+91 79955 44066
IndMALL: B2B Marketplace - We Connect Buyers & Sellers for Industrial Products

Omron H7HP-A Counter

The Omron H7HP-A Counter combines totalizing and time-counting capability with a wide 100 to 240 VAC supply, offering flexibility for industrial automation. It supports 30 Hz and 5 kHz counting speeds, along with UP/DOWN input modes for versatile operation. Its 6-digit red backlit LCD ensures clear visibility, while external and manual reset options add convenience. The unit delivers IP66 oil-resistant protection, excellent noise immunity, and long-term memory retention through reliable EEPROM storage. Manufactured by Omron and listed under Omron Counter products, this model belongs to the Omron H7HP Series.

BrandOmron
ProductCounters
Model NumberH7HP-A

Omron H7HP-A Counter - Technical Specifications

SpecificationValue
FunctionTotal Counter, Time Counter
Rated supply voltage100 to 240 VAC 50/60 Hz
Operating voltage range85 to 110% of the power supply voltage
Power consumption6.5 VA max.
External power supply12 VDC 50 mA
Count range-99999 to 999999
Max. counting speed30 Hz/5 kHz (switching)
Counter Input modeIncrement/decrement (UP/DOWN (individual input))
Reset systemExternal and manual reset
Input signalCount 1/start, Count 2/gate, Reset, Key protect
No-voltage input (Contact input)Short-circuit (ON) impedance: 1 kΩ max. Short-circuit (ON) residual voltage: 2 VDC max. Open circuit impedance: 100 kΩ min.
Voltage inputHight level: 9 to 24 VDC (ON voltage) Low level: 5 VDC max. (OFF voltage) Short-circuit (ON) impedance: 1 kΩ max. Open circuit impedance: 100 kΩ min.
Display method7-segment backlit negative transmissive Red LCD
Display Digits6 digit
Memory backup methodsMethod: EEP-ROM, Number of rewite: 200,000 operations min., Store data: 20 years min.
External connectionsScrew terminal
Counter Reset systemExternal and manual reset
Input modeNo-voltage (NPN, contact input)/Voltage input (PNP) selectable
Time counter rangesCumulative
counter Time ranges0.1 h to 99999.9 h/1 s to 99 h 59 min 59 s
Time counter Set value read selector±100 ppm (-10 to +55 ℃)
Ambient temperature (Storage)-10 to 55 ℃ (with no icing)
Ambient humidity (Operating)35 to 85 %
Dielectric withstand voltageBetween current carrying terminals and exposed non-current carrying metal parts: 2000 VAC 50/60 Hz 1 min Between power terminals and control input terminals: 2000 VAC 50/60 Hz 1 min
Impulse withstand voltageBetween power terminals: 3.0 kV Between current carrying terminals and exposed non-current carrying metal parts: 4.5 kV
Noise immunityBetween power terminals: ±1.5 kV Between input terminals: ±480 V square-wave noise by noise simulator (pulse width: 100 ns/1 µs, 1-ns rise)
Static immunityDisplay: Mulfunction: 8 kV, Destruction: 15 kV Dip switch: Mulfunction: 4 kV, Destruction: 8 kV
Vibration resistance100 MΩ min. (at 500 VDC)
Shock resistanceDestruction: 294 m/s2, 3 times each in 3 axes each directions Malfunction: 196 m/s2, 3 times each in 3 axes each directions
Degree of protectionCase front: IP66 Oil-resistant type and NEMA Type 4 (indoors)
Case colorGray smoke (Front: Light gray (Munsell 5Y7/1))
WeightApprox. 115 g