (220 V DC) |
Protective circuit | Bridge rectifier; Bridge rectifier |
Operating voltage display | Yellow LED |
Contact switching type | 1 changeover contact |
Type of switch contact | Single contact |
Contact material | AgNi |
Maximum switching voltage | 250 V AC/DC (The separating plate PLC-ATP should be installed for voltages larger than 250 V (L1, L2, L3) between identical terminal blocks in adjacent modules. Potential bridging is then carried out with FBST 8-PLC... or ...FBST 500...) |
Limiting continuous current | 10 A |
Maximum inrush current | 24 A (20 ms) |
Min. switching current | 10 mA (12 V) |
Interrupting rating (ohmic load) max. | 264 W (24 V DC) |
Switching capacity | 2 A (24 V, DC13) |
Connection method | Screw connection |
Stripping length | 8 mm |
Conductor cross section rigid | 0.14 mm² ... 2.5 mm² |
Conductor cross section flexible | 0.14 mm² ... 2.5 mm² |
Conductor cross section AWG | 26 ... 14 |
Tightening torque | 0.6 Nm ... 0.8 Nm |
Width | 14 mm |
Height | 80 mm |
depth | 104 mm |
Color | gray (RAL 7042) |
Flammability rating according to UL 94 | V0 (Housing) |
Degree of protection (Relay) | RT II (Relay) |
Degree of protection (Relay base) | IP20 (Relay base) |
Ambient temperature (operation) | -40 °C ... 50 °C |
Ambient temperature (storage/transport) | -20 °C ... 85 °C |
Temperature | D |
Humidity | A |
Vibration | B/C |
EMC | B |
Enclosure | Required protection according to the Rules shall be provided upon installation on board |
Low Voltage Directive | Conformance with Low Voltage Directive |
Electromagnetic compatibility | Conformance with EMC directive |
Standards/regulations | IEC 60947-5-1 |
Mounting Type | DIN rail mounting |
Mounting position | any |
Contact Connection type | - |
Output fuse | - |
Degree of protection (Installation location) | ≥ IP54 (Installation location) |
Ask for the Pricing of Phoenix Relay with 1 Changeover PLC-RSC-230UC/21HC/MS part no: 2910518 at unbeatable prices. Detailed Specifications of PLC-RSC-230UC/21HC/MS, 2910518 feature Relay Module type and PLC-INTERFACE Product family a versatile solution for Palm switch applications. This relay module features a mechanical service life of 5x 106 cycles, ensuring durability and reliability. With a maximum power dissipation of 1.15 W, it operates efficiently at a nominal input voltage of 230 V AC, within an input voltage range of 207 V AC ... 264.5 V AC (20 °C). The module has a typical input current of 5 mA at UN, with a response time of 6 ms (220 V DC) and a release time of 8 ms (220 V DC). It is equipped with a Bridge rectifier; Bridge rectifier for protection and includes 1 changeover contact made from Screw connection Connection method. Now's the Time to Secure a Quote for your requirement of Phoenix Relay with 1 Changeover. We're committed to offering more favorable pricing and more responsive support than other Traders.