Technical Specifications of Omron 8 Digits,100 to 240 VAC Counter H7HP-C8:

SpecValue
FunctionTotal Counter, Time Counter
Rated Supply Voltage100 to 240 VAC 50/60 Hz
Count Range-99999 to 999999
Max Counting Speed30 Hz/5 kHz (switching)

Omron 8 Digits,100 to 240 VAC Counter H7HP-C8 Technical Specifications:

SpecificationValue
FunctionTotal Counter, Time Counter
Rated Supply Voltage100 to 240 VAC 50/60 Hz
Operating Voltage Range85 to 110% of the power supply voltage
Power Consumption6.5 VA max.
External Power Supply12 VDC 50 mA
Count range-99999 to 999999
Max Counting Speed30 Hz/5 kHz (switching)
Counter Input ModeIncrement/decrement (UP/DOWN (individual input))
Reset SystemExternal and manual reset
Time Counter Ranges-
Counter Time Ranges-
Time counter Set value read selector-
Time counter Reset system-
Input signalCount 1/start, Count 2/gate, Reset, Key protect
Input methodNo-voltage (NPN, contact input)/Voltage input (PNP) selectable
No-voltage input (No-contact input)Short-circuit (ON) impedance: 1 kΩ max. Residual voltage: 2 V max.DC Open circuit impedance: 100 kΩ min.
No-voltage input (Contact input)Short-circuit (ON) impedance: 1 kΩ max. Short-circuit (ON) residual voltage: 2 VDC max. Open circuit impedance: 100 kΩ min.
Voltage inputHight level: 9 to 24 VDC (ON voltage) Low level: 5 VDC max. (OFF voltage) Short-circuit (ON) impedance: 1 kΩ max. Open circuit impedance: 100 kΩ min.
Display method7-segment backlit negative transmissive Red LCD
Display Digits8 digit
Memory backup methods Ambient humidity (Operating) Insulation resistanceMethod: EEP-ROM, Number of rewite: 200,000 operations min., Store data: 20 years min.
Ambient temperature (Storage)-10 to 55 ℃ (with no icing)
Ambient temperature (Operating)-25 to 65 ℃ (with no icing)
Ambient humidity (Operating)35 to 85 %
Insulation resistance100 MΩ min. (at 500 VDC)
Dielectric withstand voltageBetween current carrying terminals and exposed non-current carrying metal parts: 2000 VAC 50/60 Hz 1 min Between power terminals and control input terminals: 2000 VAC 50/60 Hz 1 min
Impulse withstand voltageBetween power terminals: 3.0 kV Between current carrying terminals and exposed non-current carrying metal parts: 4.5 kV
Noise immunityBetween power terminals: ±1.5 kV Between input terminals: ±480 V square-wave noise by noise simulator (pulse width: 100 ns/1 µs, 1-ns rise)
Static immunityDisplay: Mulfunction: 8 kV, Destruction: 15 kV Dip switch: Mulfunction: 4 kV, Destruction: 8 kV
Vibration resistanceDestruction: 10 to 55 Hz, 0.75 mm single amplitude each in 3 directions for 2 h Malfunction: 10 to 55 Hz, 0.5 mm single amplitude each in 3 directions for 10 min
Shock resistanceDestruction: 294 m/s2, 3 times each in 3 axes each directions Malfunction: 196 m/s2, 3 times each in 3 axes each directions
Degree of protectionCase front: IP66 Oil-resistant type and NEMA Type 4 (indoors)
External connection methodScrew terminal
Case colorGray smoke (Front: Light gray (Munsell 5Y7/1))
WeightApprox. 115 g
Obtain a Quote for Omron 8 Digits,100 to 240 VAC Counter, H7HP-C8 at attractive prices. Core System Specifications of H7HP-C8 are 30 Hz/5 kHz (switching), -99999 to 999999, 6.5 VA max., 12 VDC 50 mA. It functionality Includes Total Counter, Time Counter, 100 to 240 VAC 50/60 Hz, 85 to 110% of the power supply voltage. Elevate Your Project with a Quote for your requirement of Omron 8 Digits,100 to 240 VAC Counter. Count on us for more economical pricing and more reliable support than other Dealers & Distributors.